Manuale d’uso / di manutenzione del prodotto 004721-0, 004722-0, 004723-0, 004724-0, 004725-0, 004725-1, 004725-2, 004725-3, 004726-0 del fabbricante Generac
Vai alla pagina of 52
Owner’ s Man ual ONL Y QUALIFIED ELECTRICIANS OR CONTRACTORS SHOULD A TTEMPT INST ALLA TION!! DEADL Y EXHAUST FUMES. OUTDOOR INST ALLA TION ONL Y! This manual should remain with the unit.
Generac ® Pow er Systems, Inc. I NTRODUCTION Thank you for purchasing this model of the standby generator set product line by Generac P ower Systems. Every effort was expended to make sure that the information and instructions in this manual are both accurate and current at the time the manual was writ- ten.
T able of Contents Guardian Liquid-cooled 1 5 kW , 20 kW and 2 5 kW Generators Generac ® Pow er Systems, Inc. 1 INTRODUCTION .................................. IFC SAFETY RULES ...................................... 2 Section 1 — GENERAL INFORMA TION .
2 Generac ® Pow er Systems, Inc. Study these SAFETY RULES carefully before installing, operating or servicing this equipment. Become familiar with this Owner’s Manual and with the unit. The genera- tor can operate safely , efficiently and reliably only if it is properly installed, operated and maintained.
Generac ® Pow er Systems, Inc. 3 • Inspect the generator regularly , and promptly repair or replace all worn, damaged or defective parts using only factory-approved parts. • Before performing any maintenance on the generator , disconnect its battery cables to prevent accidental start -up.
4 Generac ® Pow er Systems, Inc. 1.1 GEN ER A T OR This equipment is a liquid- cooled, engine - driven gen- erator set. The generator is designed to supply elec- trical power that operates critical electrical loads during utility power failure.
Generac ® Pow er Systems, Inc. 5 Recommended fuels should have a Btu content of at least 1,000 Btus per cubic foot for natural gas and at least 2,520 Btus per cubic foot for LP gas.
6 Generac ® Pow er Systems, Inc. Figure 1.6 - Low Coolant Level Sensor 1.7 .4 O VERSPEED SH UTDOWN The Pre-pack circuit board on liquid cooled units receives AC frequency (rpm) signals directly from the stator AC power windings, via sensing leads S15 and S16.
1.1 0 SP ECIF ICA TIONS 1.1 0.1 GEN ERA T OR SP E CI F ICA TIONS 1.1 0.2 ENGI NE SP ECIF ICA TIONS Make ..............................................................................Mitsubishi Displacement .............................................
8 Generac ® Pow er Systems, Inc. NOTE: P ort 1 is for NG only and P ort 2 is for LP vapor only . No provision for simultaneous fuels has been made. Serious injury or damage may occur if not con- figured pr operly . Please consult an authorized Generac Service Dealer with any questions.
Generac ® Pow er Systems, Inc. 9 NOTE: F or more information about the installation of a standby system, order Engine - Generator Standby Electric P ower Systems Installer’s Guide and Reference Manual (part #046622) from a Generac Authorized Service Dealer .
10 Generac ® Pow er Systems, Inc. NOTE: Generac recommends the use of a Generac P ower Systems “GTS” type transfer switch in conjunc- tion with this generator . 2.5 EM ERGENCY CI RCU IT IS OL A TION M E THOD This prevents overloading the generator by keeping electrical loads below the wattage/amperage capacity of the generator .
Generac ® Pow er Systems, Inc. 11 2.1 0 B A T TER Y I NST ALL A TION Standby generators installed with automatic transfer switches will crank and start automati- cally when NORMAL (UTILITY) source voltage is removed or is below an acceptable pr eset level.
12 Generac ® Pow er Systems, Inc. 2.1 1.2 TR ANSFER SWIT CH If this generator is used to supply power to any elec- trical system normally powered by an electric utility , the National Electrical Code requires that a transfer switch be installed. The transfer switch prevents elec- trical backfeed between two different electrical sys- tems.
Generac ® Pow er Systems, Inc. 13 3.2.1 HO URME T E R Indicates time the engine -generator has operated, in hours and tenths of hours. Use the hourmeter along with the periodic maintenance schedule for the gen- erator set.
14 Generac ® Pow er Systems, Inc. If the AUTO/OFF/MANUAL switch is switched too soon, the engine may start. If engine does start, it will shut down automatically in about two (2) minutes. • Set the generator main circuit breaker to its ON or CLOSED position.
Generac ® Pow er Systems, Inc. 15 4.2 C OOLI NG SY STEM Air intake and outlet openings in the generator com- partment must be open and unobstructed for contin- ued proper operation. This includes such obstruc- tions as high grass, weeds, brush, leaves and snow .
