PROCESSING FREEZER / CHILLER / REFRIGERATION SYSTEM PHONE: 262.
Delivery ..................................... 1 Unpacking ................................... 1 Safety Procedures and Precautions ................ 2 Installation Site Installation ............................. 3 Clearance Requirements ...............
Q U I C K C H I L L E R • M N - 2 9 6 4 7 ( R E V . 0 ) • I N S T A L L A T I O N / O P E R A T I O N / S E R V I C E M A N U A L • 1. deLiVery This Alto-Shaam appliance has been thoroughly tested and inspected to insure only the highest quality unit is provided.
Q U I C K C H I L L E R • M N - 2 9 6 4 7 ( R E V . 0 ) • I N S T A L L A T I O N / O P E R A T I O N / S E R V I C E M A N U A L • 2. note For equipment delivered for use in any location regulated by the following directive: DO NOT DISPOSE OF ELECTRICAL OR ELECTRONIC EQUIPMENT WITH OTHER MUNICIPAL WASTE.
Q U I C K C H I L L E R • M N - 2 9 6 4 7 ( R E V . 0 ) • I N S T A L L A T I O N / O P E R A T I O N / S E R V I C E M A N U A L • 3. CLEARANCE REQUIREMENTS 18" (457 mm ) m i n i m u m c l e a r a n c e f r o m h e a t p r o d u c i n g e q u i p m e n t .
Q U I C K C H I L L E R • M N - 2 9 6 4 7 ( R E V . 0 ) • I N S T A L L A T I O N / O P E R A T I O N / S E R V I C E M A N U A L • 4. INSTALLATION REQUIREMENTS The model QC2-3 is a counter mounted unit and must use legs that allow for a 4" (102mm) clearance between the cabinet and the counter.
Q U I C K C H I L L E R • M N - 2 9 6 4 7 ( R E V . 0 ) • I N S T A L L A T I O N / O P E R A T I O N / S E R V I C E M A N U A L • 5. SITE INSTALLATION INSTALLATION QC2-100 Bottom View WATER DRAINAGE A 1" NPS drain is located under the QC2-100.
Q U I C K C H I L L E R • M N - 2 9 6 4 7 ( R E V . 0 ) • I N S T A L L A T I O N / O P E R A T I O N / S E R V I C E M A N U A L • 6. SUB TITLE TITLE 5" (127mm) Electrical Connection Cord .
Q U I C K C H I L L E R • M N - 2 9 6 4 7 ( R E V . 0 ) • I N S T A L L A T I O N / O P E R A T I O N / S E R V I C E M A N U A L • 7. SUB TITLE TITLE QC2-20 57 " (1448mm) 36 " (914mm).
Q U I C K C H I L L E R • M N - 2 9 6 4 7 ( R E V . 0 ) • I N S T A L L A T I O N / O P E R A T I O N / S E R V I C E M A N U A L • 8. SUB TITLE TITLE QC2-40 ALTO SHAAM 36" (914mm) 7" .
Q U I C K C H I L L E R • M N - 2 9 6 4 7 ( R E V . 0 ) • I N S T A L L A T I O N / O P E R A T I O N / S E R V I C E M A N U A L • 9. SUB TITLE TITLE QC2-100 INSTALLATIO N SITE INSTALLATION 41-.
Q U I C K C H I L L E R • M N - 2 9 6 4 7 ( R E V . 0 ) • I N S T A L L A T I O N / O P E R A T I O N / S E R V I C E M A N U A L • 10. SUB TITLE TITLE QC2-100R INSTALLATIO N SITE INSTALLATION 4.
Q U I C K C H I L L E R • M N - 2 9 6 4 7 ( R E V . 0 ) • I N S T A L L A T I O N / O P E R A T I O N / S E R V I C E M A N U A L • 11. SUB TITLE TITLE MODEL > QC2-3 QC2-20 QC2-40 QC2-100 QC2.
