Reference all appropriate documentation. This manual should remain with the unit. n NOT INTENDED FOR USE IN CRITICAL LIFE SUPPORT APPLICA TIONS. n ONL Y QUALIFIED ELECTRICIANS OR CONTRACT ORS SHOULD A TTEMPT INST ALLA TION. n DEADL Y EXHAUST FUMES! OUTDOOR INST ALLA TION ONL Y! LISTED C US T o lo ca te in Spanish, go to http:// www.
ii W ARNING! California Proposition 65 Engine exhaust and some of its constituents are known to the state of California to cause cancer , birth defects, and other reproductive harm.
T able of Content s iii Section 1 — Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1.1 — General Safety . . . . . . . . . . . . . . .
iv This p age intentionally lef t blank..
Automatic S tandby Gene rator Owner ’s Manual 1 Section 1 Safety INTRODUCTION: Thank you for purchasing this compact, high performance, air-cooled , engine-driven stationary automatic standby generator set.
2 Automati c S tandby Genera tor Owner ’s Manual 1.1 — General Safety Study these safety rules carefully before operating or servicing this equipment. Become familiar with this Owner’s Manual and w ith the unit. The generator can operate safely , efficiently and reliably only if it is properly insta lled, operated and maintained.
Automatic S tandby Gene rator Owner ’s Manual 3 1.3 — Exhaust Hazards • Generator engine exhaust contains DEADL Y carbon monoxide, an odorless, colorless, poisonous gas.
4 Automati c S tandby Genera tor Owner ’s Manual If this generator is used to po wer electrical load ci rcuits normally po wered by a utility power sou rce, it is required by code to install a transfer switch.
Automatic St andby Genera tor Owner ’s Manual 5 Section 2 General Information 2.1 — The Generator Figure 2-1: GA-420 Engine 7 kW Unit 2.2 — Protection Systems The generator may have to run for long periods of time with no operator present to monitor the engine/generator conditions.
6 Automatic St a ndby Generator Owner ’s Manual 2.3 — Emission Information The U.S. Environmental Protection Agency (E P A) requires that this generator comply wi th exhaust emission standards. This genera tor is certified to meet the applicable EP A emission levels , and is certified for use as a stationary engine for standby power generation.
Automatic St andby Genera tor Owner ’s Manual 7 2.4 — S pecifications 2.4.1 — Generator 2.4.2 — Engine The specification sheet for your generator was included in the documentation provided with the unit at the time of purchase. Fo r additional copies, consult your local Authorized Servic e Dealer for your s pecific generator model.
8 Automatic St a ndby Generator Owner ’s Manual Gaseous fuels such as natu ral gas and liquid prop ane gas are highly explosive. Even the slightest sp ark can ignit e such fuels and c ause an explo sion. No leak age of fuel is p ermitted. Natural ga s, which is lighter than air , tends to collect in high areas.
Section 3 Operation Automatic S tandby Gene rator Owner ’s Manual 9 3.1 — Controller Lid Operation • Lift lid from bottom to open. Lid will secure in place when opened.
10 Automati c S tandby Genera tor Owner ’s Manual 3.2 — Circuit Breaker The Main Line Circuit Breaker (MLCB) and control panel are located under the side panel cover . Open the side cover door to acce ss both the control panel and circuit breaker .
Automatic S tandby Gene rator Owner ’s Manual 11 3.3.1— Using the Auto/Off/Manual Buttons NOTE: Damage caused by mis-wiring of th e interconnect wires is not warrantable. NOTE: Loss of utility power will cause either the AUTO or OFF or MANUAL button to flash.
12 Automati c S tandby Genera tor Owner ’s Manual 3.4.1— Clearing an Alarm/W arning Cond ition T o clear an alarm or warning condition from the Control Panel, press the OFF button. Press OFF button again. The flashing or so lid indicator LED will turn off.
Automatic S tandby Gene rator Owner ’s Manual 13 3.5.1.3 — Load T ransfer The transfer of load when the generator is running is dependent upon the operating mode: 3.
14 Automati c S tandby Genera tor Owner ’s Manual 3.7.1— T r ansfer to Generator Power Source 1. Press the Control Panel OFF button. 2. Set the Main Circuit Breaker (Generator Disconnect) to its OFF (OPEN) position.
