Manuale d’uso / di manutenzione del prodotto 000 gpd to 288 del fabbricante GE
Vai alla pagina of 45
E4H-CE AND E8-CE SERIES W A TER PURIFICA TION MACHINES 3 m 3 /hr to 45 m 3 /hr 18,000 gpd to 288,000 gpd Operation and Maintenance Manual.
.
INSTRUCTIONS FOR E4H-CE AND E8-CE W A TER PURIFICA TION OPERA TION AND MAINTENANCE MANUAL T ABLE OF CONTENTS Page 1.0 DESCRIPTION 1 1.1 Definitions 1 1.1.1 Permeate Rate 1 1.1.2 Concentrate Rate 1 1.1.3 Feed Rate 1 1.1.4 Reverse Osmosis 1 1.1.5 Membrane Elements 2 1.
Page 4.0 MACHINE OPERA TION AND MAINTENANCE 17 4.1 Daily Log Sheets 17 4.2 Pre-Filter Cartridge 17 4.3 Cleaning 17 4.4 Draining Machine for Shipment 19 4.5 Membrane Element Replacement 19 4.6 Membrane Element Removal 21 5.0 FIELD INST ALLED ACCESSORIES 22 5.
Page LIST OF FIGURES Figure T itle 1.1 Normal V ersus Cross Flow Filtration 1 1.2 Membrane Element W ith Interconnectors 2 1.3 Principles of Operation 3 LIST OF T ABLES Figure T itle 1.1 Flow Specifications for E-CE Reverse Osmosis Machines 7 1.2 Minimum/Maximum Boost Pressure 8 1.
1.0 DESCRIPTION E-CE Series Reverse Osmosis (RO) machines are durable pieces of equipment, which, with prop- er care, will last for many years. These instructions give operation and maintenance details vital to the sustained performance of the machine.
1.1.5 Membrane Elements Membrane elements are interleaved layers of semi-permeable membrane, spacer , and permeate carrier spiraled around a central permeate tube make up the mem- brane element. Figure 1.2 Membrane Element with Interconnectors 1.1.6 Clean-In-Place The abbreviation for Clean-In-Place is CIP .
C f = Feed Concentration C p = Permeate Concentration C c = Concentrate Concentration C avg = A verage Concentration in Machine 1.1.10 Salt (Ionic) Passage Ionic Salt Passage equals the percent of dissolved salts passed through the mem- brane element or 100% minus rejection.
4 Rejection = [(C avg ) - (C P )] x 100 (C avg ) = [(237.5 mg/L) + (8.3 mg/L)] x 100 (237.5) = 96.5% Passage = (C P ) x 100 (C f ) = (8.3 mg/L) x 100 (237.
1.2 Machine Nomenclature E-CE Series water purification machines are numbered in such a way as to indicate the permeate flow you can expect from the machine and other specifications: Example: RE, E8-CE-9, 400, 5, 66 - 75 1.
6 · Multi-stage centrifugal pump, SS construction (SS end castings and wetted parts, Noryl* internals) on the 3 to 3 to 34m 3 /hr and AS (all Stainless Steel components) on the 45m 3 /hr .
1.4 Specifications for E-CE Series Machines The machine flow specifications listed, T able 1.1 below , are based on 25 ° C (77 ° F) and 2000 ppm NaCl.
1.4.1 Feed W ater Specifications The feed water requirements listed in T able 1.1 must be met to ensure quality per- meate and extended membrane element life.
1.4.5 Reverse Osmosis Membrane Element Rejection E8-CE RO machines use Fiberglass Reinforced Plastic (FRP). E4H-CE RO machines use tape wrapped membrane elements.
2.0 INST ALLA TION The following installation guidelines will help you install your new E-CE RO machine. 2.1 Feed W ater Requirements The following feed water requirements must be met before installing your new E-CE RO machine to ensure quality permeate and extended membrane element life.
membrane element housings for removal and loading of membrane elements. If 1 14 cm (45-inches) are not available, the entire membrane element housing may need to be removed for membrane element replacement. 2.3 Plumbing The E4H-CE and E8-CE come with flanged connections installed on all isolation valves.
3.0 PREP ARA TION AND ST AR T -UP 3.1 Pretreatment for W ater Purification All systems will operate most efficiently on filtered water with a pH of less than 6.5 and a Silt Density Index (SDI) of 5 or below . If the machine is operated on higher pH water, other forms of pretreatment may be necessary .
STEPS 1. Recheck the function and integrity of your pretreatment equipment. Ensure that your water softener , activated carbon filters, and iron filters (where applicable) have been leaked checked, back washed, and thoroughly rinsed for service before starting up your RO unit.
It is also important to understand the relationship of these two valves, the pressure gauge, and your RO pump. The pump has a fixed amount of flow produced, and the valves are the control devices to distribute this fixed flow amount. The pres- sure gauge is an indicator of applied membrane element pressure a the flows set by the valves 8.
15. As the machine purges the air and fills with water , the pressure will gradually increase. W ater should flow through the permeate and concentrate piping, viewed on the individual flow meters. If you do not see flow , turn the machine OFF and return to Section 3.
3.3 Daily Start-Up Check the machine to insure isolation valves are in the proper positions for operation. T o turn the RO ON, press the RO button so it is in the ON position. If the alarm light is lit, push the “Alarm Reset” switch on the control enclosure and the alarm button on the OIT .