Q U I C K C H I L L E R • M N - 2 9 6 4 7 ( R E V . 0 ) • I N S T A L L A T I O N / O P E R A T I O N / S E R V I C E M A N U A L • 12. SUB TITLE TITLE ELECTRICAL INSTALLATION This appliance must be branch circuit protected with proper ampacities, in accordance with the wiring diagram.
Q U I C K C H I L L E R • M N - 2 9 6 4 7 ( R E V . 0 ) • I N S T A L L A T I O N / O P E R A T I O N / S E R V I C E M A N U A L • 13. TITLE OPERATION OPERATING INTRODUCTION The Alto-Shaam ® Q.
Q U I C K C H I L L E R • M N - 2 9 6 4 7 ( R E V . 0 ) • I N S T A L L A T I O N / O P E R A T I O N / S E R V I C E M A N U A L • 14. TITLE OPERATION CHILL PROCESSING CYCLES The Alto-Shaam Qui.
Q U I C K C H I L L E R • M N - 2 9 6 4 7 ( R E V . 0 ) • I N S T A L L A T I O N / O P E R A T I O N / S E R V I C E M A N U A L • 15. TITLE OPERATION ADDITIONAL INFORMATION ➤ Clean the Quickchiller and probes prior to use and make certain all processing modes are operating properly before chilling or freezing foods.
Q U I C K C H I L L E R • M N - 2 9 6 4 7 ( R E V . 0 ) • I N S T A L L A T I O N / O P E R A T I O N / S E R V I C E M A N U A L • 16. TITLE OPERATION … To rapidly decrease the temperature of foods by internal product probe temperature or time within a range of 24°F to 36°F (-4°C to 2°C).
Q U I C K C H I L L E R • M N - 2 9 6 4 7 ( R E V . 0 ) • I N S T A L L A T I O N / O P E R A T I O N / S E R V I C E M A N U A L • 17. SUB TITLE TITLE BASIC OPERATION OPERATION Starting from the o f f position, press the power key o n . The Alto-Shaam name will illuminate and the SELECTION SCREEN will appear on the display.
Q U I C K C H I L L E R • M N - 2 9 6 4 7 ( R E V . 0 ) • I N S T A L L A T I O N / O P E R A T I O N / S E R V I C E M A N U A L • 18. SUB TITLE TITLE caution ADEQUATE SPACING MUST BE ALLOWED BETWEEN PANS FOR PROPER AIR CIRCULATION FOR BOTH PROCESSING AND SUBSEQUENT HOLDING.
Q U I C K C H I L L E R • M N - 2 9 6 4 7 ( R E V . 0 ) • I N S T A L L A T I O N / O P E R A T I O N / S E R V I C E M A N U A L • 19. SUB TITLE TITLE MANUAL OPERATION Starting from the o f f position, press the power key o n . The Alto-Shaam name will illuminate and the SELECTION SCREEN will appear on the display.
Q U I C K C H I L L E R • M N - 2 9 6 4 7 ( R E V . 0 ) • I N S T A L L A T I O N / O P E R A T I O N / S E R V I C E M A N U A L • 20. ADVANCED OPERATION — PRESET PROGRAMMING OPERATION PRESET PROGRAM OPERATION 1. Starting from the o f f position, press the power key o n .
Q U I C K C H I L L E R • M N - 2 9 6 4 7 ( R E V . 0 ) • I N S T A L L A T I O N / O P E R A T I O N / S E R V I C E M A N U A L • 21. SUB TITLE TITLE chanGinG user settinGs Starting from the of f position, press the power key o n . The Alto-Shaam name will illuminate and the SELECTION SCREEN will appear on the display.
Q U I C K C H I L L E R • M N - 2 9 6 4 7 ( R E V . 0 ) • I N S T A L L A T I O N / O P E R A T I O N / S E R V I C E M A N U A L • 22. 8. HACCP DOWNLOAD (O nly on units with optional HACCP Datalogger ) Insert USB data stick into data port on front of the unit.
