Frymaster, a member of the Co mmercial Food Eq uipment Service Asso ciation, recomm ends using CFESA Certified Tec hnicians. 24-Hour Service Hotline 1-800-551-8633 APRIL 2009 *8196438* GF14 and GF40 S.
NOTICE This appliance is intended for professional use only and is to be operated by qualified personnel only. A Frymaster/DEAN Factory Authorized Service Center (FASC) or other qualified professional should perform installation, maintenance, and repairs.
DANGER Adequate means must be provided to limit the movement of this appliance without depending upon the gas line connection. Single fryers equipped with legs must be stabilized by installing anchor straps. All fryers equipped with casters must be stabilized by installing restraining chains.
i GF14 and GF40 SERIES GAS FRYERS TABLE OF CONTENTS CHAPTER 1: Service Procedures 1.1 Functional Description ......................................................................................... 1-1 1.2 Accessing Fryers for Servicing .............
1-1 GF14/GF40 SERIES GAS FRYERS CHAPTER 1: SERVICE PROCEDURES 1.1 Functional Description The GF14 and GF40 Series fryers contain a welded steel (stainless or cold-rolled) frypot that is heated by gas flames diffused over its lower surface by deflectors.
1-2 Thermostats 1. These fryers are equipped with adjustable opera ting thermostats. The tem perature at which the thermostat opens and closes is adjusted by rotating a knob. The tolerance band of the Sunne thermostat is +10°F (+6°C) and -20°F (-11°C ).
1-3 1.6 Adjusting the Pilot Flame 1. Remove the cap shown in the illustration below to access the pilot flame adjustm ent screw in the gas valve. Remov e this ca p to access t he pilot flame adjustm ent s c rew.
1-4 5. Straighten the clips that secure the thermostat bulb to the frypot. Use a slotted socket to unscrew the thermostat from the frypot. 6. Loosen the capillary tube compression nut (the sm all nut) on the replacem ent thermostat so that it slides freely on the capillary tube.
1-5 4. Ensure threads inside the fitting are clean and apply a small amount of Loctite™ PST56765 compound or equivalent to the threads of the ne w high-limit and screw it securely into the fry- pot. 5. Connect the wires to the gas valve terminals as shown in the illustration below (polarity does not matter).
1-6 1.7.4 Replacing the Gas Valve DANGER Drain the frypot or remove the handle from the drain valve before proceeding further. 1. Disconnect fryer from the gas supply. 2. Disconnect the wiring from the gas valve term inal block, m arking each wire to facilitate reconnection.
1-7 13. Remove the m anometer or pressure gauge fitting fr om the pressure tap hole and reinstall the pipe plug. 14. Place the gas valve in the PILOT position and check for gas leaks. If no leaks are found, re-light the pilot and return the unit to operation.
1-8 1: Remove these screws to release guard. 3: Pres s down o n t o p o f t herm opil e, for cing it out o f the pilot bra cket. 2: Bend this clip outward to rel ease th ermop ile. 3. To replace the complete pilot assembly: a. Disconnect the pilot tube from the bottom of the pilot assem bly.
1-9 7. Remove the screw from the frypot hold-down bracket located at the center of the cabinet cross brace. 8. Dismount the thermostat control from the thermostat bracket. 9. Disconnect the pipe union on the right side of the gas valve. 10. Lift the frypot assembly upward from the cabinet.
1-10 Pilot Does Not Remain Lit When Gas Valve Knob is Released The electromechanical Honeywell gas valve used on the GF14 and GF40 fryers has a pair of normally open coils (electromagnetic switches) that cl ose when low voltage is applied to them .
1-11 1.8.2 Improper Burner Functioning If the burner lights on one side only , the probable causes are a missing or m isaligned rear deflector or improper burner manifold pressure. Clogge d burner orifices are usually the cause of gaps in burner firing .
1-12 1.8.4 Leaking Leakage of the frypot almost always will be due to im properly sealed high-limits, therm ostats, or drain fittings. When installed or replaced, each of these com ponents must be sealed with Loctite™ PST56765 sealant or equivalent to prevent leakage.
2-1 GF14/GF40 SERIES GAS FRYERS CHAPTER 2: GF14/GF40 PARTS LIST 1/1/08 and Later 1 4 2 5 3 8 9 7 6 A CCESSORIES Item Part # Component 1 803-0015 Basket, Full 2 803-0032 Rack, basket suppor t, GF14 * 8.
2-2 Item Part # Component * 809-0171 Basket hanger screw (spacer 809- 092 1) * 803-01 88 Sediment tray, GF14 * 803-01 03 Sediment tray, GF40 Burners Item Part # Com p onent 1 200-0176 Bracket, Front M ani fol d Mounting 2 200-0177 Hanger, Rear Manifol d * 200-0749 Guard, Therm opile 3 Valve, Honeywell Millivolt Gas 807-1603 Natural (See NOTE 2 .
2-3 Item Part # Com p onent * 826-11 40 GF14 Conversion Kit, LP t o Natural * 826-11 43 GF40 Conversion Kit, Natu ral to LP * 826-11 44 GF40 Conversion Kit, LP t o Natural 6 Pilot Assembly (Includes bracket, hood, and thermopile. 810- 2071 Natural Gas w /.
2-4 Cabinetry Item Part # Component 1 200-6903 Back 2 816-0656 Insulat ion, back Sides 3 201-6917 Side, left, stai nless 4 202-6917 Side, right, stainless * 212-6893 Right, painte d * 211-6893 Left, p.
2-5 Frypots Item Part # GF14 Frypot Components 1 823-1024 Flue assembly 2 823-6655 Frypo t * 823-4493 Sysco-brande d fryers 8 06- 7972 O perating thermostat (S ysco fryer) 3 106-0770 Therm ostat * 826-1177 Hi -limi t * 807-1692 Ope rating thermost at * 9 10-2113 Target, rear, GF14 * 810-1569 Valve, 1.
2-6 Item Part # GF40 Frypot Components 1 806-5567 Flue 2 823-6667 Frypot 3 826-1177 Hi-limit thermo stat * 807-1692 Operating therm ostat * 810-1569 Valve, 1.
THIS PAGE INTENTIONALLY LEFT BLANK.
Frymaster, L.L.C., 8700 Line Av enue, Shrev eport, Louisiana 71106 TEL 1-318-865-1711 FAX (Parts) 1-318- 219-71 40 FAX (Tech Support) 1-318-219-7135 PRINTED IN THE UNITED STATES SERVICE HOTLINE 1-800-.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Frymaster FRYMASTER GF40 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Frymaster FRYMASTER GF40 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Frymaster FRYMASTER GF40 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Frymaster FRYMASTER GF40 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Frymaster FRYMASTER GF40, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Frymaster FRYMASTER GF40.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Frymaster FRYMASTER GF40. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Frymaster FRYMASTER GF40 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.