Ser vice Manual W allMaster ® Thru-the-W all WM-ServMan (04-09) Wa i t th r e e m i n u tes be for e r es t a rt in g Wa r m e r Coo l e r F an O n ly Low H e a t Me d H e a t Hi g h H eat Lo w C oo l M e d C oo l H i g h C oo l M O DE TE M P E R A T U R E 72 Models 2009 2008 M o n ey F a n T im e r O p e r a ti o n S e tH r .
FRIEDRICH AIR CONDITIONING CO . Post Ofce Box 1540 · San Antonio, T exas 78295-1540 4200 N. Pan Am Expressway · San Antonio, T exas 78218-5212 (210) 357-4400 · F AX (210) 357-4490 www .
T able Of Contents Important Safety Information ....................................................................................................................2-4 Introduction ......................................................................
IMPORT ANT SAFETY INFORMA TION The information contained in this manual is intended for use by a qualied service technician who is familiar with the safety procedures required for installation and repair , and who is equipped with the proper tools and test instruments required to service this product.
Do not spray or pour water on the return air grille, discharge air grille, evaporator coil, control panel, • and sleeve on the room side of the air conditioning unit while cleaning.
PROPERTY DAMAGE HAZARDS FIRE DAMAGE HAZARDS: Read the Installation/Operation Manual for this air conditioning unit prior to operating. • Use air conditioner on a single dedicated circuit within the specied amperage rating. • Connect to a properly grounded outlet only .
5 FRIEDRICH WALLMASTER MODE L NUMB ER CODE W S 08 B 1 0 B 1st DIGIT - FUNCTION W = Thru-The-W all, W allMaster Series 2nd DIGIT - TYPE S = Straight Cool E = Electric Heat Y = Heat Pump 3rd & 4th D.
6 20 08 / 20 0 9 PERFORMA NCE DA T A * Rati ng C on diti on s: 80 d egr ees F , room ai r tem p. & 50% r elat ive hu midi t y , wit h 95 d eg ree F , outsi de air t emp & 4 0% re lat ive hum i.
7 Wire Size Use O NL Y wir ing size rec ommende d for single out let branch c ircuit. F use/Circuit B reaker Use ON L Y the cor rec t HACR type and size fuse/circuit breaker . Read elec tr ical ratings on unit ’ s r ating plate. Proper circ uit protecti on is the re sponsibiit y of the h omeowne r .
F U N C TI O NA L CO MP O NE NT S A . Me c ha ni ca l c o m p onen ts Drain pan valve T em p er atur e- sensi tiv e v a lv e t hat o p ens u p to dr ain o ff co nden s a te w a ter wh en t he ou tsi d.
Ho w to o p e ra te t h e Fr iedric h W allMaster Figure 1: WS Model cool-only control panel Figure 2: WY/WE Model heat-cool control panel 1 Power 2 3 4 8 Cool Fan Smart 9 Fan Only 6 Mode Speed Fan He.
To s e t t h e t i m e r NOTE : Se t the HOUR C LO CK ( S et Hour ) before a tt emp ting to s et timer f uncti ons. Yo u ca n set the Star t Time and Stop T im e a m inimum o f one hour apa rt , and a m ax imu m of 23 h ou rs apa rt . 11 Af ter se tt ing the time , press the Set Hour b ut ton on ce ( Star t ligh t on ).
Fi gure 3 : WY /W E heat -c oo l mo del r em ot e con tr o l Additional R C1 w irele ss re mote c on trol s ca n be p ur cha sed f rom yo ur F ried ri ch d eale r. Fi gure 4 : WS M o de l s O n l y Additional R C1 w irele ss re mote c on trol s ca n be p ur cha sed f rom yo ur F ried ri ch d eale r.
ELECTR ONIC CONTROL P ANEL CHECKING ROOM TEMPERA TURE 1. C h ec k th e ro om te m pe r at u r e a t the el ec tr o ni c con t ro l pad by pressing at the same time, the F an S pe ed button and t he T emp /Hour b u tt o n o n the WS/ WE / W Y m odels (see gures 5 and 6) .
ERR OR CODES LISTING FOR “WS” MODELS E 1 SHOR T CY CLE S ITUA TI ON: De n e d as a co mp r es so r th a t st arts an d st o ps mor e fr eq u en t l y th a n i t s h ou l d . E2 K E YBOARD STUCK ERROR: If an y ke y bu tt on is st u ck or pr e ss ed fo r 20 se con d s or mor e , the u ni t con s id e rs it st u ck .