Q U I C K C H I L L E R • M N - 2 9 6 4 7 ( R E V . 0 ) • I N S T A L L A T I O N / O P E R A T I O N / S E R V I C E M A N U A L • 23. ADVANCED OPERATION – USER SETTINGS OPERATION 9. PROBE VERIFICATION With the probe verification selected, press the Start key to enter the probe verification mode.
Q U I C K C H I L L E R • M N - 2 9 6 4 7 ( R E V . 0 ) • I N S T A L L A T I O N / O P E R A T I O N / S E R V I C E M A N U A L • 24. TITLE OPERATION FOOD PROBE USE Unpacking Food Probes 1. Cut and remove the plastic ties keeping the probe cables coiled during shipment.
Q U I C K C H I L L E R • M N - 2 9 6 4 7 ( R E V . 0 ) • I N S T A L L A T I O N / O P E R A T I O N / S E R V I C E M A N U A L • 25. SUB TITLE TITLE OPERATION FOOD HANDLING GUIDELINES PRODUCT COVERING To maintain sanitation control when loading the Quickchiller, foods should be above 140°F (60°C) and should be tightly covered.
Q U I C K C H I L L E R • M N - 2 9 6 4 7 ( R E V . 0 ) • I N S T A L L A T I O N / O P E R A T I O N / S E R V I C E M A N U A L • 26. TITLE OPERATION PRODUCT CAPACITY PER PAN: Foods for chill or freeze processing should be portioned into shallow pans to a depth not to exceed 2-inches (51mm).
Q U I C K C H I L L E R • M N - 2 9 6 4 7 ( R E V . 0 ) • I N S T A L L A T I O N / O P E R A T I O N / S E R V I C E M A N U A L • 27. TITLE OPERATION THE FOLLOWING CHART OF PORTION SIZES AND SERVING CAPACITY PER PAN IS PROVIDED AS A GENERAL REFERENCE ONLY.
Q U I C K C H I L L E R • M N - 2 9 6 4 7 ( R E V . 0 ) • I N S T A L L A T I O N / O P E R A T I O N / S E R V I C E M A N U A L • 28. TITLE CARE AND CLEANING protecting stainLess steeL surfaces It is important to guard against corrosion in the care of stainless steel surfaces.
Q U I C K C H I L L E R • M N - 2 9 6 4 7 ( R E V . 0 ) • I N S T A L L A T I O N / O P E R A T I O N / S E R V I C E M A N U A L • 29. TITLE INTERIOR CLEANING Remove the optional roll-in cart (trolley) from cart equipped models. Open the Quickchiller door to warm the interior of the cabinet.
Q U I C K C H I L L E R • M N - 2 9 6 4 7 ( R E V . 0 ) • I N S T A L L A T I O N / O P E R A T I O N / S E R V I C E M A N U A L • 30. TITLE TROUBLESHOOTING CONTROL ERROR DISPLAYS control d i s.
PARTS INFORMATION QUICKCHILLER PARTS • M N - 2 9 6 4 7 ( R E V . 0 ) • I N S T A L L A T I O N / O P E R A T I O N / S E R V I C E M A N U A L • 31.
parts information QUICKCHILLER PARTS • M N - 2 9 6 4 7 ( R E V . 0 ) • I N S T A L L A T I O N / O P E R A T I O N / S E R V I C E M A N U A L • 32. 1 3 2 4 7 5 6 8 9 10 11 12 13 14 21 20 16 17 18 15 19 4 QC2-3 BOX VIEW Item Part Description Qty.
PARTS INFORMATION QUICKCHILLER PARTS • M N - 2 9 6 4 7 ( R E V . 0 ) • I N S T A L L A T I O N / O P E R A T I O N / S E R V I C E M A N U A L • 33.
parts information QUICKCHILLER PARTS • M N - 2 9 6 4 7 ( R E V . 0 ) • I N S T A L L A T I O N / O P E R A T I O N / S E R V I C E M A N U A L • 34.
