Manuale d’uso / di manutenzione del prodotto P62-Series del fabbricante GarrettCom
Vai alla pagina of 37
ww w Gar rett C om com .. ww w Gar rett C om com .. ww w Gar rett C om com .. Corporate Headquarters GarrettCom, Inc. 213 Hammond Avenue Fremont, CA 94539 Phone: 510.
Magnum P62-Series Hardened Switches Installation and User Guide (08/03) i ww w Gar rett C om com .. Magnum P62-Series (P62F and managed mP62 m odels) Hardened Ethernet Switches Installation and Us.
Magnum P62-Series Hardened Switches Installation and User Guide (08/03) ii ww w Gar rett C om com .. Contacting GarrettCom, Inc Please use the mailing address, phone and fa x numbers and email address listed below: GarrettCom, Inc. 213 Hammond Ave. Fremont, CA 94539 Phone (510) 438-9071 Fax (510) 438-9072 Website: http://www.
Magnum P62-Series Hardened Switches Installation and User Guide (08/03) iii ww w Gar rett C om com .. MAGNUM ETHERNET CONNECTIVITY PRODUCTS "DESIGNED AND M ANUFACTURED IN THE USA" Overview GarrettCom, Inc. offers the Magnum line of Ethernet LAN connectivity products with industry-standard functionality.
Magnum P62-Series Hardened Switches Installation and User Guide (05/03) 1 ww w Gar rett C om com .. TABLE OF CONTENTS PAGE 1.0 SPECIFIC ATIONS..............................................................................................2 1.1 Technical Sp ecifications .
Magnum P62-Series Hardened Switches Installation and User Guide (08/03) 2 ww w Gar rett C om com .. Rev A 04/01 : This revision is the initial release of the P62F Hardened Switches user manual.
Magnum P62-Series Hardened Switches Installation and User Guide (08/03) 3 ww w Gar rett C om com .. Conformal coating (tropical humidity protection) optional, request quote Power Supply (Internal ) 24VDC and -48VDC Power Supply Power Input Voltage: 20 to 60 VDC (aut o-ranging), “-, GND, +” Power Consumpti on: 10 watts typi cal.
Magnum P62-Series Hardened Switches Installation and User Guide (08/03) 4 ww w Gar rett C om com .. MTBF (Bellcore method) Over 10 years MTBF. Email sales@GarrettCom.com for details Agency Approvals UL Listed (UL 60950), cUL, CB, CE Low Volt. Dir. & Electro-Magnetic Comp.
Magnum P62-Series Hardened Switches Installation and User Guide (08/03) 5 ww w Gar rett C om com .. 1.2 Ordering Information Magnum P62-Series, 10/100 Ethernet Switch Magnum P62F-AC-2MSC: P62F-AC Ethernet Switch with six 10/100 RJ-45 and two 100Mb FDX fiber multi-mode SC-type ports.
Magnum P62-Series Hardened Switches Installation and User Guide (08/03) 6 ww w Gar rett C om com .. Managed P62-Series (mP62) Hardened Sw itches Magnum mP62-AC-2MSC: mP62-AC Managed Switch with six10/100 RJ-45 and two 100Mb FDX fiber multi-mode SC-type ports.
Magnum P62-Series Hardened Switches Installation and User Guide (08/03) 7 ww w Gar rett C om com .. 2.0 INTRODUCTION 2.1 Inspecting the Package and Product Examine the shipping container for obvious damage prior to installing this product; notify the carrier of any damage that y ou believe occurred during shipment or delivery.
Magnum P62-Series Hardened Switches Installation and User Guide (08/03) 8 ww w Gar rett C om com .. 2.2 Product Description The Magnum P62-Series Ethernet “Outdoor ” Switches are designed to operate in extended temperature applications and are suitable for use in environments with inhospitable high / low temperatures.
Magnum P62-Series Hardened Switches Installation and User Guide (08/03) 9 ww w Gar rett C om com .. performance plug-and-play operation in a rugged package.
Magnum P62-Series Hardened Switches Installation and User Guide (08/03) 10 ww w Gar rett C om com .. The Magnum P62-5V models ar e available with an Extern al Power Source (Optional) for power input of universal AC power using the Magnum PSX-A unit.
Magnum P62-Series Hardened Switches Installation and User Guide (08/03) 11 ww w Gar rett C om com .. The serial (Console) port is provided on th e right front of the Managed mP62 Switch to use the Console Management Interface(CMI) to manage all functions of the s witch.
Magnum P62-Series Hardened Switches Installation and User Guide (08/03) 12 ww w Gar rett C om com .. format, a separate document normally accessed via the web-browser, ftp://ftp.
Magnum P62-Series Hardened Switches Installation and User Guide (08/03) 13 ww w Gar rett C om com .. 2.3 Fiber port, SC Conn ectors The Fast Ethernet fiber switched ports on the Magnum P62-Series operate at fixed 100Mb speed and full-duplex mode for the best performance.
Magnum P62-Series Hardened Switches Installation and User Guide (08/03) 14 ww w Gar rett C om com .. greatest. To minimize the possibility of dropping frames on congested ports, each Magnum P62- Serie.
