Copyright All Rights Reserved. P-MU-AD425S V er . A Publish:2008.07.1 1 Page: 1/ 20 AD-425S Automatic Door Operator Instruction Manual General Safety Precautions z This instruction manual is intend ed sole ly for use by qualified professionals. All installation s, electrical connections and adjustments must follow the inst allation instructions.
Copyright All Rights Reserved. P-MU-AD425S V er . A Publish:2008.07.1 1 Page: 2/ 20 z Make sure the volt age specified as correct for the device. z Must provide at least 10 seconds rest ti me between every restarting cycle to ensure adequate residual current can be return ed to power system.
Copyright All Rights Reserved. P-MU-AD425S V er . A Publish:2008.07.1 1 Page: 3/ 20 All Packing materials 1. Construction Name ○ 1 C o v e r ○ 2 M o t o r ○ 3 Reducer ○ 4 Square Couplings ○ 5 Control Board ○ 6 Battery ○ 7 Power Switch ○ 8 Operating Arm ○ 9 Sliding Rail ○ 10 S topper Ball ○ 1 1 Baseplate ○ 12 T ransformer 2.
Copyright All Rights Reserved. P-MU-AD425S V er . A Publish:2008.07.1 1 Page: 4/ 20 3. Control Board Guide Input/Output Cont act Explanation Remark Make sure the input is use d corre ctly (AC1 10 or 220V). When turn on the power switch, it enters a learning mode.
Copyright All Rights Reserved. P-MU-AD425S V er . A Publish:2008.07.1 1 Page: 5/ 20 Input/Output Contact Explanation Remark Jumper 1-2 is N.C. cont act. N. C. (default) Jumper 1-3 is N.O. conta ct. N. O. (default) Jumper 1-8 is N.C., or using the “OPEN” switch.
Copyright All Rights Reserved. P-MU-AD425S V er . A Publish:2008.07.1 1 Page: 6/ 20 The opening, closing and maintain -open time illustration table. VM (Opening and Closing T im e Adjustment ) Opening.
Copyright All Rights Reserved. P-MU-AD425S V er . A Publish:2008.07.1 1 Page: 7/ 20 5. S pecification Power Input 1 10V (or 220V) AC , 50-60H z Current (See Figure 2 ) 3.5A max., 0.6A average T orque 30Nm Opening/Closing time (VM) 4.5~9.5 s ( 90° ) Maintain - Op en time (TC) 1~35 seconds Battery S pecification 12V 1.
Copyright All Rights Reserved. P-MU-AD425S V er . A Publish:2008.07.1 1 Page: 8/ 20 Installation instructi ons z Refer to figure 3 for in-swing door (ri ght -hand).
Copyright All Rights Reserved. P-MU-AD425S V er . A Publish:2008.07.1 1 Page: 9/ 20 Figure 5 : For right-hand and out-swing door . F/R switch set 「 ON 」 . Operating Arm mount s to left-side. Figure 6 : For left-hand and out-swing d oor . F/R switch set 「 1 」 .
Copyright All Rights Reserved. P-MU-AD425S V er . A Publish:2008.07.1 1 Page: 10/ 20 z Figure 1 1~13 showing a n operator in stallation of a minimum door leaf wid th and a maximum opening angle. The opening angle is recommend ed not excess to 120 ∘ .
Copyright All Rights Reserved. P-MU-AD425S V er . A Publish:2 008.07.1 1 Page: 1 1/ 20 AD-425S T emplate Installation Instruction Figure 17 Out-swing door (Right-Hand Open) Figure 18 Out-swing door (L.
Copyright All Rights Reserved. P-MU-AD425S V er . A Publish:2008.07.1 1 Page: 12/ 20 Inst allation Step s Out-swing door ( Right-Hand O pen ) S tep Figures Explanation S tep 1. Place the AD-425S template to the right position on the door header . See the figure presented for an out-swing door (Right-Hand Open), more det ails shown in Figure 17.
Copyright All Rights Reserved. P-MU-AD425S V er . A Publish:2008.07.1 1 Page: 13/ 20 S teps Figures Explanation S tep 7. Use Allen Wrench to tighten the Blind Nut. This will compress the sc rew so that it remains permanently fixed in the hole. Repeat these step s on other Blind Nuts.
Copyright All Rights Reserved. P-MU-AD425S V er . A Publish:2008.07.1 1 Page: 14/ 20 S teps Figures Explanation S tep 12. Use Allen Wrench to tighten the Blind Nut. This will compress the sc rew so that it remains permanently fixed in the hole. Repeat these step s on other Blind Nuts.
Copyright All Rights Reserved. P-MU-AD425S V er . A Publish:2008.07.1 1 Page: 15/ 20 S teps Figures Explanation S tep 18. T ighten screws. S tep 19. Insert screws (6 x 95 mm) to the Oper ating Arm on Square See the figure present e d for a out-swing door (Right-Hand Open), more det ails shown in Figure 9.
Copyright All Rights Reserved. P-MU-AD425S V er . A Publish:2008.07.1 1 Page: 16/ 20 S teps Figures Explanation S tep 24. Fix the Sliding Rail on the door leaf. (Screw specification: 6 X 20 mm) S tep 25. Slide in the Sliding Rail Cover . S tep 26. Attach two Side Ends.
Copyright All Rights Reserved. P-MU-AD425S V er . A Publish:2008.07.1 1 Page: 17/ 20 S teps Figures Explanation S tep 30. First opening movement, the AD-425S will b e automatically set the opening angle and dist ance. S tep 31. Attach the cover . S tep 32.
Copyright All Rights Reserved. P-MU-AD425S V er . A Publish:2008.07.1 1 Page: 18/ 20 T rouble shooting Problem Possible Cause Solution No AC power Make sure the Control Board an d fuse are working properly and connected properl y . Motor have no power (LED motor light not on.
Copyright All Rights Reserved. P-MU-AD425S V er . A Publish:2008.07.1 1 Page: 19/ 20 Problem Possible Cause Solution Safety devices are on Contact you r local distributor to check the Photocell and Safety Device. (ke ep the device clean) The door automatically open but doesn’t close.
Copyright All Rights Reserved. P-MU-AD425S V er . A Publish:2008.07.1 1 Page: 20/ 20 General Safety Precautions The following precautions are e ssential for the user . z Read the precaution below carefully as it cont ains imp ortant information about safe inst allation and maintenance.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Gianni Industries AD-425S è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Gianni Industries AD-425S - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Gianni Industries AD-425S imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Gianni Industries AD-425S ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Gianni Industries AD-425S, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Gianni Industries AD-425S.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Gianni Industries AD-425S. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Gianni Industries AD-425S insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.