Manuale d’uso / di manutenzione del prodotto MW24Y3H del fabbricante Friedrich
Vai alla pagina of 28
SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED TYPE Indoor unit Outdoor unit MW18Y3H MW24Y3H MR18Y3H MR24Y3H CONTENTS SPECIFICATIONS .................... 1 DIMENSIONS ........................ 2 REFRIGERANT SYSTEM DIAGRAM ..... 4 CIRCUIT DIAGRAM ........
2010.02.26 1 INDOOR UNIT HxWxD HxWxD 12-5/8 x 39-1/4 x 9 inch 320 x 998 x 228 mm OUTDOOR UNIT 32-3/4 x 35-3/8 x 13 inch 830 x 900 x 330 mm DIMENSIONS INDOOR UNIT Shipping / Net Shipping / Net 40 lbs /.
DIMENSIONS Unit : inch (mm) Drain pipe diameter Inside : 5/8 inch (16 mm) Outside : 1-3/32 inch (28 mm) Liquid pipe diameter : 3/8 inch (9.52 mm) Gas pipe diameter : 5/8 inch (15.88 mm) INDOOR UNIT 39-1/4" (998) 9" (228) 12-5/8" (320) 2010.
Unit : inch (mm) OUTDOOR UNIT 3"(77) 35-1/2" (900) 32-3/4" (830) 17-3/8" (440) 7/8" (21) 3/8" (9) 15-3/4" (400) 13" (330) 1-1/4" (31) 1/2" (12) 7-3/4" (196) 5-3/4" (147) 6-3/4" (170) 3-7/8" (99) 14-5/8" (370) 25-5/8" (650) Air Flow 2010.
REFRIGERANT SYSTEM DIAGRAM 3-Way valve (Small) 3-Way valve (Large) Strainer Strainer Muffler Pressure switch 4-Way valve Expansion valve Heat exchanger ( INDOOR ) Heat exchanger ( OUTDOOR ) Sub-accumulator Compressor Refrigerant pipe diameter Liquid : 3/8" (9.
RED RED BROWN BROWN BLUE BLUE BLACK BLACK BROWN BROWN BLACK BLACK WHITE YELLOW ORANGE BLUE BROWN RED BROWN YELLOW WHITE BLACK RED RED GREEN WHITE BLACK WHITE BLACK VIOLET WHITE BLACK WHITE WHITE WHITE.
L1 L2 3 2 1 G G POWER SOURCE 7 6 5 4 3 2 1 7 6 5 4 3 2 1 7 6 5 4 3 2 1 5 4 3 2 1 3 2 1 3 2 1 2 1 2 1 2 1 3 2 1 5 4 3 2 1 5 4 3 2 1 6 5 4 3 2 1 6 5 4 3 2 1 6 5 4 3 2 1 6 5 4 3 2 1 5 4 3 2 1 1 2 3 4 5 6.
CN1 1-2 WHITE CN1 1-1 RED CN1 1-3 WHITE CN1 1-4 WHITE CN1 1-5 WHITE CN1 1-6 WHITE CN1 1-7 WHITE CN3-2 WHITE CN3-1 RED CN2-2 BLACK CN2-1 BLACK CN13-1 CN13-5 CN13-4 CN13-3 CN13-2 BLACK BLACK CN10-3 WHIT.
5V 12V R88 1.0k <1/10W> C57 0.01 <B> IC 7 - 2 uLN2003ADR L4 0R0 C51 0.01 <B> K10 G5NB-1A L3 0R0 R101 330 <1/10W> CN14 B3B-XH-AM CN16 B2B-XH-A 21 5 4 2 3 1 3 4 2 1 IC 1 - 6 3 I .
CN201 07 JB20 / P AP 1061 L=230 5V C201 0.1 <F> 5V + C202 47/ 10V R201 47 <1/4W> I C201 GP1UM261RKVF 5V D201 SLR-325MC D203 SLR-325MC D202 SLR-325DC 5 4 6 1 2 3 7 2 1 3 VCC OUT GND GREEN ORANGE GREEN INDOOR UNIT INDICA TOR PCB ASSEMBL Y K05CY -0902HSE-D0 2010.
INVERTER ASSEMBL Y MR18Y3H : EZ-009SHUE MR24Y3H : EZ-009THUE OUTDOOR PCB CIRCUIT DIAGRAM 2010.03.01 10 D100 D25XB60 + - 2 3 1 4 EMI FIL TER ZCA T2132-1130 1T COMPRESSOR UL3271 AWG1 4 x3 RED WHITE BLAC.
5V 5V R40 10k <1/10W> D670 DAN217U 3 21 R41 1.0k <1/10W> C42 1000p <B> C670 0.1 <F> R674 1.0k <1/10W> R84 1.0k <1/10W> 5V R85 4.
37 23 22 21 24 25 26 27 28 36 35 34 33 32 31 38 13 15 20 16 18 7 9 10 12 1 3 4 6U P VP1 VUFB VUFS VP VP1 VVFB VVFS WP VP1 VNO VWFB VWFS NC NW NV NU W V U P WN VN UN FO CFO CIN VNC VN1 - + 7 5 6 + - 1 3 2 3 2 1 3 2 1 IP M - G I PM-G I PM-G POWER-GND POWER-G R55 0R0 C50 0R0 I P M-GND I C70-2 BA2903F-E2 C161 0.