PARTS INFORMATION QUICKCHILLER PARTS • M N - 2 9 6 4 7 ( R E V . 0 ) • I N S T A L L A T I O N / O P E R A T I O N / S E R V I C E M A N U A L • 35.
parts information QUICKCHILLER PARTS • M N - 2 9 6 4 7 ( R E V . 0 ) • I N S T A L L A T I O N / O P E R A T I O N / S E R V I C E M A N U A L • 36.
PARTS INFORMATION QUICKCHILLER PARTS • M N - 2 9 6 4 7 ( R E V . 0 ) • I N S T A L L A T I O N / O P E R A T I O N / S E R V I C E M A N U A L • 37. QC-20 BOX VIEW 14 9 12 11 9 10 7 8 4 3 5 1 2 6 15 16 17 18 18 19 13 20 21 20 Item Part Description Qty.
parts information QUICKCHILLER PARTS • M N - 2 9 6 4 7 ( R E V . 0 ) • I N S T A L L A T I O N / O P E R A T I O N / S E R V I C E M A N U A L • 38.
PARTS INFORMATION QUICKCHILLER PARTS • M N - 2 9 6 4 7 ( R E V . 0 ) • I N S T A L L A T I O N / O P E R A T I O N / S E R V I C E M A N U A L • 39.
parts information QUICKCHILLER PARTS • M N - 2 9 6 4 7 ( R E V . 0 ) • I N S T A L L A T I O N / O P E R A T I O N / S E R V I C E M A N U A L • 40. 3 2 Apply Weather Stripping to Front T op Edge of Panel 4 1 5 5 6 9 7 8 Item Part Description Qty.
PARTS INFORMATION QUICKCHILLER PARTS • M N - 2 9 6 4 7 ( R E V . 0 ) • I N S T A L L A T I O N / O P E R A T I O N / S E R V I C E M A N U A L • 41.
parts information QUICKCHILLER PARTS • M N - 2 9 6 4 7 ( R E V . 0 ) • I N S T A L L A T I O N / O P E R A T I O N / S E R V I C E M A N U A L • 42.
PARTS INFORMATION QUICKCHILLER PARTS • M N - 2 9 6 4 7 ( R E V . 0 ) • I N S T A L L A T I O N / O P E R A T I O N / S E R V I C E M A N U A L • 43. QC2-40 COIL 2 2 1 Suction Line 1 3 Hot Gas Defrost Line Discharge Line Item Part Description Qty.
parts information QUICKCHILLER PARTS • M N - 2 9 6 4 7 ( R E V . 0 ) • I N S T A L L A T I O N / O P E R A T I O N / S E R V I C E M A N U A L • 44.
PARTS INFORMATION QUICKCHILLER PARTS • M N - 2 9 6 4 7 ( R E V . 0 ) • I N S T A L L A T I O N / O P E R A T I O N / S E R V I C E M A N U A L • 45. QC2-40 DOOR (AFTER JUNE 1, 2012) 1 3 2 1 4 1 3 2 1 4 LEFT-HAND RIGHT-HAND Item Part Description Qty.
parts information QUICKCHILLER PARTS • M N - 2 9 6 4 7 ( R E V . 0 ) • I N S T A L L A T I O N / O P E R A T I O N / S E R V I C E M A N U A L • 46.
PARTS INFORMATION QUICKCHILLER PARTS • M N - 2 9 6 4 7 ( R E V . 0 ) • I N S T A L L A T I O N / O P E R A T I O N / S E R V I C E M A N U A L • 47. QC2-40 CONTROL PANEL - HINGED LEFT (PRIOR TO JUNE 1, 2012) 12 13 1 2 3 4 5 6 7 8 9 10 16 15 14 11 17 19 18 19 20 Item Part Description Qty.
parts information QUICKCHILLER PARTS • M N - 2 9 6 4 7 ( R E V . 0 ) • I N S T A L L A T I O N / O P E R A T I O N / S E R V I C E M A N U A L • 48. QC2-40 CONTROL PANEL - HINGED LEFT (AFTER JUNE 1, 2012) 6 5 1 2 3 15 14 7 10 11 8 16 9 12 13 4 17 Item Part Description Qty.
