5151 San Felipe Suite 500 Houston, TX 77056 www .goodmanmfg.com • www .amana-hac.com © 2009-2011 Goodman Manufacturing Company , L.P . I NST ALLA TION I NSTRUCTIONS FOR *CVC9/95 & *MVC95 - T WO.
2 S HIPPING I NSPECTION ........................................................................................................................................... 6 E LECTROST A TIC D ISCHARGE (ESD) P RECAUTIONS ......................................
3 Gas Supply and Piping .......................................................................................................... .......................... 3 0 H IGH A L TITUDE D ERA TE ...............................................................
4 G OOD MA N WILL NOT BE RE SP O NSI B LE FOR ANY INJURY OR PROP E RTY DAMAGE ARISING FROM IMPROPER SERVIC E OR SERVIC E PROC EDURE S .
5 Adhere to the following warnings and cautions when installing, adjusting, altering, servicing, or operating the furnace. T o e nsure proper installation and operation, thoroughly read this manual for specifics pertaining to the installation and application of this product.
6 S HIPPING I NSPECTION All units are securely packed in shipping containers tested ac- cording to International Safe T ransit Association specifications. The carton must be checked upon arrival for external damage. If damage is found, a request for inspection by carrier’s agent must be made in writing immediately .
7 T O PREVEN T PROP ERTY DAMAGE , PER SONAL INJURY OR DEATH DUE TO FIRE , DO NOT INST A LL THI S FUR NAC E IN A MOBILE HOME , TR AIL ER , OR RE CR EATI O N AL VE HICL E .
8 A copy of the National Fuel Gas Code (NFP A 54/ANSI Z223.1) can be obtained from any of the following: American National Standards Institute 1430 Broadway New Y ork, NY 10018 National Fire Protectio.
9 • If the furnace is used in connection with a cooling coil unit, install the furnace upstream or in parallel with the cooling coil unit. Premature heat exchanger failure will result if the cooling unit is placed ahead of the furnace.
10 • Concealed hot or cold water pipes, or chimneys. • Unconditioned areas behind the thermostat, such as an outside wall. Consult the instructions packaged with the thermostat for mounting instructions and further precautions.
11 H ORIZONT AL A PPLICA TIONS & C ONSIDERA TIONS Horizontal applications, in particular , may dictate many of the installation’s specifics such as airflow direction, ductwork connec- tions, flue and combustion air pipe connections, etc.
12 A LTERNATE E LECTRICAL AND G AS L INE C ONNECTIONS This furnace has provisions allowing for electrical and gas line con- nections through either side panel. In horizontal applications the connections can be made either through the “top” or “bottom” of the furnace.
13 T O AVOID BOD ILY INJURY , FIRE OR EXPLO SION , SOL VENT CEME NT S MUST BE KE P T AWA Y FROM ALL IGNITION SOUR CES ( I . E ., SPAR KS , OP EN FLA MES , AND EX CESSIV E HEAT ) AS THE Y ARE CO MB U STIBL E LIQUIDS .
14 vicing. Combustion Air and V ent piping should be routed in a man- ner to avoid contact with refrigerant lines, metering devices, con- densate drain lines, etc. If necessary , clearances may be in- creased by utilizing two 45 deg. Long-Sweep Elbows and creat- ing an “S” joint to provide additional space at connection loca- tions.
15 RUBBER COU PLING WIT H WOR M GEAR C LAM PS RUBBE R COUPLINGS WITH W ORM GEAR CL AMPS COMBUSTION AIR PI PE ( D IR ECT VENT O NL Y) COMBUSTION AIR PIPE (DI REC T VE N T ON LY) VENT/FLUE PIPE VENT/FLU.
16 8. Upflow and Counterflow units . For horizontal installations , externally secure the field- supplied vent/flue pipe directly to the vent/flue coupling using a PVC or ABS coupling or elbow .
17 N ON -D IRECT V ENT (S INGLE P IPE ) P IPING Non-direct vent installations require only a vent/flue pipe. The vent pipe can be run horizontally with an exit through the side of the building or run vertically with an exit through the roof of the building.
