Seri e s P 200A Updated 6/00 Triplex Ceramic Plunger Pump Operating Instructions/ Repair and Service Manual For Models: P217 P218 P219 P220 P221 P223 Contents: Installation Instructions: page 2 Pump S.
2 INSTALLATION INSTRUCTIONS 4. Use of a dampener is necessary to minimize pulsation at drive elements, plumbing, connec- tions, and other system areas. The use of a dampener with Giant Industries, Inc. pumps is optional, although recommended by Giant Industries, Inc.
3 P217A HORSEPOWER REQUIREMENTS RPM GPM 1000 PSI 1500 PSI 2000 PSI 2500 PSI* 1725 1.7 1.2 1.8 2.4 3.0 3000 3.0 2.1 3.1 4.2 5.2 3200 3.2 2.2 3.3 4.4 5.5 3450 3.
4 NOTE: In order to drive the pump from the side opposite the present shaft extension, simply remove the valve casing from the crank- case and rotate the pumps 180 degrees to the desired position. Be certain to rotate the seal case (item #20) as well, so that the weep holes are down at the six o'clock position.
5 Specifications Model P219A NOTE: In order to drive the pump from the side opposite the present shaft extension, simply remove the valve casing from the crank- case and rotate the pumps 180 degrees to the desired position. Be certain to rotate the seal case (item #20) as well, so that the weep holes are down at the six o'clock position.
6 Specifications Model P220A NOTE: In order to drive the pump from the side opposite the present shaft extension, simply remove the valve casing from the crank- case and rotate the pumps 180 degrees to the desired position. Be certain to rotate the seal case (item #20) as well, so that the weep holes are down at the six o'clock position.
7 Specifications Model P221A V olume ................................................................................................... Up to 2.21 GPM Discharge Pressure ................................................................................
8 Specifications Model P223A V olume ................................................................................................... Up to 3.0 GPM Discharge Pressure ................................................................................ Up to 3000 PSI * Inlet Pressure .
9 ITE M PART NO. DESCRIPTION QTY. 16A 06562 Plunger Base (P223 Only) 3 16B 08455 Plunger Pipe (Excluding P223) 3 16B 07778 Plunger Pipe (P223 Only) 3 16C 08456 Tension Screw 3 16D 07676 Copper Gasket .
10 Exploded View - P200A Series.
11 P200A SERIES REPAIR KITS Plunger Packing Kit Part # 09164 (Excluding P223) Item # Qty. Part # Description 23 3 08477 V-Sleeve, weep 23A 3 08087 V-Sleeve, brown 24 3 07904 Pressure Ring Plunger Packing Kit Part #09525 (P223 Only) Item # Qty. Part # Description 23 6 06315 V -Sleeve 24 3 06920 Pressure Ring Oil Seal Kit Part # 09144 Item # Qty.
12 NOTE: Always take time to lubricate all metal and nonmetal parts with a light film of oil before reassembly. This step will ensure proper fit, at the same time protecting the pump nonmetal parts (i.
13 Reassembly sequence of the P200A series pump 1) If oil seals (19) were removed, replace with seal lip towards crankcase. Lubricate seals before replacing. 2) Replace seal case (20) with o-rings (21) over plungers. Generously lubricate o-rings and oil seal before reassembly.
14 PUMP SYSTEM MALFUNCTION MALFUNCTION The Pressure and/or the Delivery Drops Water in crankcase Noisy Operation Rough/Pulsating Operation with Pressure Drop Pressure Drop at Gun Excessive Leakage Hig.
15 NOTES P200A DIMENSIONS (inches).
GI ANT INDUSTRIES LIMITED WARRANTY Giant Industries, Inc. pumps and accessories are warranted by the manufacturer to be free from defects in workmanship and material as follows: 1. For portable pressure washers and self-serve car wash applications, the discharge manifolds will never fail, period.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Giant P217 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Giant P217 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Giant P217 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Giant P217 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Giant P217, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Giant P217.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Giant P217. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Giant P217 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.