PARTS INFORMATION QUICKCHILLER PARTS • M N - 2 9 6 4 7 ( R E V . 0 ) • I N S T A L L A T I O N / O P E R A T I O N / S E R V I C E M A N U A L • 49. QC2-40 CONTROL PANEL - HINGED RIGHT (AFTER JUNE 1, 2012) 6 5 2 3 4 14 13 7 10 11 8 1 9 12 17 15 16 Item Part Description Qty.
parts information QUICKCHILLER PARTS • M N - 2 9 6 4 7 ( R E V . 0 ) • I N S T A L L A T I O N / O P E R A T I O N / S E R V I C E M A N U A L • 50.
PARTS INFORMATION QUICKCHILLER PARTS • M N - 2 9 6 4 7 ( R E V . 0 ) • I N S T A L L A T I O N / O P E R A T I O N / S E R V I C E M A N U A L • 51.
parts information QUICKCHILLER PARTS • M N - 2 9 6 4 7 ( R E V . 0 ) • I N S T A L L A T I O N / O P E R A T I O N / S E R V I C E M A N U A L • 52.
PARTS INFORMATION QUICKCHILLER PARTS • M N - 2 9 6 4 7 ( R E V . 0 ) • I N S T A L L A T I O N / O P E R A T I O N / S E R V I C E M A N U A L • 53.
parts information QUICKCHILLER PARTS • M N - 2 9 6 4 7 ( R E V . 0 ) • I N S T A L L A T I O N / O P E R A T I O N / S E R V I C E M A N U A L • 54.
PARTS INFORMATION QUICKCHILLER PARTS • M N - 2 9 6 4 7 ( R E V . 0 ) • I N S T A L L A T I O N / O P E R A T I O N / S E R V I C E M A N U A L • 55. QC2-100 INTERIOR, RIGHT-HAND VIEW 8 9 10 11 12 1 2 4 3 7 5 6 * not shown Item Part Description Qty.
parts information QUICKCHILLER PARTS • M N - 2 9 6 4 7 ( R E V . 0 ) • I N S T A L L A T I O N / O P E R A T I O N / S E R V I C E M A N U A L • 56. QC2-100 CONTROL PANEL, UNIT HINGED LEFT 8 12 16 18 17 19 10 9 14 20 5 13 11 4 3 7 1 6 2 15 Item Part Description Qty.
PARTS INFORMATION QUICKCHILLER PARTS • M N - 2 9 6 4 7 ( R E V . 0 ) • I N S T A L L A T I O N / O P E R A T I O N / S E R V I C E M A N U A L • 57. QC2-100 CONTROL PANEL, UNIT HINGED RIGHT 9 12 11 10 13 14 4 7 8 6 5 19 17 16 18 1 2 3 15 Item Part Description Qty.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
TRANSPORTATION DAMAGE and CLAIMS All Alto-Shaam equipment is sold F.O.B. shipping point, and when accepted by the carrier, such shipments become the property of the consignee. Should damage occur in shipment, it is a matter between the carrier and the consignee.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Alto-Shaam QC2-100 REMOTE è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Alto-Shaam QC2-100 REMOTE - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Alto-Shaam QC2-100 REMOTE imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Alto-Shaam QC2-100 REMOTE ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Alto-Shaam QC2-100 REMOTE, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Alto-Shaam QC2-100 REMOTE.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Alto-Shaam QC2-100 REMOTE. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Alto-Shaam QC2-100 REMOTE insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.