CONTENTS SPECIFICATIONS ................................ 1 OUTLINE AND DIMENSIONS ..................... 2 REFRIGERANT SYSTEM DIAGRAM .............. 4 ERROR CONTENTS ............................ 7 CIRCUIT DIAGRAM .............................. 5 PCB CIRCUIT DIAGRAM .
SPECIFICA TIONS TYPE INDOOR UNIT OUTDOOR UNIT COOLING CAP ACITY PO WER SOURCE FREQUENCY RUNNING CURRENT (Heat) INPUT W A TTS (Heat) E.E.R. (Heat) MOISTURE REMO V AL AIR CIRCULA TION-High ELECTRICAL DA.
OUTLINE AND DIMENSIONS INDOOR UNIT Unit : inch (mm) 39-1/8" (990) 19-3/4" (500) 4-23/32" (120) 35" (900) 25-7/8" (655) 20-7/8" (530) 7-27/32" (199) 2-3/4" (70) 7-7/8" (200) 6-7/8" (175) 7-7/8" (199) (rear view) 2 2006.
Unit : inch (mm) OUTDOOR UNIT 3"(77) 35-1/2" (900) 32-3/4" (830) 17-3/8" (440) 7/8" (21) 3/8" (9) 15-3/4" (400) 13" (330) 1-1/4" (31) 1/2" (12) 7-3/4" (196) 5-3/4" (147) 6-3/4" (170) 3-7/8" (99) 14-5/8" (370) 25-5/8" (650) Air Flow 3 2006.
REFRIGERANT SYSTEM DIAGRAM : COOL : HEAT Evaporator OUTDOOR UNIT Pressure Check Valve Condenser 4-way Valve High Pressure Switch Accumulator Muffler Compressor Expansion Valve Refrigerant Pipe 9.52mm (3/8") Charging Valve Charging Valve Refrigerant Pipe 15.
CIRCUIT DIAGRAM INDOOR UNIT TERMINAL STEP MO T OR ( LEFT / RIGHT ) STEP MO T OR (U P/D O W N) F A N M OTO R CAP A CITOR F A N M OTO R ROOM TEMPERA TURE THERMIST OR PIPE TEMPERA TURE THERMISTOR FM M M 1 2 31 2 3 Use T3.
OUTDOOR UNIT ORANGE YELLOW WHITE BLUE BRO WN RED BLUE YELLOW WHITE BLACK RED BLACK BLACK RED RED BLACK BRO WN BLUE BRO WN BLACK RED BRO WN BLACK BLACK WHITE BLACK BLACK WHITE WHITE GREEN BLACK WHITE B.
CONTROLLER PCB ASSY K01AL-050SHSE-C1 INDOOR PCB CIRCUIT DIAGRAM 7 2006.05.25.
POWER SUPPL Y PCB ASSY K04BA-0500HUE-P0 CONTROLLER PCB ASSY K04A W-0502HUE-C1 INVERTER ASSEMBL Y EZ-005FHUE OUTDOOR PCB CIRCUIT DIAGRAM 8 2006.05.25.
600/450V x 4 OUTDOOR UNIT CONTROLLER PCB ASSEMBL Y K04A W-0502HUE-C1 9 2006.05.25.
5V TM101 TM102 C1 12 0.015 <YE> C1 13 0.015 <YE> C1 1 1 3.3 <LE> L4 RCH4730-021PF07 C107 3.3 <LE> TM100 L2 N200500K1D7C CT1 CT -1B 5V D60 DAN217U C64 0.1 <F> R68 22K <1/10W> C65 0.1 <F> VR1 B2K + R61 3.74K <1/10W> (1%) C60 220/16V <PJ> R60 1.
ERROR CONTENTS (Indoor unit) Operation can be checked by lighting and flashing of the display section OPERATION, , and TIMER lamps. Perform judgment in accordance with the following.
ERROR CONTENTS (outdoor unit) 1. Make a TEST RUN in accordance with the in- stallation instruction sheet for the indoor unit. 2. OUTDOOR UNIT LEDS Error contents Communication error (Indoor unit - Out.
DISASSEMBLY ASSEMBLY INDOOR UNIT 13 2006.05.25 653-2 365-1 365-2 365-2 365-1 870-1 653-2 870-1 509 173 580 508 174 240 743.
14 2006.05.25 INDOOR UNIT 196-1 184-1 470 764 577 127 124 235 124 108 68 578 418 160 439 138 68 187.
15 2006.05.25 983 983 INDOOR UNIT.
416 417 385 771 488 472 473 443 8-1 16 2006.05.25 INDOOR UNIT.
17 2006.05.29 800 652-1 735 146 OPTIONAL P AR TS INDOOR UNIT.
18 2006.06.13 INDOOR UNIT 982.
684 558 555 554 520 521 505 505 505 321 320 361 69 69 69 69 502 505 506 500 407 408 503 876-2 876-1 361-2 361-2 361-2 361-3 361-3 361-3 361-2 19 2006.05.
1 6 3 4 5 2 20 2006.05.29 OUTDOOR UNIT.
17 18 10 13 11 9 15 14 8 OUTDOOR UNIT 2006.06.13 21.
22 23 31 20 29 12 28 12 19 24 26 27 25 30 22 2006.05.29 OUTDOOR UNIT.
37 38 33 34 36 35 23 2006.05.29 OUTDOOR UNIT.
PARTS LIST INDOOR UNIT Ref. Part No. Ord. Ref. Part No. Ord. No MS24Y3F Q'ty No MS24Y3F Q'ty 8-1 Air Filter 67220192 500 Protect Cover 67220242 34 Capacitor (Fan Motor) 67220218 502 SupportS.
OUTDOOR UNIT Ref. Part No. Ord. No MR24UY3F Q'ty 1 Top Panel Sub Assy 67201640 2 Front Panel 67201601 3 Fan Guard 67201602 4 Grip Side 67201603 5 Service Panel Sub Assy 67201688 6 Right Panel 672.
1 1 2 1 1 1 4 4 1 1 4 2 6 1 1 1 1 Q'ty INDOOR UNIT ACCESSORIES Name and Shape Part No. Application For positioning the indoor unit. For under ceiling type. For suspending the indoor unit from ceiling. For suspending the indoor unit on the wall. For fixing the wall bracket.
1 1 2 2 For remote control unit holder installation Use for air conditioner operation (AR-JW5) For remote control unit Use are remote control unit holder 9371190051 0600185534 9305642014 0700019098 Remote control unit holder Tapping screw Remote control unit Battery (penlight) Q'ty REMOTE CONTROL UNIT Name and Shape Part No.
0605G3090.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Friedrich MS24Y3F è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Friedrich MS24Y3F - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Friedrich MS24Y3F imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Friedrich MS24Y3F ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Friedrich MS24Y3F, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Friedrich MS24Y3F.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Friedrich MS24Y3F. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Friedrich MS24Y3F insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.