Automatic S tandby Gene rator Owner ’s Manual 15 3.8.1— Main Circuit Breaker (Generator Disconnect) This is a 2-pole breaker rated acco rding to relevant specifications. 3.9 — Battery Charger NOTE: The battery charger is integrated into the control panel.
16 Automati c S tandby Genera tor Owner ’s Manual This p age intentionally lef t blank..
Automatic S tandby Gene rator Owner ’s Manual 17 Section 4 Maintenance NOTE: Proper maintenance and proper and safe operation is crucial to the life of the ge nerator . Genuine Generac par ts MUST be u sed to ensure warranty coverage. NOTE: All service to this generator must be performed by a qualif ied service p erson only .
18 Automati c S tandby Genera tor Owner ’s Manual 4.2 — Service Schedule A TTENTION: All service work must be performed by a qualified service person only .
Automatic S tandby Gene rator Owner ’s Manual 19 3. V alve Adjustment (recommended after the first 20 hours of operation and then after every 3 00 hours of operation) Dates Performed: 4.3 — Checking Engine Oil Level When power outages necessitate running the generator for extended per iods, the oil level should be checked daily .
20 Automati c S tandby Genera tor Owner ’s Manual Figure 4-2: Recommended Oi l Based on T emperature • SAE 30 above 32 ºF (0 ºC) • 10W-30 between 40 ºF and -10 ºF (4 ºC and -23 ºC) • Synthetic 5W-30 for all temperature ranges* NOTE: *Synthetic oil should only be used after 100 hours of operation.
Automatic S tandby Gene rator Owner ’s Manual 21 Figure 4-3: Oil Drain Location 4.4 — Changing the Engine Air Cleaner 1. With the generator shut down, remove the top lid. 2. Disengage the wire clip and remove the air cleaner access cover . See Figure 4-4.
22 Automati c S tandby Genera tor Owner ’s Manual 4. Clean the plug by scraping or washing with a wire brus h and commercial solvent. Do not blast the plug to clean. 5. Check the spark plug gap using a wire feeler gauge. See Figure 4-5. Adjust t he gap by carefully bending the ground electrode to: •7 kW units - 0.
Automatic S tandby Gene rator Owner ’s Manual 23 9. Install the rubber plug into the fan screen. 10. Install the spark plug and attach the spark plug wire. 1 1. Install the back panel. Ensure that the alternator intake bel low is captured by the frame on back panel securely with out an y kinks.
24 Automati c S tandby Genera tor Owner ’s Manual Lead-acid batteries pres ent a risk of fire because they generate h ydrogen gas. Strictly observe the following pre- cautions: • DO NOT smoke when near the battery . • DO NOT cause flame or spark in the battery area.
Automatic S tandby Gene rator Owner ’s Manual 25 Figure 4-8: Battery Location and T erminals 4. Check the battery fluid level of unsealed batteries, and if neces sary , fill with distilled water only . DO NOT use tap water . Also, have the Dealer or a qualified Service T echnici an check the state of charge and condition.
26 Automati c S tandby Genera tor Owner ’s Manual 4.10.2 — Return to Service T o return the unit to service after storage: 1. V erify that utility power is turned off. 2. Check the tag on the engine for oil viscosity and classi ficat ion. If necessary , drain and refill with proper oil.
Automatic S tandby Gene rator Owner ’s Manual 27 Section 5 T roubleshooting Problem Cause Correction Engine will not crank. 1. Fuse blown. 2. Loose, corroded or defective battery cables. 3. Defective starter contact. 4. Defective starte r motor . 5.
28 Automatic S tandby Generator Owner ’s Manual This p age intentionally lef t blank..
Automatic S tandby Gene rator Owner ’s Manual 29 Section 6 Quick Reference Guide Problem Things to Check Ac tive Alarm Solution Unit running in AUTO but no power in house . Check MLCB NONE Check MLCB. Contact servi cing dealer if MLCB is in the ON position.
30 Automatic S tandby Generator Owner ’s Manual This p age intentionally lef t blank..
.
Part No. 0K6020 Rev . A 07/29/2014 Printed in USA © Generac Power Systems, Inc. All rights reserved S pecificati ons are subje c t to change without notice. No reproduction allow ed in any form without prior written consent from Ge ne ra c Power Systems, Inc.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Generac 6519 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Generac 6519 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Generac 6519 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Generac 6519 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Generac 6519, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Generac 6519.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Generac 6519. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Generac 6519 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.