18 V ENT /F LUE P IPE T ERMINATIONS The vent/flue pipe may terminate vertically , as through a roof, or horizontally , as through an outside wall. V ertical vent/flue pipe terminations should be as shown in the fol- lowing figure. Refer to Vent/Flue Pipe and Combustion Air Pipe - T ermination Locations for details concerning location restrictions.
19 If the combustion air intake pipe is to be installed above a finished ceiling or other area where dripping of condensate will be objec- tionable, insulation of the combustion air pipe may be required. Use 1/2” thick closed cell foam insulation such as Armaflex™ or Insultube™ where required.
20 24" MAX 3" MIN 24" MAX A IR INT A KE 12” MIN SCREEN (OPTIONAL) 90 º ME DI UM RADIUS ELBOWS Alternate Horizontal Vent Termination (Dual Pipe) _______________________ SUP PORT STRAPS V ENT/ FLUE TEE 12" MIN . A BOVE HIGHEST ANTICIP A TED SNO W LEV EL 12" MIN .
21 C ONDENSA TE D RAIN L INES & D RAIN T RAP A condensing gas furnace achieves its high level of efficiency by extracting almost all of the heat from the products of combustion and cooling them to the point where condensation takes place. The condensate which is generated must be piped to an appropri- ate drain location.
22 U PRIGHT I NSTALLATIONS -T RAP ON R IGHT S IDE In a upright installation drain hoses are connected to drain ports on the rubber elbow and the recuperator coil front cover . The drain lines are then routed through the right side panel and into the drain trap secured to the outside of the cabinet.
23 A LTERNATE V ENT /F LUE D RAIN H OSE C ONNECTIONS Upright installations using the alternate vent/flue outlet will require “right-side only” drain hoses to be connected as follows. Refer to Vent/Flue Pipe and Combustion Air Pipe for details on alternate vent/flue pipe connection .
24 U PRIGHT I NSTALLATIONS -T RAP ON L EFT S IDE NOTE: For left side trap installation, grommets must be moved to the left side of the furnace and the plugs installed on the right side of the furnace. 1. Remove the rubber plug/cap from the left side drain port on the front cover .
25 U PRIGHT D RAIN T RAP M OUNTING (L EFT OR R IGHT S IDE P ANEL ) 1. Insert drain tubes into drain trap and position the drain trap against the side panel.
26 L EFT S IDE D OWN Horizontal installations with the left side panel down will require drain hoses to be connected to the left side front cover drain port and the side drain port on the rubber elbow . 1 . Remove the rubber plug/cap from the front cover left (down) side drain port.
27 E LECTRICAL C ONNECTIONS HIG H VO L T A G E ! T O AVOID THE RIS K OF ELECT RICAL SHOCK , WIRING TO THE UNIT MUST BE POL ARIZE D AND GROUN DED .
28 1 . Measure resistance between the neutral (white) connection and one of the burners. 2. Resistance should measure 10 ohms or less. This furnace is equipped with a blower door interlock switch which interrupts unit voltage when the blower door is opened for servicing.
29 T o use a single-stage thermost at, turn of f power to the furnace, move the thermostat selection DIP switch to the OFF position. Set the desired transition time by setting the transition delay DIP switch to the desired ON/OFF position. Turn power back on.
30 Accessories Wiring If it is necessary for the installer to supply additional line voltage wiring to the inside of the furnace, the wiring must conform to all local codes, and have a minimum temperature rating of 105°C. All line voltage wire splices must be made inside the furnace junction box.
31 Consult the furnace S pecification Sheet for a listing of appropri- ate kits. The indicated kits must be used to insure safe and proper furnace operation.
32 MANUAL SHU T O FF VALVE (UP ST R EA M FROM PI PE UNION) GRO M ME T IN STA NDA RD GAS L INE HO LE G AS L IN E PL U G I N G AS L IN E HOLE HEI G HT REQ UIR ED BY LO CA L CODE PIPE UNION DRI P L EG MA.
33 D IRECT /S TANDARD I NLET P IPING E DGES OF SHEET META L HOLES MAY BE SHARP . U SE GLOVES AS A PRE CAUT ION WHEN RE MO V IN G HOLE PLUGS .
