Manuale d’uso / di manutenzione del prodotto MR24UY3F del fabbricante Friedrich
Vai alla pagina of 25
SPLIT TYPE AIR CONDITIONER (60Hz) CASSETTE type Models Indoor unit Outdoor unit MC24Y3F MR24UY3F CONTENTS SPECIFICATIONS ...................... 1 DIMENSIONS .......................... 2 REFRIGERANT SYSTEM DIAGRAM ....... 4 CIRCUIT DIAGRAM ............
INDOOR UNIT HxWxD DIMENSIONS INDOOR UNIT Gross / Net Gross / Net OUTDOOR UNIT WEIGHT POWER SOURCE COOLING RUNNING CURRENT HEATING INPUT WATTS COOLING HEATING E.
INDOOR UNIT unit : inch (mm) DIMENSIONS 2006.05.18 2 9-3/4" (246) 9-1/4" (235) 9-25/32" (248.5) 11-3/4" (298.5) 12" (305.5) 1-3/16" (30) 37" (940) 37" (940) 2-3/8" (60) Drain inside Dia. ø1-1/4" (ø32) outside Dia.
OUTDOOR UNIT unit : inch (mm) 2006.05.18 3 3"(77) 35-1/2" (900) 32-3/4" (830) 17-3/8" (440) 7/8" (21) 3/8" (9) 15-3/4" (400) 13" (330) 1-1/4" (31) 1/2".
Evaporator OUTDOOR UNIT Pressure Check Valve Condenser 4-way Valve High Pressure Switch Accumulator Muffler Compressor Expansion Valve Refrigerant Pipe 9.52mm (3/8") Charging Valve Charging Valve Refrigerant Pipe 15.88mm (5/8") INDOOR UNIT Strainer Strainer REFRIGERANT SYSTEM DIAGRAM : COOL : HEAT 2006.
CIRCUIT DIAGRAM INDOOR UNIT 2006.05.18 5 YELLOW YELLOW BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK PURPLE BLUE RED WHITE WHITE RED RED WHITE WHITE WHITE GREEN / YELLOW WHITE WHITE YELLOW YEL.
OUTDOOR UNIT 2006.05.18 6 ORANGE YELLOW WHITE BLUE BRO WN RED BLUE YELLOW WHITE BLACK RED BLACK BLACK RED RED BLACK BRO WN BLUE BRO WN BLACK RED BRO WN BLACK BLACK WHITE BLACK BLACK WHITE WHITE GREEN .
Model : MC24Y3F CONTROLLER PCB ASSEMBL Y K01AL-050LHSE-C1 2006.05.25 7 INDOOR PCB CIRCUIT DIAGRAM.
Model : MR24UY3F POWER SUPPL Y PCB ASSY K04BA-0500HUE-P0 CONTROLLER PCB ASSY K04A W-0502HUE-C1 INVERTER ASSEMBL Y EZ-005FHUE 2006.05.25 8 OUTDOOR PCB CIRCUIT DIAGRAM.
600/450V x 4 2006.05.25 9 CONTROLLER PCB ASSEMBL Y K04A W-0502HUE-C1 Model : MR24UY3F.
5V TM101 TM102 C1 12 0.015 <YE> C1 13 0.015 <YE> C1 1 1 3.3 <LE> L4 RCH4730-021PF07 C107 3.3 <LE> TM100 L2 N200500K1D7C CT1 CT -1B 5V D60 DAN217U C64 0.1 <F> R68 22K <1/10W> C65 0.1 <F> VR1 B2K + R61 3.74K <1/10W> (1%) C60 220/16V <PJ> R60 1.
ERROR CONTENTS (indoor unit) SU MO TU WE TH FR SA (1) Stop the air conditioner operation. (2) Press the master control button and the fan control button simultane- ously for 2 seconds or more to start the test run. Unit number (usually 0) Error code (3) Press the start/stop button to stop the test run.
ERROR CONTENTS (outdoor unit) 1. Make a TEST RUN in accordance with the in- stallation instruction sheet for the indoor unit. 2. OUTDOOR UNIT LEDS Error contents Communication error (Indoor unit - Out.
692 544 710 469 468 858 487 71 71 858 61 240 93 545 481 481 481 544 705 847 542 705 847 692 690 692 847 543 543 544 544 122 543 122 847 692 690 692 847 543 847 122 690 847 692 226 338 522 122 122 834-2 876-2 472-4 253-A 472-2 481-1 472-3 777-2 777-1 472-1 472-5 472-5 472-5 472-5 DISASSEMBLY ILLUSTRATION INDOOR UNIT 2006.
479 467 127 835 482 798 835 484 465 244 563 814 484 484 464 462 164 484 168 474 477 223 457 488 160 457 514 803 187 460-1 834-1 476-2 460-2 197 197 565 337-1 146-2 146-1 337-1 337-2 INDOOR UNIT 541 334 541-1 815-1 2006.
INDOOR UNIT 236 380 380 380 195 625 234 212 875 34 32 815-2 320-1 320-1 381-4 731-2 381-4 2006.05.18 15.
INDOOR UNIT 138 735 184-1 235 896 2006.05.18 16 187.
OUTDOOR UNIT 1 6 3 4 5 2 2006.05.25 17.
17 18 10 13 11 9 15 14 8 OUTDOOR UNIT 2006.05.25 18.
22 23 31 20 29 12 28 12 19 24 26 27 25 30 OUTDOOR UNIT 2006.05.24 19.
37 38 33 34 36 35 OUTDOOR UNIT 2006.05.18 20.
PARTS LIST INDOOR UNIT Ref. Part No. Ord. Ref. Part No. Ord. No MC24Y3F Q'ty No MC24Y3F Q'ty 32 Control Box Assy 67200589 472-3 RFM (Grille)-C 67200562 34 Capacitor (Fan Motor) 67220259 472-.
OUTDOOR UNIT Ref. Part No. Ord. No MR24UY3F Q'ty 1 Top Panel Sub Assy 67201640 2 Front Panel 67201601 3 Fan Guard 67201602 4 Grip Side 67201603 5 Service Panel Sub Assy 67201688 6 Right Panel 672.
INDOOR UNIT ACCESSORIES OUTDOOR UNIT ACCESSORIES Q’ty 2 2 4 4 1 1 2 2 1 1 Name and Shape Coupler heat insulation Tapping Screw (flush heads) Special nut A (large flange) Special nut B (small flange).
0605G3089.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Friedrich MR24UY3F è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Friedrich MR24UY3F - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Friedrich MR24UY3F imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Friedrich MR24UY3F ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Friedrich MR24UY3F, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Friedrich MR24UY3F.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Friedrich MR24UY3F. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Friedrich MR24UY3F insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.