Manuale d’uso / di manutenzione del prodotto RAK147P1. RAL163P1 del fabbricante GE
Vai alla pagina of 20
www .GEAppliances.com 49-7406 11-00 JR Operating Instructions Auto Changeover . . . . . . . . . .10 Day/Time Setting Mode . . . . .6 Default Mode . . . . . . . . . . . . . . .4 Fan Control . . . . . . . . . . . . . . .10 Hold and Temporary Override . .
2 Using your thermostat. The digital programmable series of thermostats offers an economical remote control solution for single-stage heat/cool and multi-stage heat pump applications. System selections include heat, cool, off or auto mode, as well as fan on or fan auto selections.
T roubleshooting T ips Operating Instructions Safety Instructions Installation Instructions 3 www .GEAppliances.com KEY FUNCTION ▲ • Increases data (time, temperature, etc.). • Press with ▼ to enter span setting mode. ▼ • Decreases data (time, temperature, etc.
4 T emperature Scale Selection ■ The temperature scale can be selected by the C/F dip switch inside the unit. Please refer to Figure 3 in the Installation Instructions for identification of the correct switch. ■ If C/F switch is set at “F,” the temperature scale after reset is Fahrenheit.
T roubleshooting T ips Operating Instructions Safety Instructions Installation Instructions 5 www .GEAppliances.com T ime Format ■ Time is displayed in AM/PM format. ■ AM/PM format is <AM|PM>hh:mm where the leading zero of the hour will be suppressed.
6 Using your thermostat. Hold and T emporary Override ■ Hold is the permanent bypass of program temperature setpoints. Manual release is required to return to active program mode. ■ Press HOLD/RETURN in NORMAL mode for hold. The current setpoint temperature will be used.
7 www .GEAppliances.com Programming Mode The RAK163P1 and RAK147P1 are capable of programming in either 5+2 or 7 day formats. The table below is the default program for both the heating and cooling programs. If nothing is changed, these will be the times and temperatures that are active.
8 Using your thermostat. Press PROGRAM from the NORMAL mode. The program time- hour will be flashing and the MORNING time period will be active. Press ▲ or ▼ to adjust time. To change programming days press DA Y/TIME button. The order of the day programming is: ■ Weekday Program (i.
T roubleshooting T ips Operating Instructions Safety Instructions Installation Instructions 9 www .GEAppliances.com Press PROGRAM again. The next program time period will be displayed. The order of the time periods within one day are: 1. Morning 2. Day 3.
10 Fan Control ■ If FAN AUTO is selected, the fan will cycle On/Off with the system. If FAN ON is selected, the Fan will be on all the time. Using your thermostat. LCD Backlight ■ LCD backlight is activated when any key is pressed. Any subsequent key press or switch change will extend the period.
Open the cover on the thermostat and insert a small coin or flat-bladed screwdriver in the slot on the top of the thermostat and twist 1/4 turn. Grasp the base from the side and remove from the thermostat.
12 Installation Instructions MOUNTING AND WIRING (CONT .) Connect the wires from the existing system to the thermostat terminals according to the wiring diagrams in Table 1 and Table 2. Push any excess wire back into the wall and seal the hole with putty or a caulking material to prevent drafts from affecting the ambient temperature of the sensor.
DIP SWITCH SWITCH SELECTION FUNCTION 1 ON DC V oltage: 24 VDC OFF AC V oltage: 24 V AC 2O N ° C OFF °F 3 ON Keypad locked OFF Keypad unlocked 4 ON Backlight Override. Backlight does not operate if this switch is on. OFF Backlight is operating. Anytime a button is pressed, the backlight display will turn on.
THERMOSTAT COVERED RAK163P1, RAK147P1 Power Requirements 18–30 V AC or VDC electronic thermostat for 5-wire 1H/1C systems (RAK163P1) and 6-wire 2H/1C systems (RAK147P1) T emperature Measurement Rang.
15 T roubleshooting tips… www .GEAppliances.com Save time and money! Review the chart on this page first and you may not need to call for service. Problem Possible Causes What T o Do No display/faint display Supply voltage not correct. • Using a voltmeter, check the supply voltage to the thermostat.
16 Notes. T roubleshooting T ips Operating Instructions Safety Instructions Installation Instructions.
General Electric Company Warranty Registration Department P.O. Box 32150 Louisville, KY 40232-2150 Please place in envelope and mail to: ✁ Cut here 17 Consumer Product Ownership Registration Important Mail Today! General Electric Company Louisville, Kentucky www.
18 T roubleshooting T ips Operating Instructions Safety Instructions Installation Instructions Notes..
19 Notes. T roubleshooting T ips Operating Instructions Safety Instructions Installation Instructions.
20 Thermostat W arranty . For The Period Of: GE Will Replace: One Y ear Full Replacement of the thermostat which fails due to a defect in materials or workmanship. From the date of the original purchase ■ Service trips to your location. ■ Improper installation.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il GE RAK147P1. RAL163P1 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del GE RAK147P1. RAL163P1 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso GE RAK147P1. RAL163P1 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul GE RAK147P1. RAL163P1 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il GE RAK147P1. RAL163P1, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del GE RAK147P1. RAL163P1.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il GE RAK147P1. RAL163P1. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo GE RAK147P1. RAL163P1 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.