34 3/8" 1/2" 5/8" 3/4" 7/8" 1/2" 3/4" 10 730 1,700 3,200 5,300 8,300 3,200 7,500 20 500 1,100 220 3,700 5,800 2,200 4,200 30 400 920 2,000 2,900 4,700 1,800 4,000 40.
35 Checking Static Pressure (80% Furnace Shown, 90% Similar) B OTTOM R ETURN A IR O PENING [U PFLOW M ODELS ] The bottom return air opening on upflow models utilizes a “lance and cut” method to remove sheet metal from the duct opening in the base pan.
36 600 80 0 100 0 12 00 1 400 160 0 20 00 045 3__ XA 37 6* 38 4 4 80 576 - -- -- - - -- 07 0 4 _ _ XA --- --- 62 7 * 6 2 7 * 67 2 768 --- 090 5__ XA -- - --- - -- 83 6* 8 36* 836 * 960 115 5__ XA -- -.
37 H EAT A NTICIPATOR S ETTING The heat anticipator in the room thermostat must be correctly adjusted to obtain the proper number of cycles per hour and to prevent “overshooting” of the setting. Set the heat anticipator set- ting to 0.7 amps. Follow the thermostat manufacturer’s instruc- tions on how to adjust the heat anticipator setting.
38 i M a n o m e t e r M a n o m e t e r H o s e Com mon T e rm inal (C) Hig h Fi re Coi l T erminal ( HI) Low Fire Coil T erminal ( LO) Inlet Pressure T ap 1/8 NPT O p e n t o A t m o s p h e r e Outlet Pressure T ap 1/8 NPT Honeywell Model VR9205 Connected to Manometer 1.
39 9. Close thermostat “R” and “W2” contacts to provide a call for high stage heat. 1 0. Remove regulator cover screw from the high (HI) outlet pressure regulator adjust tower and turn screw clockwise to increase pressure or counterclockwise to decrease pressure.
40 RISE = SU PP LY AIR RET UR N AIR HEA T EXCH A NGE R RADIA TION "L INE OF S IGHT" T RETURN T SUPPLY T SU PPL Y - T RETURN Temperature Rise Measurement C IRCULATOR B LOWER S PEEDS T O A.
41 OFF 100% CFM 100% CFM 1 min OFF • Profile B ramps up to full cooling demand airflow by first stepping up to 50% of the full demand for 30 seconds. The motor then ramps to 100% of the required airflow . A one (1) minute OFF delay at 100% of the cooling airflow is provided.
42 7. Select the heating speed for your model from the heating speed chart in the S pecification Sheet. The adjust setting (already established by the cooling speed selection) determines which set of speeds are available. The selected speed must provide a temperature rise within the rise range listed with the particular model.
43 Sy st em S y st em O p e r a ti n g Mo d e Ai r f l ow De ma nd So ur c e Co o l i ng A i r Co nd it io n er H eat i n g F ur na ce C on ti nuo us F a n T he r m osta t C oo lin g H ea t P u mp H e.
44 12 R C 12 RC CTK0 *AA Th er most at Comfor tNet Compatible Furnace Int egrated Contr ol Mo dul e Comfor tNet Compati ble AC/H P Int egra ted Contr ol Mo dul e 40V A Tra nsf or mer (included i n CTK.
45 F URNACE A DVANCED F EATURES M ENUS S ubm e nu I t em I ndi c a t i on ( f o r D i s pl ay On ly; not Us er Mod if i able) N um ber of Heat S tages (HT STG ) Disp l ay s t he number of fur nace hea.
46 T HERMOSTAT M ENU If this furnace is installed with a c ommunicating compatible heat pump, the system is recognized as a dual fuel system. The balance point temperature should be set via the thermostat ad- vanced menu. Navigate to the THERMOST A T menu.
47 S YSTEM T ROUBLESHOOTING NOTE: Refer to the instructions accompanying the ComfortNet compatible outdoor AC/HP unit for troubleshooting information. Refer to the Troubleshooting Chart in the back of this manual fo r a listing of possible furnace error codes, possible causes and corrective actions.
48 • Integrated control module performs safety circuit checks. • Induced draft blower is energized on high speed for a 15- second prepurge. Humidifier terminal is energized with induced draft blower . • Induced draft blower steps to low speed following prepurge.
