Manuale d’uso / di manutenzione del prodotto 005210-0 del fabbricante Generac Power Systems
Vai alla pagina of 56
ST ANDBY GENERA T OR O WNER'S MANU AL This manual should remain with the unit. A ne w standar d of reliability Serial Number QT 1.5L 20kW Model: 005210-0 — CAUTION — ONL Y QU ALIFIED ELECTRICIANS OR CONTRA CT ORS SHOULD A TTEMPT INST ALLA TION! DEADL Y EXHA UST FUMES.
Standby Generator Sets T able of Contents SECTION P AGE SAFETY RULES ................................................ 1-1 INTRODUCTION ..................................................... 1-3 Read this Manual Thoroughly ..............................
Study these SAFETY RULES carefully before install- ing, operating or servicing this equipment. Become familiar with this Owner’s Manual and with the unit. The generator can operate safely , efficiently and reli- ably only if it is properly installed, operated and maintained.
• Before performing any maintenance on the gen- erator , disconnect its battery cables to prevent accidental start -up. Disconnect the cable from the battery post indicated by a NEGA TIVE, NEG or (–) first. Reconnect that cable last. • Never use the generator or any of its parts as a step.
1-3 I NTRODUCTION Thank you for purchasing this model of the standby generator set product line. Every effort was expended to make sure that the information and instructions in this manual were both accurate and current at the time the manual was written.
I DENTIF ICA TION R E C OR D D A T A LA BE L Every generator set has a DA T A LABEL that contains important information pertinent to the generator . The data label, which can be found attached to the .
E QUIPM ENT DE SCRI PTION This equipment is a revolving field, alternating cur - rent generator set. It is powered by a gaseous fueled engine operating at 1800 rpm for 4-pole direct drive units, 3600 rpm for 2-pole direct drive units and 2300 - 3000 rpm for quiet drive gear units.
ENGI NE P RO TE CTIVE DEVICE S The standby generator may be required to operate for long periods of time without an operator on hand to monitor such engine conditions as coolant tempera- ture, oil pressure or rpm.
F U E L SYST E M FUE L RE QUIRE MEN T S The standby generator may be equipped with one of the following fuel systems: • Natural gas fuel system • Propane vapor (PV) fuel system The Manual Drawing .
SP E CIF ICA TIONS GEN ERA T OR T ype ............................................................................. Synchronous Rotor Insulation .................................................................... Class F Stator Insulation ...........
COLD WEA THER KIT F or cold climates, optional cold weather kit (part number 0F6148) is recommended. The kit includes: • Battery W armer • 4” Junction Box with hardware • 6 qt. pack 5W -30 synthetic oil (engine) R E C ONF IGU RI NG TH E FU EL SY S TEM NOTE: All models are configured for natural gas or LP vapor from the factory .
GEN ERA T OR A C LEAD C ON NECTIONS See “V oltage Codes”. This generator may be rated at any one of three voltages, either single -phase or three -phase. The electrical wires in the unit ’s A C con- nection (lower) panel should be installed according to the number of leads and the voltage/phase required for the application.
I NS T ALLA TION Refer to the separate “Installation Guide QT Product Line” supplied with the unit. P REP AR A TION BEFOR E ST ART -UP The instructions in this section assume that the standby generator has been properly installed, ser - viced, tested, adjusted and otherwise prepared for use by a competent, qualified installation contractor .
S T ART -U P CH E CKLIS T Before working on the generator , ensure the fol- lowing: • The AUTO/OFF/MANU AL switch is in the OFF position. • The 120V AC supply to the battery charger is switched OFF . P REP AR A TION FOR ST ART -UP • Ensure that the 120V AC circuit breaker to the bat - tery charger is open.
GEN ERA T OR C ONTROL AN D OP ERA TION Refer to the appropriate control panel operator’s manual for this unit. OP ERA TI NG U N IT WITH MAN U AL TR ANSFER SWIT CH If the generator was installed in conjunction with a transfer switch capable of manual operation only , the following procedure applies.
MAI NTENANCE PER FOR M ED B Y AUTHOR IZED SERVICE F ACILITI ES Before working on the generator , ensure the fol- lowing: • The AUTO/OFF/MANU AL switch is in the OFF position. • The 15A fuse has been removed from the con- trol box. • The 120V AC supply to the battery charger is switched OFF .