16 Generac ® Pow er Systems, Inc. 4.5.4 I NSPECT C OOLI NG SY S TEM • Inspect engine cooling system at least once each month. • Check hoses for damage, deterioration, leaks, etc. Correct any discrepancies found. • Check hose clamps for tightness.
Generac ® Pow er Systems, Inc. 17 Figure 4.3 – Engine Air Cleaner See the “Scheduled Maintenance,” Section 4.7, for air cleaner maintenance. 4.5.1 2 SP AR K PL UGS Reset the spark plug gap or replace the spark plugs as necessary . See Section 4.
18 Generac ® Pow er Systems, Inc. 4.6.3 BA TTER Y MAI NTENANCE The battery should be inspected per the “Scheduled Maintenance,” Section 4.7. The following procedure should be followed for inspection: 1. Inspect the battery posts and cables for tightness and corrosion.
Generac ® Pow er Systems, Inc. 19 Section 4 — Maintenance Guardian Liquid-cooled 1 5 kW , 20 kW and 2 5 kW Generators 4.7 S CH EDU LED MAI NTENANCE The following is a recommended maintenance schedule for Generac Guardian small standby and residential gen- erator sets.
20 Generac ® Pow er Systems, Inc. Section 4 — Maintenance Guardian Liquid-cooled 1 5 kW , 20 kW and 2 5 kW Generators Maintenance Level 1 Level 2 Level 3 Level 4 T asks Recom- T ask Required T ask Required T ask T ask mended Comp . to be done Comp .
Generac ® Pow er Systems, Inc. 21 Section 4 — Maintenance Guardian Liquid-cooled 1 5 kW , 20 kW and 2 5 kW Generators Maintenance Level 1 Level 2 Level 3 Level 4 T asks Recom- T ask Required T ask Required T ask T ask mended Comp. to be done Comp .
22 Generac ® Pow er Systems, Inc. Section 5 — T roubleshooting Guardian Liquid-cooled 1 5 kW , 20 kW and 2 5 kW Generators 5.1 TROU B LE SHOO TI NG POI NTS P ROBLEM CAUSE CORR E CTION Engine won’t crank. 1. 15 amp fuse b lown. 1. Replace fuse. 2.
Generac ® Pow er Systems, Inc. 23 Section 6 — Notes Guardian Liquid-cooled 1 5 kW , 20 kW and 2 5 kW Generators.
24 Generac ® Pow er Systems, Inc. Section 6 — Notes Guardian Liquid-cooled 1 5 kW , 20 kW and 2 5 kW Generators.
Generac ® Pow er Systems, Inc. 25 Section 7 - Installation Diagram Guardian Liquid-cooled 1 5 kW , 20 kW and 2 5 kW Generators Drawing No. 0E1 53 3.
NB S ET EXER C I S E S WIT CH TERMINAL S TRIP 7 P OS. V O LTA G E RE GU LAT OR VR T S3 - - S W 2 - FL - SU PRE SS I O N A SS EMBL Y NE U TRAL BL OCK FA U LT LI G H T H OU R METE R F US E 1 5 AMP S FIE.
Generac ® Pow er Systems, Inc. 27 Section 8 - Electrical Data Guardian Liquid-cooled 1 5 kW , 20 kW and 2 5 kW Generators Wiring Diagram — 1.5L Engine — Drawing No.
28 Generac ® Pow er Systems, Inc. Section 8 - Electrical Data Guardian Liquid-cooled 1 5 kW , 20 kW and 2 5 kW Generators Wiring Diagram — 1.5L Guardian — Drawing No.
Generac ® Pow er Systems, Inc. 29 Section 8 - Electrical Data Guardian Liquid-cooled 1 5 kW , 20 kW and 2 5 kW Generators Electrical Schematic — 1.5L — Drawing No.
ITEM P ART NO . QTY . DESCRIPTION 1 098290 1 ASM MO T OR STEPPER 2 098941A 1 HOUSING GO VERNOR CONNECT OR 3 098958A REF CONNECT OR INTERF ACE ASSEMBL Y 4 098942A 1 CO VER CONNECT OR HOUSING 5 098225 2 SCREW FHM #2 X 5/8 SELF T AP 6 043146 3 SCREW HHC M6-1.
ITEM P ART NO . QTY . DESCRIPTION 1 0D8656 1 BASE MOUNTING 1.5L STNRD & A CSTC 2 027482 2 W ASHER SHAKEPR OOF EXT 5/16 STL 3 070936 2 D AMPENER VIBRA TION 4 070936C 2 VIB. ISO. 70-75 DURO 5 039253 8 SCREW HHC M8-1.25 X 20 G8.8 6 022145 12 W ASHER FLA T 5/16 ZINC 7 022129 16 W ASHER LOCK M8-5/16 8 045771 4 NUT HEX M8-1.