49 O PERA TIONAL C HECKS The burner flames should be inspected with the burner compart- ment door installed. Flames should be stable, quiet, soft, and blue (dust may cause orange tips but they must not be yellow). Flames should extend directly outward from the burners without curling, floating, or lifting off.
50 R ESETTING F ROM L OCKOUT Furnace lockout results when a furnace is unable to achieve igni- tion after three attempts during a single call for heat. It is charac- terized by a non-functioning furnace and a E E E E E 0 0 0 0 0 code displayed on the dual 7-segment display .
51 C ONDENSATE T RAP AND D RAIN S YSTEM (Q UALIFIED S ERVICER O NLY ) Annually inspect the drain tubes, drain trap, and field-supplied drain line for proper condensate drainage. Check drain system for hose connection tightness, blockage, and leaks. Clean or repair as necessary .
52 123456789 1 0 9 0 s econ d s O F F OF F --- --- --- --- --- --- --- --- 12 0 seco n ds O N O F F --- --- --- --- --- --- --- --- 150 s ec onds * OF F ON -- - - - - - - - -- - - - - - - - - - - -- -.
53 T ROUBLESHOOTING C HART ComfortNet Thermostat Only Symptoms of Abnor mal Operation (Non-Communicating & Com fortNet™ Thermostat) Diagnostic /Status LED Codes Fault Description Message Code Possible Cau ses Corrective Actions Notes & Cautions x Furnace fails to operate x Integrated c ontrol m odule LED display provides n o signal.
54 T ROUBLESHOOTING C HART ComfortNet Thermostat Only Symptoms of Abnor mal Operation (Non-Communicating & ComfortNet™ Thermostat Diagnostic /Status LED Codes Fault Description Message Code Possible Cau ses Corrective Actions Notes & Cautions x Circulator blower runs continuously.
55 T ROUBLESHOOTING C HART ComfortNet Thermostat On ly Symptoms of A bnormal Operation (Non-Communicating & ComfortNet™ Thermostat Diagnostic /Status LED Codes Fault Description Message Code Possible C auses Corrective Actions Notes & Cautio ns x Furnace fails to operate on high stage; furnace operates normally on low stage.
56 T ROUBLESHOOTING C HART ComfortNetThermostat Only Symptoms of A bnormal Operation (Non-Communicating & Com fortNet™ Thermostat Diagnostic /Status LED Codes Fault Description Message Code Possible Cau ses Corrective Actions Notes & Cautions x Operation different than expected or no operation.
57 T ROUBLESHOOTING C HART ComfortNet Thermostat On ly Symptoms of A bnormal Operation (Non-Communicating & ComfortNet™ Thermostat Diagnostic /Status LED Codes Fault Description Message Code Possible Cau ses Corrective Actions Notes & Ca utions x Furnace fails to operate.
58 S T A TUS C ODES C 2 H I b 0 d 4 C 1 b 2 E 4 H I INT ERNAL CONTROL F AUL T/NO POW ER N O RMAL OP E R ATIO N LOCKOUT DUE T O EXCESSIVE RETRIES LOW S T A GE PRESSUR E SWI T CH STUCK C LOSED A T ST A .
59 NO FUSE 3 A 1. SE T HE A T ANTI CIPATOR ON R OO M T HE RM O STAT AT 0 .7 AMP S . YL MA NU A L RE S ET AUX I LIAR Y LI MIT CONTR OL PK WA R NING:DISCO NNECT TO MICR O ID 40 V A TRANSF ORMER PU GY N NEUTRAL BL WIRING T O UNIT 10 DE HU M 3 O NO PK DIA G NO STIC LE D' S BR 4.
60 HIGH VOL T AGE! Disconnect ALL power be f ore s ervicing or i nstalling t his unit . Multiple power sources m ay be present. Fai lure to do so may cause property damage, p er sonal injur y or de ath. Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Goodman CVC9/95 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Goodman CVC9/95 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Goodman CVC9/95 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Goodman CVC9/95 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Goodman CVC9/95, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Goodman CVC9/95.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Goodman CVC9/95. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Goodman CVC9/95 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.