CONTROLLERS CP7317RS RS – 232 CONTROLLER USER’S GUIDE MANUAL PART NO. 400-0017-003 PRODUCT REVISION: 0.
CONTROLLERS 1 INTRODUCTION Thank you for purchasing the CP7317RS RS-232 Controller. We are sure you will find it a reliable and useful product. Superior performance for the right price backed by solid technical and customer support is what we have to offer.
CONTROLLERS 2 PRECAUTIONS / SAFETY WARNINGS 1 Please read this manual carefully before using your CP7317RS RS-232 Controller. Keep this manual handy for future reference. These safety instructions are to ensure the long life of your CP7317RS and to prevent fire and shock hazard.
CONTROLLERS 3 ABOUT CP7317RS - RS-232 CONTROLLER 2 The CP7317RS RS-232 Controller is designed to provide expanded capabilities to any control system. The CP7317RS is designed to accept RS- 232 commands from a control device and output those commands as relay contacts or digital high or low.
CONTROLLERS 4 CP7317RS DESCRIPTION 4 CP7317RS FEATURES 4.1 RS-232 PORT This port (located next to the power outlet) is a fully programmable, bi-directional, and full duplex port that has the ability to operate at any baud rate up to 9600. The general standard on transmission is 8 bits, no parity, and 1 stop bit.
CONTROLLERS 5 The following table shows the pin-outs on the connector corresponding to the following I/O port pin numbers. Connector Pin No. 1 2 3 4 5 6 7 8 9 I/O Port Pin No. 1 3 5 7 9 Ground 2 4 6 8 There are 4 ports with 8 I/O pins and one ground pin, #5 on each port.
CONTROLLERS 6 4.7 PROGRAMING COM MANDS The commands below are used for presetting the default status of the unit. Note: AFTER USING THE PROGRAMMING COMMANDS LISTED BELOW, THE CP7317RS SHOULD BE POWERED OFF AND THEN ON. [SETIp,b,n] This command sets individual pins of each I/O port to input or output status.
CONTROLLERS 7 b This letter defines the status of a pin, while its position in a string number corresponds to the pin number on the I/O Port of the CP7317RS . For example b 4 represents the status of Pin 4 on the I/O connector. The valid pins on I/O port are from 1 to 9 except 5.
CONTROLLERS 8 FIGURE 6: Input/Output Port Pin Configuration n This letter designates the status of the pin as either high or low during “Power up” of the unit. when n = 1 the pin is set as high when n = 0 the pin is set as low Example: Set pin 1 of port 3 as low during POWER ON.
CONTROLLERS 9 n This letter designates the status of the relay during “Power up”. n=1 relay is open n=0 relay is closed Example: Set relay 6 of port 2 to be open at power up.
CONTROLLERS 10 Bit No. Connector Pin No. 7 4 8 9 n Data that defines the status of the pin n=1 or n=0. [SETDp, b 1 b 6 b 2 b 7 b 3 b 8 b 4 b 9 ] SET all pins on the particular I/O port of the unit. This command defines if I/O port pins will be high or low.
CONTROLLERS 11 [READDp] Read Digital status of a particular port. The feedback is in the following format [10011100] 1 is for high 0 is for low. The feedback provides status of all pins. Left most character is a bit pin number 1. p Port number, this is an ASCII character from 1 to 4 that matches the port number on the back of the CP7317RS .
CONTROLLERS 12 4.10.1. MEMORY 1 I/O port/memory is A Sub-Register address is from 00 to 255 Sub-Register definitions 00 This location should be set to FFh i f memory initialization is required. During the power up sequence this location is checked for software revision.
CONTROLLERS 13 33 Power up status of relays on port 2,3,4. If bit is set to 0 then relay will be closed on power up. If bit is set to 1 then relay will be open on power up. 34 Left bracket for beginning command code. Factory set to “[“. 35 Right bracket for ending command code.
CONTROLLERS 14 08 00-07 locations for return code for port 1 pin 2 for transition from 0 to 1. This return code should include any necessary brackets. .
CONTROLLERS 15 ALTINEX POLICY 5 5.1 LIMITED WARRANTY Altinex warrants that its products and cables are free from defects in materials under normal use and service. This warranty is limited to repairing at company’s factory any part or parts of the product, which upon company’s examination shall disclose to be, thus defective.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Altinex RS 232 Controller CP7317RS è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Altinex RS 232 Controller CP7317RS - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Altinex RS 232 Controller CP7317RS imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Altinex RS 232 Controller CP7317RS ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Altinex RS 232 Controller CP7317RS, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Altinex RS 232 Controller CP7317RS.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Altinex RS 232 Controller CP7317RS. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Altinex RS 232 Controller CP7317RS insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.