4.0 MACHINE OPERA TION AND MAINTENANCE The operation and maintenance of a E-CE RO Series machine is relatively simple, but requires regular data recording and routine preventative maintenance. It cannot be emphasized enough the importance of filling out the Daily Log Sheet (Section 7.
flow and/or rejection of salts, or an increased pressure drop across the machine will indi- cate when cleaning is required. GE Osmonics recommends cleaning at least every month to assure good membrane element performance and long membrane element life.
reestablish normal operation. Operate the machine as described in the flushing section for at least one hour . The deter gent is sufficiently flushed when the per- meate conductivity is restored to its normal previous level. When conductivity is back to normal, divert the permeate and concentrate back to service positions.
2. Cut the bag open as close as possible to the seal at the end of the bag, so that the bag may be reused if necessary . 3. Remove the membrane element from the bag and remove the foam protectors from each end of the membrane element. 4. Remove the parts from the parts container (if included) and inspect.
4.6 Membrane Element Removal As time progresses, the efficiency of the membrane element will be reduced. In general, the salt rejection does not change much until two or three years after installation, when operated on properly pretreated feed water and routine maintenance performed.
5.0 FIELD INST ALLED ACCESSORIES 5.1 Pretreatment Shutdown E-CE Series RO machines are equipped with Pretreatment Shutdown control capability . Pretreatment Shutdown is the ON/OFF control of the RO via a signal from a remote device. External Control can be used when Permeate Flush is not desired prior to RO shutdown (Permeate Flush, Section 5.
centration of the diluted feed stream, at the operating recovery , is that the water in the machine at shutdown will have total dissolved solids (TDS) concentrations approximate- ly equal to the machine feed TDS level.
4. T urn the AUTO/HAND Button on the Pur ge Button located on the OIT to the “AUTO” position. W ith multiple remote devices wired in series, as described above, an open contact from any of the configured devices will activate the Permeate Purge Cycle.
6.0 TROUBLESHOOTING This troubleshooting guide can assist you in identifying common operating problems you may experience with your machine. The operator can easily correct many of these problems, howev- er , for those that persist or are not understood you should contact the GE Osmonics Customer Support Center .
26 TROUBLESHOOTING SYMPTOM Low operating pressur e (continued) Low permeate flow rate POSSIBLE CAUSES Insufficient electrical power Pump not operating correctly Low operating pressure Dirty or fouled .
27 TROUBLESHOOTING SYMPTOM Low permeate flow rate (continued) Low concentrate flow rate, normal or higher than normal pressur e POSSIBLE CAUSES Operating on cold water less than 13 ° C (55 ° F) Memb.
SYMPTOM High operating pressur e W ater flowing when machine is turned OFF Declining rejection (high permeate conductivity) POSSIBLE CAUSES Recycle or concentrate valve plugged Inaccurate pressure gau.
29 TROUBLESHOOTING SYMPTOM Declining rejection (high permeate conductivity) (continued) Machine not operating POSSIBLE CAUSES O-ring seal broken or dam- aged Change in incoming water quality Inaccurat.
30 TROUBLESHOOTING SYMPTOM Machine not operating (continued) Electrical machine shut down POSSIBLE CAUSES Thermal overload in motor has tripped No power to machine Motor and/or pump not oper- ating pr.
TROUBLESHOOTING SYMPTOM Electrical machine shut down (continued) Conductivity drifts or changes after calibration Display is blank pH reading is off by mor e than 1pH unit POSSIBLE CAUSES Motor starter overloaded, heater tripped.
TROUBLESHOOTING 32 SYMPTOM Chemical pump will not feed chemical Chemical pump feed reverse of what you expect- ed POSSIBLE CAUSES Pumping may be affected by other software variables Relay set point no.
7.0 FORMS 7.1 RETURN GOODS AUTHORIZA TION (RGA) If you wish to return goods for repair , warranty evaluation and/or credit, please have your original sales order or invoice available when you call GE Osmonics. Call GE Osmonics at (800) 848 - 1750 and ask to speak with Customer Service.
34 E-SERIES ST AR T -UP DA T A SHEET Customer: Model Number: Serial Number: Date: T ested By Units (Circle One) Data Data Remarks Permeate Rate T otal Flow Rate Pre-Filter Pr essure Post-Filter Pressu.
35 7.3 Daily Log Sheet NAME OF COMP ANY NOTE : Please record all calibrations of instruments or other occurrences related to this system. This is a template. Make copies as needed. *Symbols: Q - Flow Rate; C - Conductivity Reference the T roubleshooting Guide in your Instruction Manual where trends or differences are noted .
8.0 W ARRANTY 8.1 W arranty T erms Subject to the terms and conditions set forth hereinafter , Seller (GE Osmonics, Inc. or any of its authorized subsidiaries) warrants to the original purchaser (here.
discretion, be the sole judge of whether a returned product or component is defective in material or workmanship. Required or replaced products or components shall be returned freight.
NO W ARRANTY OR OTHER LIABILITY OF SELLER TO BUYER UNDER THIS AGREEMENT OR OTHER WISE WILL IN ANY EVENT EXCEED THE COST OF REPLACEMENT OF THE APPLICABLE SELLER PRODUCT , P AR T , OR ACCESSO- R Y THA T IS SUBJECT TO ANY BREACH OF SELLER’S W ARRANTY .
.
Corporate Headquarters 5951 Clearwater Drive Minnetonka, MN 55343-8995 USA (952) 933-2277 Phone (952) 933-0141 Fax Euro/Africa Operations 230 rue Robert Schuman Z A des Uselles F-77350 Le MØe sur Sei.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il GE 000 gpd to 288 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del GE 000 gpd to 288 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso GE 000 gpd to 288 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul GE 000 gpd to 288 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il GE 000 gpd to 288, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del GE 000 gpd to 288.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il GE 000 gpd to 288. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo GE 000 gpd to 288 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.