Figure 10.1 - Oil Dipstick and Oil Fill Cap OIL FILL CAP OIL DIPSTIC K B A TTE R Y FL UID Check battery electrolyte fluid based on the Maintenance Schedule. Fluid should cover separa- tors in all battery cells. If fluid level is low , add dis - tilled water to cover tops of separators.
CHANGI NG ENGIN E OIL Refer to maintenance performed by authorized service facilities for engine oil and filter change frequencies. Drain the oil while the engine is still warm from run- ning . This means warm up the engine, shut it down and drain immediately as follows: 1.
M IS CELLAN EOUS MAINTENANCE CLEAN ING TH E GENER A T OR Keep the generator as clean and as dry as possible. Dirt and moisture that accumulates on internal gen- erator windings have an adverse effect on insulation resistance. P eriodically clean generator exterior surfaces.
SERVICE S CH EDULE The following is a recommended maintenance schedule for small standby and residential generator sets. The established intervals in the schedule are the maximum recommended when the unit is used in an average service application.
Maintenance Level 1 Level 2 Level 3 Level 4 T asks Recom- T ask Required T ask Required T ask T ask mended Comp . to be done Comp . to be done Comp . Required Comp. to be done (Date- 3 months/ (Date- Semi- (Date- to be done (Date- monthly Initials) Break-in Initials) annually Initials) Annually Initials) 10 Hrs.
Maintenance Level 1 Level 2 Level 3 Level 4 T asks Recom- T ask Required T ask Required T ask T ask mended Comp . to be done Comp . to be done Comp . Required Comp. to be done (Date- 3 months/ (Date- Semi- (Date- to be done (Date- monthly In itials) Break-in Initials) annually Initials) Annually Initials) 10 Hrs.
TROU BLESHOO TI NG GU IDE P ROBLEM CAUSE C OR RECTION Engine won’t crank. 1. 15 amp fuse blown. 1. Replace fuse. 2. Loose or corroded or defectiv e 2. Tighten, clean or replace batter y cables. batter y cables as necessary . 3. Defectiv e star ter contactor .
Standby Generator Sets Notes.
Standby Generator Sets Notes.
.
1 0F7135 1 BREA KER TR AY BA CK/BOTTOM 2 0F7022 1 SUPP ORT CO NTROL P ANEL S IDE RH 3 0F7021 1 SUPP ORT CO NTROL P ANEL S IDE LH 4 0F7260 1 COVE R CIRC UIT BREA KER 2P 0F7136 1 COV ER CIRC UIT BRE AKE.
.
1 098675 1 ASSY ROTO R 20 K W 2 0A5336A 1 HOUSING BL OWER 3 0A16 59 1 SCREE N AIR O UTLET 4 020746 4 SCRE W PPHM M5 -0 .8 X 8 ZINC 5 049226 4 WAS HER LO CK M5 6 051713 4 WAS HER FL AT M 5 7 022129 4 W.
.
1 0F1 823 A 1 ENCL HSB CONTROL PANEL 2 0F3 078 1 COVE R CO NTRO L P ANEL 3 0 F2606 1 HI NGE C ONTI NUOUS H-PN L 4 036261 6 RIVET PO P .125 X .275 SS 5 043181 4 SCREW PH M M 3 -0.5 X 10MM 6 05277 7 7 WASHE R FL AT M3 7 0F4 245F 1 ASS Y PCB CPL CT RLR 3600 RPM 8 0F 126 2 4 HO LDE R FU SE W I C K M A NN 178 .
.
1 0F34 08B 1 BAT TERY T RAY C 1 CPL 2 0F3 4 11 1 STRAP BA TT E RY RET A INM E NT 3 0 255 07 RE F WASHE R SHAKEP ROOF EXT 7/16 STL 4 0 52647 REF S CREW S HC M 10-1.
.
1 0F715 5 1 MOUN TING BA SE 1.5L C1 CPL 2 0274 82 2 WASHE R SH AKEPROO F EX T 5/1 6 STL 3 0709 36 2 DAMPE NER VI BRATIO N 4 07093 6C 2 V IB. I S O . 7 0-75 DU RO 5 0392 5 3 8 S CREW HH C M 8-1. 25 X 20 G8.8 6 0221 45 12 WASHER FLAT 5/16 ZINC 7 022129 12 WASHER LOCK M8-5/1 6 8 045771 4 NUT HE X M8-1.
