Manuale d’uso / di manutenzione del prodotto RC 21 del fabbricante Friedrich
Vai alla pagina of 26
Enviromaster International LLC 5780 Success Dr. Rome, NY 13440 www.retroaire.com INST ALLA TION, OPERA TION AND MAINTENANCE MANU AL An ISO 9001-2000 Certified Company DUAL MOTOR P A CKA GED TERMINAL AIR CONDITIONERS RC 1 1, 12 & 21 RC/RH 10, 20, 35, 45, 80, 90 P/N# 240004146, Rev .
2 www .retroaire.com The Right Fit For Comfort INST ALLA TION, OPERA TION, AND MAINTENANCE MANUAL P/N# 240004146, Rev . 1.7 [02/07] This manual is intended as an aid to qualified service personnel for proper installation, operation, and mainte- nance of the RetroAire Dual Motor Packaged T erminal Air Conditioner (PT AC).
3 www .retroaire.com The Right Fit For Comfort INST ALLER RESPONSIBILITIES T his manual has been prepared to acquaint you with the installation, operation and maintenance of RetroAire Dual Motor PT ACs and to provide important safety information in these areas.
4 www .retroaire.com The Right Fit For Comfort The RetroAire Dual Motor PT AC is available in nominal sizes of 9,000 Btuh, 12,000 Btuh, 15,000 Btuh, and 18,000 Btuh.* With energy efficiency ratings as high as 10, the replacement of worn out and inefficient units is a very at - tractive option.
5 www .retroaire.com The Right Fit For Comfort PREP ARA TION FOR INST ALLA TION IMPORT ANT : RetroAire Dual Motor PT ACs are to be used with metal wallsleeves. The sleeves must employ front pane ls secur ed by screws th at preve nt conta ct with al l parts with minor dimensions of openi ngs not exceed ing 1/2”.
6 www .retroaire.com The Right Fit For Comfort EV AP BLOCK OFF Install 1/2” x 1/2” Foam T ape 1. Take uni t o ut of packaging. 2. Sl id e uni t in to w al l sle ev e.
7 www .retroaire.com The Right Fit For Comfort RC1 1 PERFORMANCE DA T A* UNIT SIZE COOLING BTUH EER FRESH AIR CFM 9 9500 10 40/35 12 1 1,900 10 40/35 15 14,700 9.2 40/35 18 16,900 9.1 40/35 1. Take uni t o ut of packaging. 2. Slide unit into wall sleeve.
8 www .retroaire.com The Right Fit For Comfort INST ALLA TION INSTRUCTIONS 1. Take uni t o ut of packaging. 2. Slide unit into wall sleeve. The supply duct on the cool - ing chassis should line up with the supply vent on the room cabinet. The weather angles should require no adjustment.
9 www .retroaire.com The Right Fit For Comfort AIR INT AKE FIL TER 5 1/2” 8 1/2” 35 15/16” 4” 3” 2” REMOVEABLE WEA THER SEAL ANGLES 22” CONDENSER COIL 14 13/16” A 18 1/8” 8 1/4” 26.
10 www .retroaire.com The Right Fit For Comfort Hydronic Only: Remove the 2-position connector as- sembly from kit bag supplied with unit (this will have 2 yellow wires attached) . Con nect this 2-p ositio n conn ec- tor to the 2-position connection located on the bottom of the control box panel.
1 1 www .retroaire.com The Right Fit For Comfort RC21 REPLACEMENT PT AC INST ALLA TION INSTRUCTIONS 1. Take uni t o ut of packaging. 2. Slide unit into wall sleeve. If supply duct on cooling chassis does not line up with supply vent on room cabinet it is possible that factory instlled angle brackets on the top and sides will have to be reversed.
12 www .retroaire.com The Right Fit For Comfort 6. 1” x 1” Open cell foam strips are provided to prevent outside air from entering around the chassis to the room from the sides and top of the cabinet. Install between wall sleeve and cooling chassis.