Magnum P62-Series Hardened Switches Installation and User Guide (08/03) 15 ww w Gar rett C om com .. 2.5 Features and Benefits ! 100Mb switching services for hi gh performance Ethernet LANs Magnum P62-Series Switches provide Fast Ethernet switching on all ports.
Magnum P62-Series Hardened Switches Installation and User Guide (08/03) 16 ww w Gar rett C om com .. 2.6 Applications The P62-Series is designed specifically for harsh temperature environments and brings future-proof fiber and widely-used coppe r connectivity to out-of-the-way sites.
Magnum P62-Series Hardened Switches Installation and User Guide (08/03) 17 ww w Gar rett C om com .. Example 2. The Magnum P62F fits very well in hi gh temperature locations (control rooms) experiencing a need to scale its LAN quickly and cost effectively.
Magnum P62-Series Hardened Switches Installation and User Guide (08/03) 18 ww w Gar rett C om com .. Example 3. Magnum mP62 Fig .2.6.3 The Magnum Managed mP62 in a ring topology application In an un c.
Magnum P62-Series Hardened Switches Installation and User Guide (08/03) 19 ww w Gar rett C om com .. 3.0 INSTALLATION This chapter provides instructions fo r installing Magnum P62-Series units.
Magnum P62-Series Hardened Switches Installation and User Guide (08/03) 20 ww w Gar rett C om com .. 20.1cm) center-to-center. Four user-supplied sc rews, ¼” max diameter, attach the P62’S base plate to the vertical mounting surface. Th e PSX Power Source mounting is sim ilar.
Magnum P62-Series Hardened Switches Installation and User Guide (08/03) 21 ww w Gar rett Com com .. 3.2 Connecting Ethernet Med ia, and Special Strain -relief feature Note – see also “Cable Strai n Relief Feat ure, Section 3.
Magnum P62-Series Hardened Switches Installation and User Guide (08/03) 22 ww w Gar rett Com com .. 1. Using standard twisted pair media, insert either end of the cable with a RJ-45 plug into the RJ-45 connector of the port. Note that, even though the connector is shielded, either unshielded or shielded cables and wiring may be used.
Magnum P62-Series Hardened Switches Installation and User Guide (08/03) 23 ww w Gar rett Com com .. longer distances, about 20Km with the single-mode SC. The same procedures as for multi-mode fi ber apply to single-mode fiber connectors. Follow the steps listed in Section 3.
Magnum P62-Series Hardened Switches Installation and User Guide (08/03) 24 ww w Gar rett Com com .. 3.2.6 Connections to NICs w hich support Auto-Negotiation, RJ-45 ports The copper ports of Magnum P6.
Magnum P62-Series Hardened Switches Installation and User Guide (08/03) 25 ww w Gar rett Com com .. UL Requirements The following must be adhered to in order to conform to UL requirements: 1. Minimum 18 AWG cable for connection to a Centralized DC power source.
Magnum P62-Series Hardened Switches Installation and User Guide (08/03) 26 ww w Gar rett Com com .. Operating Shock and Vibration : meets Bellcore GR-63-CORE Sections 4.
Magnum P62-Series Hardened Switches Installation and User Guide (08/03) 27 ww w Gar rett Com com .. to be in contact with a vertic al surface (such as pedestal) that has good heat conducting properties. Remove rubber “feet”, if present, to enhance metal-to -metal contact and provide the best heat transfer aw ay from the PSX unit.
Magnum P62-Series Hardened Switches Installation and User Guide (08/03) 28 ww w Gar rett Com com .. 3.5 DIN-Rail mounting option for mP62 Series The Magnum P62-Series Ethernet “Outdoor” Sw itches are designed to operate in extended temperature applications and are suitable for us e in environments with inhospitable high / low temperatures.
Magnum P62-Series Hardened Switches Installation and User Guide (08/03) 29 ww w Gar rett Com com .. 4.0 OPERATION This section describes the function and ope ration of the Magnum P62-Series Switches. 4.1 Dual-Speed Functionality, and Switching The Magnum P62-Series Hardened Sw itch provide six 10/100 RJ-45 switched ports, and two 100Mb fiber ports.
Magnum P62-Series Hardened Switches Installation and User Guide (08/03) 30 ww w Gar rett Com com .. An address-aging algorithm causes least-us ed addresses to fall out in favor of new frequently-used addresses. To reset the address buffer, cycle power down-and-up.
Magnum P62-Series Hardened Switches Installation and User Guide (08/03) 31 ww w Gar rett Com com .. 5.0 TROUBLESHOOTING All Magnum Ethernet products are designed to provide reliability and consistently high performance in all network envir onments.
Magnum P62-Series Hardened Switches Installation and User Guide (08/03) 32 ww w Gar rett Com com .. 5.2 When Calling for Assistance Please be prepared to provide the following information. 1. A complete description of the problem, including the following points: a.
Magnum P62-Series Hardened Switches Installation and User Guide (08/03) 33 ww w Gar rett Com com .. GarrettCom will carefully test and evaluate all returned products, will re pair products that are un.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il GarrettCom P62-Series è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del GarrettCom P62-Series - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso GarrettCom P62-Series imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul GarrettCom P62-Series ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il GarrettCom P62-Series, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del GarrettCom P62-Series.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il GarrettCom P62-Series. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo GarrettCom P62-Series insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.