32 Generac ® Pow er Systems, Inc. 17 G R OU ND WIRE. F A S TENER T O S E CU RE NO TE: W ELD S T U D U NDER R OO F E L F O R A CC E SS CO VER C ABLE NU T S ITEM #2 6 .
ITEM P ART NO . QTY . DESCRIPTION 1 0D8666 1 ROOF A CSTC&STND CMPR TMNT 1.5L 2 0D8664C 1 DUCT CENTER 1.5L 3 0D8657 1 SUPPOR T RADIA TOR 1.5L MITSU 4 0D8660 2 BRA CE SIDE 1.5L MITSU 5 0A7568 2 DOORWELDMENT 1.5EPS 6 0D8659 1 CORNER POST REAR RH SIDE 1.
34 Generac ® Pow er Systems, Inc. PANEL FOR ACCESS COVER CABLE W ELD S T U D U NDER R OO F P ANEL. S E CU RE A S S H O WN. T YPI C AL O F FR O NT D UC T & R OOF US E D OO R LAT C H NO TE: 24 43 3.
Generac ® Pow er Systems, Inc. 35 ITEM P ART NO . QTY . DESCRIPTION 1 0D8666 1 ROOF A CSTC & STND CMPR TMNT 1.5L 2 0D8664C 1 DUCT CENTER 1.5L 3 0D8657 1 SUPPOR T RADIA TOR 1.5L MITSU 4 0D8660 2 BRA CE SIDE 1.5L MITSU 5 0A7568 2 DOOR WELDMENT 1.5 EPS 6 0D8659 1 CORNER POST REAR RH SIDE 1.
36 Generac ® Pow er Systems, Inc. Section 9 - Exploded Views and P arts Guardian Liquid-cooled 1 5 kW , 20 kW and 2 5 kW Generators Control Panel — Drawing No.
Generac ® Pow er Systems, Inc. 37 ITEM P ART NO . QTY . DESCRIPTION 1 0D9322 1 P ANEL BACK & BO TT OM GU ARDIAN 2 0D9332 1 P ANEL LH SIDE GUARDIAN & SPRN 3 0D9325A 1 P ANEL FRONT CONTR OL GU ARDIAN W/ SILKSC 4 0D9330 1 P ANEL RH SIDE C-P ANEL SML BRK 5 0C1457 1 HOURMETER 6 064009 1 LIGHT 12VDC .
6 1 WATERPUMP HARDWARE 13 9 10 11 2 8 7 12 24 10 14 15 16 6 32 5 4 1 24 39 41 30 17 11 10 14 11 19 17 18 20 26 21 20 25 22 24 5 7 33 1 1 14 9 24 72 10 11 10 14 1 24 35 3 4 36 44 45 14 71 12 46 11 10 4.
ITEM P ART NO . QTY . DESCRIPTION 1 0A4531 1 ENGINE-1.5L 2 022473 2 W ASHER FLA T 1/4 ZINC 4 0A45310258 1 GASKET -EXHA UST MANIFOLD 5 0A4355 1 MANIFOLD-EXHA UST 6 0E2632 1 HEA T SHIELD EXH 1.5L 7 022097 8 W ASHER LOCK M6-1/4 8 022507 2 SCREW HHC 1/4-20 X 1/2 G5 9 052212 2 SCREW HHC M10-1.
14 11 17 28 ( BOTTOM ONLY ) "A " 28 22 9 30 3 2 29 10 2 21 1 3 2 3 35 18 14 12 33 17 34 4 TO WATER INLE T ( MIDWAY UP ENGINE BLOCK ) 14 TUBE (ON BLOCK) TO THERM OS TAT 3 1 10 23 26 8 20 WATE.
ITEM P ART NO . QTY . DESCRIPTION 1 0D8657 1 SUPPOR T RADIA TOR 1.5L MITSU 2 0A5734 1 RADIA TOR 1.5L 3 0A6237 1 VENTURI 1.5L MODINE 4 * 0A6238 1 GUARD F AN 1.5L MODINE 5 084918 1 HEA TER ENGINE 0500W 120V 6 050967 1 HOSE 5/8 ID RIA 250F 12" 7 048031C 4 CLAMP HOSE BAND 1/4 8 099502 4 CLAMP HOSE #24 B1.
42 Generac ® Pow er Systems, Inc. 2 9 33 32 31 1 8 2 0 1 0 1 9 L.P. VAP OR P O R T " OU T 2 " 41 4 0 11 14 9 " C" 12 14 1 6 17 8 4 3 1 5 " D" 4 5 27 42 2 3 2 7 6 4 0 21 .