13 www .retroaire.com The Right Fit For Comfort *Refer to the charts on page 23 for electrical and optional electric heat specifications. 1. Take uni t o ut of packaging. 2. Slide unit into wall-sleeve. The supply duct on the cool - ing chassis should line up with the supply vent on the room cabinet.
14 www .retroaire.com The Right Fit For Comfort RC/RH45 REPLACEMENT PT AC INST ALLA TION INSTRUCTIONS 1. Take uni t o ut of packaging. 2. Slide unit into wall slee ve.
15 www .retroaire.com The Right Fit For Comfort Front V iew Cooling Chassis W all Sleeve 1 x1 Foam T ape RC/RH45 PERFORMANCE DA T A* Unit Size Cooling Btuh EERs Heat Pump Btuh COP Fresh Air CFM 9 9,500 10 8500 2.8 40/35 12 1 1,900 10 1 1400 2.
16 www .retroaire.com The Right Fit For Comfort RC/RH80 REPLACEMENT PT AC INST ALLA TION INSTRUCTIONS Air Filter 8”x30” Permanent Aluminum Mesh 1. Take uni t o ut of packaging. 2. Slide unit into wall sleeve. The supply duct on the cooling chassis should line up with the supply vent on the room cabinet.
17 www .retroaire.com The Right Fit For Comfort RC/RH80 INST ALLA TION INSTRUCTIONS (Continued) RC/RH80 Performance Date* UNIT SIZE COOLING BTUH EER HEA T PUMP BTUH COP FRESH AIR CFM 9 9,500 10 8500 2.8 40/35 12 1 1,900 10 1 1400 2.9 40/35 15 14,700 9.
18 www .retroaire.com The Right Fit For Comfort IMPORT ANT : The RC/RH90 chassis is 18 1/4” deep for the 9,000, 12,000, and 15,000 Btuh models. The standard depth for the 18,000 Btuh is 24”. However , EMI can supply it for an 18 1/4” chassis on demand.
19 www .retroaire.com The Right Fit For Comfort RC/RH90 FINAL INSPECTION AND ST ART -UP ( All other units see “Final Inspecton and Startup” page 20) 1. Mount control box in wall sleeve (in the same location as the old control box) 2. Make sure the chassis is level.
20 www .retroaire.com The Right Fit For Comfort 1. Make sure the chassis is level. Check by pouring water into the drain pan and making certain it flows through the drain hoses to the condenser side of the unit. 2. Plug or hard wire line voltage to unit.
21 www .retroaire.com The Right Fit For Comfort controls will power a normally closed valve that is the same voltage as the unit (ex: a unit rated 208/230 V will power a 208/230 V normally closed valve). Be sure to check the wiring diagram (located on the unit) and voltage application for the specific unit.
22 www .retroaire.com The Right Fit For Comfort SEQUENCE OF OPERA TION (CONTINUED) CHOOSING A THERMOST A T : EMI offers a thermostat that is compatible with your PT AC/PTHP unit. Select EMI part number 240-2960 from the latest Retroaire price list for this option.
23 www .retroaire.com The Right Fit For Comfort HP HP SEQUENCE OF OPERA TION (CONTINUED) condition be detected, the compressor and condenser fan will be swi tch ed off fo r a min imu m of th ree minu tes and unti l the freeze condition is satisfied. During this time the indoor fan will continue to run to aid in the defrost process.
24 www .retroaire.com The Right Fit For Comfort 1 1. Replace panels and reconnect electrical power . 12. T est unit operation. CLEANING THE EXTERIOR 1. Clean the air filter at least once a month by removing it from the unit and washing or vacuuming any dust from its surface.
25 www .retroaire.com The Right Fit For Comfort Due to EMI’s ongoing development programs, design, specifications, and performance data may change without notice.
26 www .retroaire.com The Right Fit For Comfort ALL PRODUCT LIMITED W ARRANTY Enviromaster International LLC (EMI) warrants to the purchaser/owner that EMI products will be free from defects in materi.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Friedrich RC 21 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Friedrich RC 21 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Friedrich RC 21 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Friedrich RC 21 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Friedrich RC 21, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Friedrich RC 21.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Friedrich RC 21. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Friedrich RC 21 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.