Manuale d’uso / di manutenzione del prodotto MR30C3F del fabbricante Friedrich
Vai alla pagina of 27
SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED type CONTENTS SPECIFICATIONS .................... 1 DIMENSIONS ....................... 2 REFRIGERANT SYSTEM DIAGRAM .... 4 CIRCUIT DIAGRAM .................. 5 ERROR CONTENTS ................ 6 INDOOR PCB CIRCUIT DIAGRAM .
1 2006.03.15 SPECIFICATIONS INDOOR UNIT MW30C3F OUTDOOR UNIT MR30C3F COOLING CAPACITY 30,700 BTU/hr POWER SOURCE 208 V / 230 V FREQUENCY 60 Hz RUNNING CURRENT 15.
OUTLINE AND DIMENSIONS Unit : inch (mm) INDOOR UNIT Model : MW30C3F 39-1/4" (998) 9" (228) 12-5/8" (320) 2 2006.02.22.
Unit : inch (mm) OUTDOOR UNIT Model : MR30C3F 3"(77) 35-1/2" (900) 32-3/4" (830) 17-3/8" (440) 7/8" (21) 3/8" (9) 15-3/4" (400) 13" (330) 1-1/4" (31) 1/2" (12) 7-3/4" (196) 5-3/4" (147) 6-3/4" (170) 3-7/8" (99) 14-5/8" (370) 25-5/8" (650) Air Flow 3 2006.
REFRIGERANT SYSTEM DIAGRAM 3-Way valve (Small) 3-Way valve (Large) Strainer Strainer Muffler Pressure switch 4-Way valve Expansion valve Heat exchanger ( INDOOR ) Heat exchanger ( OUTDOOR ) Sub-accumulator Compressor Cooling MW30C3F / MR30C3F Models : Refrigerant pipe diameter Liquid : 3/8" (9.
CIRCUIT DIAGRAM 2006.02.22 5.
CN1 1 B07B-9ASK CN201 JB20-07HG CN1 1-1 RED CN1 1-2 WHITE CN1 1-3 WHITE CN1 1-4 WHITE CN1 1-6 WHITE CN1 1-7 WHITE CN1 1-5 WHITE 1 2 3 4 5 6 7 1 2 3 4 5 6 7 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 6 1 .
5V VA 6 470V <TNR> R106 1.0K </2W>8 TM2 (3) D14 DAN202K Q1 1 DTC124EUA 1 2 3 3 2 1 2 3 1 Q10 DTC124EUA C54 0.01 <B> R1 14 390 <1/10W> 10 5 4 3 21 14 18 8 27 6 5 4 I C26-14 I C26-10 3 2 1 I C1-6 I C1-47 I C1-46 R105 10K <1/10W> 5V C50 0.
CN201 5V C201 0.1 <F> 5V + C202 47/ 10V R201 47 <1/4W> I C201 GP1UM261R 5V D201 SLR-325 D203 SLR-325 D202 SLR-325 5 4 6 1 2 3 7 2 1 3 VCC OUT GND INDICA T OR PCB ASSY K05CY -0500HSE-D0 8 2006.
TR PCB ASSY ( I P M ) K05CZ-0503HUE-TR0 CAP ACITOR PCB ASSY K05FB-0500HUE-P0 ACTPM CONTROLLER PCB ASSY K05CU-0503HUE-C1 POWER SUPPL Y PCB ASSY K05CW-0503HUE-FL0 INVERTER ASSEMBL Y EZ-00502HUE Model : MR30C3F OUTDOOR PCB CIRCUIT DIAGRAM 9 2006.
C64 10K <1/10W> C64 10K <1/10W> CONTROLLER PCB ASSY K05CU-0503HUE-C1 Model : MR30C3F 10 2006.03.15.
TR PCB ASSY ( I P M ) K05CZ-0503HUE-TR0 Model : MR30C3F 11 2006.03.15.
POWER SUPPL Y PCB K05CW-0503HUE-FL0 Model : MR30C3F 2006.02.22 12.
B B W13 VIOLET W12 WHITE R200 220K <2W> C200 C201 C202 C203 + + + + 660 / 450V x 4 SMOOTHING CIRCUIT B B W8 BLUE W7 YELLOW CAP ACITOR PCB ASSEMBL Y K05FB-0500HUE-P0 13 2006.
ERROR CONTENTS Error Operation LED Timer LED Serial signal error Normal 2 flash 3 flash 4 flash 5 flash Serial signal (reverse) error, at operation start up Serial signal (reverse) error, during oerat.
4 2 2 4 6 1 5 5 2006.03.15 15 DISASSEMBLY ILLUSTRATION Model : MW30C3F.
2006.02.22 16 Models : MW30C3F 8 31 35 36 34 29 30 27 25 28 32 33 9.
26 23 22 Model : MW30C3F 2006.03.31 17 10.
Model : MW30C3F 18 2006.06.13 46 48 52 55 40 42 41 53 39 37 38 47.
Model : MR30C3F 19 2006.05.12 6 11 7 5 2 4 3 1.
20 2006.05.12 9 8 10 13 15.
21 2006.05.12 24 21 27 25 12 28 17 18 26 20 19 29 23 22 26.
22 2006.06.13 46 47 48 41 34 39 36 38 42 37 45 35 33 40 31 CONNECTOR : BLUE CONNECTOR : ORANGE DISCHARGE TEMP THERMISTOR OUTDOOR TEMP THERMISTOR CONNECTOR : GREEN COMPRESSOR TEMP THERMISTOR CONNECTOR .
3$576/,67 ,1'22581,7 5HI 3DUW1R 2UG 1R 0:&) 4W )52173$1(/727$/$66< ,17$.
287'22581,7 5HI 3DUW1R 2UG 1R 05&) 4W 7233$1(/68%$66< )52173$1(/0 )$1*8$5' .
9305642045 Remote control unit holder Name and Shape Part No. 9315023018 9315027160 0600185534 0700076046 9310519004 Remote control unit Battery (penlight) Cloth tape Tapping screw (big) Wall hook bracket STANDARD ACCESSORIES Tapping screw (small) 0700019036 25 2006.
0602G3030.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Friedrich MR30C3F è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Friedrich MR30C3F - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Friedrich MR30C3F imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Friedrich MR30C3F ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Friedrich MR30C3F, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Friedrich MR30C3F.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Friedrich MR30C3F. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Friedrich MR30C3F insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.