Room Air Conditioner Ser vice and P ar ts Man ual C P05 .Svc (0 5 /0 6 ) CP05C10.
—2— CONTENTS 1. PREF A CE ...................................................................................................................................................3 1.1 FEA TURES...........................................................
1. PREF A CE This ser vice manual provides v ar ious ser vice inf or mation, including the mechanical and electrical par ts, etc. This room air conditioner was manuf actured and assembled under a strict quality control system. The refrigerant is charged at the factory .
—4— 1.3 LOCA TIONS OF CONTR OLS 1 2 3 4 6 5 MONEY SAVER 2 The fan stops when the compressor stops cooling. • Approximately every 3 minutes the fan will turn on and sample the room air to determine if more cooling is needed. TEMPERATURE SETTING 1 • These buttons control the temperature of the room.
— 5 — 2. DISASSEMBL Y INSTR UCTIONS 2.1 MECHANICAL P AR TS 2.1.1 FRONT GRILLE 1. Pull the inlet grille forw ard. 2. Remov e the screw securing the F ront Gr ille. (Fig. 3) 3. Push the grille up from the bottom and pull the top of the grille aw ay from the case to lift the top tabs out of their slots.
— 6 — 2.2 AIR HANDLING P AR TS 2.2.1 AIR GUIDE UPPER 1. Disconnect the unit from the pow er source . 2. Remov e the front grille. (Ref er to Section 2.1.1) 3. Remov e the cabinet. (Refer to Section 2.1.2) 4. Rem o v e the control panel. (Ref er to Section 2.
— 7 — 2.2.3 MO T OR 1. Disconnect the unit from the pow er source . 2. Remov e the front grille. (Ref er to Section 2.1.1) 3. Remov e the cabinet. (Refer to Section 2.1.2) 4. Rem o v e the control panel. (Ref er to Section 2.1.3) 5. Rem o v e the uppe r air guide .
— 8 — 2.3.2 COMPRESSOR 1. Remov e the front grille and cabinet. (Ref er to Section 2.1) 2. Discharge the refrigerant by using a refrigerant recov er y system. 3. Remov e the ov erload protector . (Ref er to Section 2.3.1) 4. After discharging the unit completely , unbrace the suction and discharge pipes at the compressor connections.
— 9 — 2.3.6 PO WER CORD 1. Disconnect the unit from source of power . 2. Remov e the front grille. (Ref er to Section 2.1.1) 3. Remov e the cabinet. (Refer to Section 2.1.2) 4. Rem o v e a scr e w that secures control panel to base pan. (Ref er to Section 2.
2.4.2 EV APORA T OR 1. Remov e the cabinet. 2. Discharge the refrigerant by using a refrigerant recov er y system. 3. Rem o v e the uppe r air guide . (Re f er to Section 2.2.1) 4. After discharging the refrigerant completely , unbraze the interconnecting tube at the condenser connections.
— 11 — Equipment needed: V acuum pump , charging cylinder , manifold gauge , brazing equipment, pinch-off tool capable of making a vapor proof seal, leak detector , tubing cutter , hand tools to remov e components and ser vice valv e.
— 12 — 2 . 4.4 ELECTRICAL D AT A USE OF EXTENSION CORDS Because of potential saf ety hazards, w e strongly discourage the use of an e xtension cord. Howe ver , if you wish to use an e xtension cord, use a CSA cer tified/UL-listed 3-wire (grounding) e xtension cord, rated 15A, 125V .
— 13 — 3 .2 PIPING SYSTEM F ollowing is a brief descr iption of the impor tant components and their function in what is called the refr igeration system. Ref erence should be made to Figure 32 to follow the refrigerating cycle and the flo w of the refr igerant in the cooling cycle.
— 14 — 3 .3 T R OUBLESHO O TING GUIDE In general, possib le trouble is classified in two kinds. The one is called Starting Failure which is caused b y an electrical defect. The other is Ineffective Air Con- ditioning caused by a def ect in the refrigeration circuit and improper application.
— 15 — Fails to Start Improper ther mostat setting Loose terminal connection Improper wiring Che c k voltage power source. Drop of power v oltage. Capacitor check. Replacement. Che c k control s witch setting. Compressor f ails to star t. De f ect of compressor or capacitor .
COMPLAINT CA USE REMED Y F an motor will not run. No power Check v oltage at outlet. Correct if none. P o w er supply cord Che c k v oltage to electronic control board. If non e , check p o w er supply cord. Replace cord if circuit is open. Wire disconnected or Connect wire.
— 17 — COMPLAINT CA USE REMED Y F an motor noise. F an blade If crac ked, out of balance , or par tially missing, replace it. Bl o w er wheel If c r a c k ed, out of balanc e , or pa r tially missing, replace it. Loose set screw Tighten it. W o r n bea r ings If kno c king sounds cont i n ue when r unning replace the moto r .
— 18 — COMPLAINT CA USE REMED Y Compressor cycles on F an motor If not r unning, deter mine the cause. Replace if ov er load. required. Condenser air flow Remov e the cabinet, inspect the inter ior surf ace restriction of the condenser . If restricted, clean carefully with a vacuum cleaner (do not damage fins) or brush.
— 19 — 4 . CIRCUIT DI A GRAM WH(BL) POWER INPUT BK(BR) (Ribbed) (Plain) GN/YL (GN) GN/YL(GN) THERMIST OR BK BK BL RD BL RD CN-TH1 YL YL OR(BR) OR(BR) OR SYNC M OTOR R Y -LO R Y -HI CN-WORK CN-SYNC CN-DISP DISPLA Y P .W.B ASM R Y -SYNC 250V/T2A (115V/T2A) TRANS FORMER ZNR 43 R Y -COMP MAIN P .
— 20 — 5 . EXPLODED VIEW 352390 130410 359012 W48602 354210 349480 352390-1 149980 559011 346811 554030 W48602 130910 550140 554160 567502 352115 552102 352111 352113 35211A 135313 135303 152302 1.
LocNo FRIEDRICH DESCRIPTION 130410 67302921 Base Assy Single 130910 67303709 Cabinet Assy Single 135312 67306003 Grille Assy Front 135313 67304200 Grille Assy Inlet 14758 1 67304600 Link 147582- 1 67304501 Louver Vertical 2 ea.
— 22 — MEMO.
— 23 — MEMO.
Post Office Box 1540 • 4200 N. Pan Am Expressway • San Antonio, Texas 78295-1540 • (210) 357-4400 • FAX (210) 357-4490 FRIEDRICH AIR CONDITIONING CO.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Friedrich CP05C10 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Friedrich CP05C10 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Friedrich CP05C10 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Friedrich CP05C10 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Friedrich CP05C10, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Friedrich CP05C10.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Friedrich CP05C10. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Friedrich CP05C10 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.