Room Air Conditioner Ser vice and P ar ts Man ual CP10 CP12 SVC PARTS 2008 (07/08) C P 10 E 1 0 C P 1 2 E 1 0 0 F Power Mode Timer 0n/ 0 ff Fan Speed Temp Cool Money Saver ® Fan Only Dry hr Auto Swin.
2 Room Air Conditioner Air Conditioner Ser vice Manual T ABLE OF CONTENTS Safety Precautions ..........................................................................................................................................3 Dimensions .......
Ser vice Manual 3 Saf ety Precautions Safety Precautions T o pre v ent injury to the user or other people and proper ty damage, the f ollo wing instructions must be f ollo w ed. Incorrect ope r ation due to igno r ing inst r uctions will cause ha r m or damag e .
4 Room Air Conditioner Saf ety Precautions Plug in the power plug properl y . • Otherwise , it will cause elect r ic sho c k or fire. Do not operate or stop the unit b y inserting or pulling out the power plug. • It will cause electric shock or fire.
Ser vice Manual 5 Saf ety Precautions CAUTION • • • • • If water enters the pr oduct, turn off the the power s witch of the main bod y of appliance. Contact service center after taking the power - plug out from the soc ket. • It will cause electric shock or f ailure of machine.
6 Room Air Conditioner Dimensions Dimensions Outside Dimensions This symbol alerts you to the risk of electric shoc k. This symbol alerts you to hazar ds that could cause harm to the air conditioner .
Se r vice Ma n ual Specfications Pr oduct Specifications Ser 7 Pr oduct Specifications Ser Pr oduct Specifications Pr oduct Specifications POWER SUPPLY COOLING CAPACITY (Btu/h) INPUT (W) RUNNING CURRENT (A) E.
Operation Location and Function of Contr ols • DESIGNED FOR COOLING ONLY • POWERFUL AND INCREDIBLE COOLING • TOP-DOWN CHASSIS FOR THE SIMPLE INSTALLATION AND SERVICE • BUILT-IN ADJUSTABLE THER.
A i r P u r i f ie r P o w e r T e m p Mo d e T i m e r A S wi n g F a n S pe e d 1 2 4 3 5 0 F Power Mode Timer 0 n / 0 ff Fan Speed T emp Cool Money Saver ® Fan Only Dry hr Auto Swing 1 2 3 4 5 7 Auto Swing 6 6 6. A UTO SWING This button can automatically control the air flow direction (left+right) .
Disassembly Disassem b l y Mechanical Parts — Before the following disassembly, POWER SWITCH set to OFF and disconnect the power cord. 1. F R ONT GRILLE 1. Open the lnlet grille upward or downward. 2. Remove the screw which fastens the front grille.
1 1 Room Air Conditioner Disassembly Air Handling P ar ts —7— 1. AIR GUIDE AND BL O WER 1. Remove the front grille. 2. Remove the cabinet. 3. Remove the control box. 4. Remove the 3 screws which fasten the brace. 5. Remove the brace. 6. Remove the 2 screws which fasten the evaporator.
Se r vice Ma n ual 1 2 Electrical P ar ts 1. Remove the cabinet. 2. Remove the evaporator. 3. Remove the orifice. 4. Remove the blower. 5. Remove the fan. 6. Remove the control box cover and housing of the motor in the control box. 7. Remove the 2 screws which fasten the motor from the mount motor.
Se r vice Ma n ual 13 Disassembly 7. PO WER CORD Refrigerating Cycle CA UTION: Discharge the refrigerant system using a Freon TM Recovery System. If there is no valve to attach the recovery system, install one (such as a WATCO A-1) before venting the Freon TM .
1 4 Room Air Conditioner Disassembly — Replacement of the refrigeration cycle. 1. When replacing the refrigeration cycle, be sure to Discharge the refrigerant system using a Freon TM recovery System. If there is no valve to attach the recovery system, install one (such as a WATCO A-1) before venting the Freon TM .
Se r vice Ma n ual 15 Disassembly Equipment needed: Vacuum pump, Charging cylinder, Manifold gauge, Brazing equipment. Pin-off tool capable of making a vapor-proof seal, Leak detector, Tubing cutter, Hand Tools to remove components, Service valve.
