Manuale d’uso / di manutenzione del prodotto P218-5100 del fabbricante Giant
Vai alla pagina of 16
Contents: Installation Instructions: page 2 Pump Specifications: pages 3- 9 Exploded View: page 10 Parts List / Kits: page 11 Torque Specifications: page 11 Repair Instructions : pages 12-13 Pump moun.
2 INSTALLATION INSTRUCTIONS 4. Use of a dampener is necessary to minimize pulsation at drive elements, plumbing, connec- tions, and other system areas. The use of a dampener with Giant Industries, Inc. pumps is optional, although recommended by Giant Industries, Inc.
3 Specifications Model P217A-3100/5100 Consult the factory for special requirements that must be met if the pump is to operate beyond one or more of the limits specified above. U.S. (Metric) 1750 RPM + Ratings .........................................
4 Consult the factory for special requirements that must be met if the pump is to operate beyond one or more of the limits specified above. Specifications Model P218A-3100/5100 U.S. (Metric) V olume ....................................................
5 Specifications Model P219A-3100/5100 Consult the factory for special requirements that must be met if the pump is to operate beyond one or more of the limits specified above. PUMP PULLEY MOTOR PULLEY RPM GPM 800 PSI 1200 PSI 1500 PSI 1700 PSI 2000 PSI 7.
6 Specifications Model P220A-3100/5100 Consult the factory for special requirements that must be met if the pump is to operate beyond one or more of the limits specified above. PUMP PULLEY MOTOR PULLEY RPM GPM 800 PSI 1200 PSI 1500 PSI 1700 PSI 2000 PSI 7.
7 NOTE: In order to drive the pump from the side opposite the present shaft extension, simply remove the valve casing from the crankcase and rotate the pumps 180 degrees to the desired position. Be certain to rotate the seal case (item #20) as well, so that the weep holes are down at the six o'clock position.
8 NOTE: In order to drive the pump from the side opposite the present shaft extension, simply remove the valve casing from the crankcase and rotate the pumps 180 degrees to the desired position. Be certain to rotate the seal case (item #20) as well, so that the weep holes are down at the six o'clock position.
9 NOTE: In order to drive the pump from the side opposite the present shaft extension, simply remove the valve casing from the crankcase and rotate the pumps 180 degrees to the desired position. Be certain to rotate the seal case (item #20) as well, so that the weep holes are down at the six o'clock position.
10 Exploded View - P200A-3100/5100 Series.
11 ITEM PART NO. DESCRIPTION QTY. 1 08300 Crankcase 1 2 08301-0100 Dipstick 1 3 08302 Crankcase Plug Cover 1 3A 07190-0100 Drain Plug & Gasket 1 4 08005 O-Ring 1 5 08185-0100 Oil Drain Plug with seal 1 6 07188-0100 Screw, 316 S.S. 4 6A 07223-0100 Spring Washer, 316 S.
12 REPAIR INSTRUCTION - P200A-3100/5100 SERIES 1. With a 22mm socket wrench, remove the (3) discharge valve plugs and (3) inlet valve plugs (32) Inspect the o-ring (33) for wear and replace if dam- aged. 2. Using a needle nose pliers, remove the inlet and discharge valve assemblies (27-30) and o-ring (31).
13 Disassembly sequence of the back end of the P200A-3100/5100 series pump. 1 ) Before you begin, drain the oil from the crankcase. 2) Remove the crankcase cover (3) and o-ring (4) from the crankcase (1). To remove the crankshaft (13), remove the bearing cover (7) and sight glass (8).
14 Preventative Maintenance Check-List & Recommended Spare Parts List Check Daily Weekly 50hrs Every Every Every 500 hrs 1500 hrs 3000 hrs Oil Level/Quality X Oil Leaks X Water Leaks X Belts, Pull.
15 P200A-3100/5100 DIMENSIONS - INCHES (mm).
GIANT INDUSTRIES LIMITED WARRANTY Giant Industries, Inc. pumps and accessories are warranted by the manufacturer to be free from defects in workmanship and material as follows: 1. For portable pressure washers and car wash applications, the discharge manifolds will never fail, period.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Giant P218-5100 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Giant P218-5100 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Giant P218-5100 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Giant P218-5100 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Giant P218-5100, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Giant P218-5100.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Giant P218-5100. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Giant P218-5100 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.