12V K101 G4A-1A or DW12D1 C108 3.3 <LE> L102 N200500K1D7C-02N R101 ZPR0RCH400 PTC THERMISTOR 12V L101 RCH3818-022PF07 C106 3.3 <LE> 4 3 12 3 2 4 1 4 3 L100 RCH3818-022PF07 12 C103 3.3 <LE> C104, C105 0.022 <YE> x2 C100 3.3 <LE> SA100 RA-302M V A100, V A101 470V <TNR> x2 F101 5.
12V K101 G4A-1A or DW12D1 C108 3.3 <LE> L102 N200500K1D7C-02N 12V L101 RCH3818-022PF07 C106 3.3 <LE> 4 3 12 3 2 4 1 4 3 L100 RCH3818-022PF07 12 C103 3.3 <LE> C104, C105 0.022 <YE> x2 C100 3.3 <LE> SA100 RA-302M V A100, V A101 470V <TNR> x2 F101 5.
W7 B YELLOW W8 B BLUE W12 B WHITE W13 B VIOLET P N + + + C200 - C202 660/ 450V x3 POWER_G W7 B YELLOW W8 B BLUE W12 B WHITE W13 B VIOLET P N + + POWER_G MR24Y3H CAP ACITOR PCB ASSEMBL Y K05FB-0903HUE-P0 OUTDOOR UNIT MR18Y3H CAP ACITOR PCB ASSEMBL Y K05FB-0902HUE-P0 2010.
ERROR DETECTION Error Operation LED Timer LED Serial signal error Normal 2 flash 3 flash 4 flash 5 flash Serial signal (reverse) error, at operation start up Serial signal (reverse) error, during oera.
LED OUTDOOR UNIT 0.5 second on / 0.5 second off on 0.1 second on / 0.1 second off 2.0 second on / 2.0 second off IPM overcurrent protection Discharge temperature abnormal Thermistor abnormal CT abnormal 0.1 second on / 2.0 second off 5.0 second on / 5.
2010.02.26 18 PARTS INDOOR UNIT 4 3 4 6 2 1 5 5 1 Front Panel Total Assy 9315335258 2 Front Panel 9314991080 3 Intake Grille Assy 9315336064 4 Air Filter 9315014016 5 Clamper Grille 9306755010 6 Recei.
16 18 24 25 19 13 22 20 15 21 23 2010.02.26 19 INDOOR UNIT 11 17 14 26 27 12 Ref Descriprion Part number 24 Diffuser Z 9315003010 22 Louver Z 9315001016 23 Diffuser U 9315002013 25 Spring C 9314142017.
2010.02.26 20 34 31 40 39 38 32 36 37 35 33 INDOOR UNIT 39 Bearing C Assy 9306628017 31 Evaporator Total Assy 9315338020 40 Room Therimistor Holder 9315252012 32 Water Seal 9315251015 33 Evaporater Ho.
INDOOR UNIT 21 2010.02.26 47 49 51 44 46 45 50 43 41 42 48 41 Controller PCB (18) Controller PCB includes a room thermistor. 9708065168 41 Controller PCB (30) 9708065182 41 Controller PCB (24) 9708065.
OUTDOOR UNIT P ARTS 2010.02.26 22 5 6 4 3 2 1 1 Top Panel Sub Assy 9374417032 2 Front Panel Sub Assy 9374414079 -- Protective Net 9375381011 -- Drain Assy 9303029015 -- Drain Cap 313166024302 3 Service Panel Sub Assy 9374415052 5 Right Panel Sub Assy 9374416134 4 Emblem Rear 9375212032 6 Valve Cover 9374174010 Ref.
OUTDOOR UNIT 2010.02.26 23 15 14 16 13 12 11 17 14 Motor Bracket Sub Assy 9374418152 16 Propeller Fan Assy 9366378020 17 Valve Plate 9374099030 15 Fan Motor 9602843015 13 Condenser A Assy 9374433056 12 Separate Wall Sub Assy 9374413188 11 Base Assy 9374166206 Ref.
OUTDOOR UNIT 2010.02.26 24 30 26 21 31 22 23 27 25 24 32 29 28 Ref. 21 Strainer Assy 9372524015 22 3-Way Valve Sub Assy 9377958013 23 3-Way Valve Assy 9377959010 24 Check Joint Assy 9372802038 25 Comp.
OUTDOOR UNIT 2010.02.26 25 52 53 54 49 47 44 46 50 45 51 43 42 48 41 Connector : Blue Connector : Orange Connector : Green Connector : Red 41 PCB Case Assy 9375316020 42 Inverter Case 9375314019 43 AC.
9305642045 Remote control holder Name and Shape Part number 9315023018 9379219013 0600185534 0700076046 9310519004 9312153060 9311925071 Remote control Battery (penlight) Cloth tape Tapping screw (big.
1002G3767.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Friedrich MW24Y3H è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Friedrich MW24Y3H - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Friedrich MW24Y3H imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Friedrich MW24Y3H ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Friedrich MW24Y3H, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Friedrich MW24Y3H.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Friedrich MW24Y3H. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Friedrich MW24Y3H insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.