16 Room Air Conditioner Schematic Dia gram Schematic Diagr am Cir cuit Diagram MODEL : TOUCH & REMOTE CONTROL TYPE MODEL LOCATION NO. 1 2 3 4 5 6 7 8 Q'TY PER SET 1 1 1 1 1 1 1 1 DESCRIPTION POWER CORD ASSEMBLY FAN MOTOR COMPRESSOR DISPLAY P.
17 Room Air Conditioner Electr onic Control De vice Schematic Diagram.
Se r vice Ma n ual 18 Components Location(For Main P .W .B ASM) Schematic Diagr am.
19 Room Air Conditioner T roubleshooting Guide T r oubleshooting Guide Piping System Figure 38 is a brief description of the important components and their function in what is called the refrigeration system. This will help you to understand the refrigeration cycle and the flow of the refrigerant in the cooling cycle.
Se r vice Ma n ual 2 0 T roubleshooting Guide T roub leshooting Guide In general, possible trouble is classified in two kinds. The one is called Starting Failure which is caused from an electrical defect, and the other is ineffective Air Conditioning caused by a defect in the refrigeration circuit and improper application.
2 1 Room Air Conditioner T roubleshooting Guide Fails to Start Improper thermistor setting Loose terminal connection Improper wiring Check of power source. Drop of power voltage. Capacitor check. Replacement. Check of control panel setting. Compressor fails only to start.
Se r vice Ma n ual 22 T roubleshooting Guide ■ MODEL : BG8000ER, WG8000RY4, WG1000RY4 ELECTRIC P AR TS TROUBLESHOO TING GUIDE: P ossible T rouble 1 • The unit does not operate. Is the Trans input power AC 115V? Is the Trans output power about AC 14V? Is shorted the Trans.
23 Room Air Conditioner T roubleshooting Guide Is Temp. setting set lower than Room Temp.-0.5 ° C? Is the voltage No.10 of IC01M 0V? • Exchange IC01M. • Set the Temp. setting to lower Temp. • Wait 3 Minutes Is the Unit for 3 minutes delay? • Exchange MAIN P.
Se r vice Ma n ual 24 T roubleshooting Guide Is the voltage of Battery about over 2.3V? • Exchange Receiver Ass'y. Is the connection of CN-DISP1 all right? Is the voltage No.16 of CN-DISP1 on Main P.W.B Ass'y DC 5V? • Exchange the battery.
25 Room Air Conditioner T roubleshooting Guide ROOM AIR CONDITIONER VOLTAGE LIMITS NAME PLATE RATING MINIMUM MAXIMUM 115V ± 10% 103.5V 126.5V COMPLAINT CAUSE REMEDY Fan motor will not run. No power Check voltage at outlet. Correct if none. Power supply cord Check voltage to rotary switch.
Se r vice Ma n ual 26 T roubleshooting Guide COMPLAINT CAUSE REMEDY Fan motor noise. Fan If cracked, out of balance, or partially missing, replace it. Blower If cracked, out of balance, or partially missing, replace it. Loose set screw Tighten it. Worn bearings If knocking sounds continue when running or loose, replace the motor.
27 Room Air Conditioner COMPLAINT CAUSE REMEDY Compressor cycles on Voltage Check the voltage. See the limits on the overload. preceding page. If voltage is not within these limits, call an electrician. Overload Check overload, if externally mounted. Replace if open.
Se r vice Ma n ua l 28 Exploded Vie w Exploded Vie w 249950 238310 237200 554030 359011 552113 552102 35211A 352113 135500 W0CZZ 567480 264100 W5210E-2 W5210E-1 268711-1 268711-2 146812 731273 267110 .
29 Room Air Conditioner R e p l a c e m e n t P a r t s l i s t LocNo CP10E10 CP12E 10 DESCRIPTION REMA RK 130410 67302929 67302929 Base As sy Single R 349001 67303508 67303508 Damper A ssemb ly R 130.
CP10 CP12 SVC P ARTS 2008(07/08) Post Office Box 1540 • 4200 N. Pan Am Expressway • San Antonio, Texas 78295-1540 • (210) 357-4400 • FAX (210) 357-4490 FRIEDRICH AIR CONDITIONING CO. Visit our web site at www.friedrich.com Use F actor y Cer tified P ar ts.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Friedrich CP12E10 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Friedrich CP12E10 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Friedrich CP12E10 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Friedrich CP12E10 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Friedrich CP12E10, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Friedrich CP12E10.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Friedrich CP12E10. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Friedrich CP12E10 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.