.
1 0F7 211 1 SUP PORT R ADIATO R LH S IDE 2 0F7 2 09 1 VENTU RI 15" DI A FA N 3 0F7 210 1 SUP PORT R ADIATO R RH SIDE 4 0E9 837A 1 RADIA TOR 2 .5L CPL 5 0E 1936 1 FAN COOL ING 15" 6 02212 9 1 WA SHER LO CK M 8-5/16 7 0F7 166 1 RA DIATOR HOSE LW R 1.
.
1 0 98290 1 ASM MOTOR ST EPPER 2 098 941 A 1 HOU SING GO VERN OR CONN ECT OR 3 098958A 1 CONNECTOR INTE RFACE ASSEMBL Y 4 098942A 1 COVER CONNECTOR HO USING 5 0 98225 2 SCREW FHM #2 X 5/8 SELF TAP 6 0 43146 3 SCREW HHC M6-1.
.
1 0A4531 REF E NGINE-1.5L 2 022473 2 WASH ER F LA T 1/4 ZINC 3 * 055934 C 1 CLA MP VIN YL .5 X .406 Z 4 0A45 310 258 RE F. GASKET -EX HAUS T MA NIFOL D 5 0 A4355 1 MANIFOLD-EXHAUST 6 0E2632 1 HEAT SHI ELD EXH 1.5L 7 022097 4 WASH ER LOCK M6-1/4 8 02250 7 2 SCRE W HH C 1/4- 2 0 X 1/ 2 G5 9 052212 4 SCR EW HHC M10-1.
.
.
.
1 026812 2 ELBOW 90 D 3 /4 N PT 2 075580 1 FLANGE FUE L IN L E T 3 0F6 3 64 A 1 FUEL RGLT R 1.5L REW O RK 4 0392 53 4 S CREW HH C M8-1. 25 X 20 G8.8 5 0221 45 2 WAS HER FL AT 5/16 ZI NC 6 0221 29 6 WAS HER LO CK M8-5/ 16 7 045771 2 NUT HEX M8-1.
.
1 0F 700 3 (XX) 1 ROOF C 1 CP L 2 0F 7004 ( XX) 1 CO RNER POST L H SI DE C1 CPL 3 0F 7008 ( XX) 1 DO OR RE AR C 1 CPL 4 0F 7005 ( XX) 1 CO RNER POST RH SI DE C 1 CPL 5 0F 7007 ( XX) 2 DO OR L H & R H SIDE C1 CP L 6 0F 7006 ( XX) 1 DU CT F RONT DI SCHA RGE C 1 CPL 7 0 C2634 A 1 ASS EMBLY COVER ACCES S 8 091297 0091 1 ASSY WIRE 14AW G 13.
.
1 0F7366 1 MUFFLER C 1 2 0F7647 1 MUFFLER S ADDLE 3 0F809 5 1 PIPE E XHAUST OUTLET 4 0F7538 1 PIPE EXH INLET MUFLR SI DE 1.5L 5 0E3257 4 SCREW HWHTF M 6-1.0 X 16 6 0F7644 2 MUFFLER S TRAP 7 0C 61 1 9 1 BOLT U 5/16- 18 X 2-1 /4 8 0364 3 4 3 BO LT U 5/16-1 8 X 2.
.
.
.
.
.
.
Standby Generator Sets W arranty Printed in U.S.A. GENERA C PO WER SYSTEMS ST ANDARD LIMITED W ARRANTY FOR HOME ST ANDBY/LIGHT COMMERCIAL PRODUCT 45kW AND BELO W For a period of two (2) y ears from the date of sale, or start-up by A uthorized/Cer tified Generac P ower Systems Dealer , or branch thereof , Generac P ow er Systems, Inc.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Generac Power Systems 005210-0 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Generac Power Systems 005210-0 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Generac Power Systems 005210-0 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Generac Power Systems 005210-0 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Generac Power Systems 005210-0, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Generac Power Systems 005210-0.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Generac Power Systems 005210-0. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Generac Power Systems 005210-0 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.