Generac ® Pow er Systems, Inc. 43 ITEM P ART NO . QTY . DESCRIPTION 1 * --------- 1 WELDMENT MOUNTING BASE 2 075580 1 FLANGE FUEL INLET 3 0E1006 1 ASSY REGULA TOR 1.5L N.G.OR LPV 4 039253 2 SCREW HHC M8-1.25 X 20 G8.8 5 022145 2 W ASHER FLA T 5/16 ZINC 6 022129 6 W ASHER LOCK M8-5/16 7 045771 2 NUT HEX M8-1.
44 Generac ® Pow er Systems, Inc. 8 36 13 3 12 5 9 15 14 17 T o Blow e r H ousin g 3 2 2 3 24 35 1 21 28 7 22 33 10 29 16 30 18 2 6 19 20 3 1 2 1 4 T o En g ine C rankshaf t 26 Section 9 - Exploded Views and P arts Guardian Liquid-cooled 1 5 kW , 20 kW and 2 5 kW Generators Alternator — Drawing No.
Generac ® Pow er Systems, Inc. 45 ITEM P ART NO . QTY . DESCRIPTION 1 098671 1 ASSY RO T OR 10KW 098681 1 ASSY RO T OR 15KW 098675 1 ASSY RO T OR 20KW 098936 1 ASSY RO T OR 25KW 2 0A5336A 1 HOUSING BLOWER 3 0A1659 1 SCREEN AIR OUTLET 4 071912 4 SCREW PPHM M5-0.
ITEM P ART NO . QTY . DESCRIPTION 1 077483 1 BA TT 12VDC 75-AH 26 2 038804D 1 CABLE BA TT RED #4 X 20.00 3 038805B 1 CABLE BA TT BLK #4 X 23.00 4 0742600131 1 ASSY ,WIRE#16 RED 1.6 5 022131 1 W ASHER FLA T 3/8 ZINC 6 046526 1 W ASHER LOCK M10 7 052213 1 SCREW HHC M10-1.
Generac ® Pow er Systems, Inc. 47 ITEM P ART NO . QTY . DESCRIPTION 1 0A4355 1 MANIFOLD EXHA UST 1.5L 2 0E2844 1 NIPPLE T OE 1.5NPTX5.5 BLK IRON 3 036434 3 BOL T U 5/16-18 X 2.09 036449 3 SADDLE 2 INCH 4 0E0109 1 PIPE,EXHA UST 1.5L STNDRD&ACSTC 5 0C1318 1 FLEX PIPE EXHA UST 6 0D8657 1 SUPPOR T , RADIA TOR 1.
48 Generac ® Pow er Systems, Inc. CALI FOR N IA EM ISSION C ONTROL W AR R ANT Y S T A TEM ENT Y OU R W ARR ANT Y RIGHTS AND OB LIGA TIONS The California Air Resources Board (CARB) and Generac P ower Systems, Inc. (Generac) are pleased to explain the Emission Control System W arranty on your new engine.
Generac ® Pow er Systems, Inc. 49 EM IS SION CONTROL S Y STEM W AR R ANTY Emission Control System W arranty (ECS W arranty) for 1995 and later model year engines: (a) Applicability: This warranty shall apply to 1995 and later model year engines.
Part No. 0E1151 Revision J (06/28/04) Printed in U.S.A. Section 1 0 – W arranty Guardian Liquid-cooled 1 5 kW , 20 kW and 2 5 kW Generators GEN ERAC PO WER SY S TEMS S T AN D ARD "T WO YEAR&quo.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Generac 004721-0, 004722-0, 004723-0, 004724-0, 004725-0, 004725-1, 004725-2, 004725-3, 004726-0 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Generac 004721-0, 004722-0, 004723-0, 004724-0, 004725-0, 004725-1, 004725-2, 004725-3, 004726-0 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Generac 004721-0, 004722-0, 004723-0, 004724-0, 004725-0, 004725-1, 004725-2, 004725-3, 004726-0 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Generac 004721-0, 004722-0, 004723-0, 004724-0, 004725-0, 004725-1, 004725-2, 004725-3, 004726-0 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Generac 004721-0, 004722-0, 004723-0, 004724-0, 004725-0, 004725-1, 004725-2, 004725-3, 004726-0, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Generac 004721-0, 004722-0, 004723-0, 004724-0, 004725-0, 004725-1, 004725-2, 004725-3, 004726-0.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Generac 004721-0, 004722-0, 004723-0, 004724-0, 004725-0, 004725-1, 004725-2, 004725-3, 004726-0. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Generac 004721-0, 004722-0, 004723-0, 004724-0, 004725-0, 004725-1, 004725-2, 004725-3, 004726-0 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.