Figure 8: System Control Switch (Heat Pump & Electric Heat Models) Fan Only Off Low Cool Low Heat Med Cool Med Heat High Heat High Cool MAX HEAT MAX COOL ! Allow 3 min. between restarts SYSTEM CONTROL SWITCH - TEST Disconnect leads from control switch.
15 ELECTR ONIC CONTROL OPERA TION Heat Pump w/back up Electric Heat If t he in door ambient air themi ster re ads 5 5 degrees, turn of f t he co mpress or and tur n on the ele ctr ic heat and continu e fan operati on until temp s ettin g is satis ed.
16 CAP ACIT ORS ELECTRIC SHOCK HAZARD W ARNING T urn off electric power before servicing. Discharge capacitor with a 20,000 Ohm 2 W att resistor before handling. Failure to do so may result in personal injury , or death. Many motor capacitors are internally fused.
17 DRAIN P AN V AL VE During the cooling mode of operation, condensate which collects in the drain pan is picked up by the condenser fan blade and sprayed onto the condenser coil. This as - sists in cooling the refrigerant plus evaporating the water .
Suction Line Evaporator Coil Metering Device Refrigerant Strainer Discharge Line Condenser Coil Compressor Refrigerant Drier Liquid Line A good understanding of the basic operation of the refrigeration system is essential for the service technician.
R efrigerant Char ging NOTE: Because The W allMaster System Is A Sealed System, Service Process T ubes Will Have T o Be Installed. First Install A Line T ap And Remove Refrigerant From System. Make Necessary Sealed System Repairs And V acuum System. Crimp Process T ube Line And Solder End Shut.
3. Install a process tube to sealed system. 4. Make necessary repairs to system. 5. Evacuate system to 300 microns or less. 6. Weigh in refrigerant with the property quantity of R-22 refrigerant. 7. Start unit, and verify performance. 8. Crimp the process tube and solder the end shut.
Underchar ged R efriger ant Systems An undercharged system will result in poor performance (low pressures, etc.) in both the heating and cooling cycle. Whenever you service a unit with an undercharge of refrigerant, always suspect a leak. The leak must be repaired before charging the unit.
R estricted Refrigerant System T roubleshooting a restricted refrigerant system can be difcult. The following procedures are the more common problems and solutions to these problems. There are two types of refrigerant restrictions: Partial restrictions and complete restrictions.
METERING DEVICE Capillar y T ube Systems All units are equipped with capillary tube metering devices. Checking for restricted capillary tubes. 1. Connect pressure gauges to unit. 2. Start the unit in the cooling mode. If after a few minutes of operation the pressures are normal, the check valve and the cooling capillary are not restricted.
NOTE: System operating pressures must be near normal before valve can shift . REVERSING V AL VE DESCRIPTION/OPERA TION The Reversing V alve controls the direction of refrigerant ow to the indoor and outdoor coils. It consists of a pressure-operated, main valve and a pilot valve actuated by a solenoid plunger .
Reversing V alve in Heating Mode TESTING THE COIL The solenoid coil is an electromagnetic type coil mounted on the reversing valve and is energized during the operation of the compressor in the heating cycle. 1. T urn of f high voltage electrical power to unit.
8. Pressurize sealed system with a combination of R-22 and nitrogen and check for leaks, using a suitable leak detector . Recover refrigerant per EP A guidelines. 9. Once the sealed system is leak free, install solenoid coil on new valve and charge the sealed system by weighing in the proper amount and type of refrigerant as shown on rating plate.
Lock ed Rotor V olta ge (L.R.V .) T est Locked rotor voltage (L.R.V .) is the actual voltage available at the compressor under a stalled condition. Single Phase Connections Disconnect power from unit.
Single Phase Resistance T est Remove the leads from the compressor terminals and set the ohmmeter on the lowest scale (R x 1). T ouch the leads of the ohmmeter from terminals common to start (“C” to “S”). Next, touch the leads of the ohmmeter from terminals common to run (“C” to “R”).
R ecommended procedur e for compr essor replacement 1. Be certain to perform all necessary electrical and refrigeration tests to be sure the compressor is actually defective before replacing. 2. Recover all refrigerant from the system though the process tubes.
1. 2. 3. 4. 5. ELECTRIC SHOCK HAZARD W ARNING T urn off electric power before service or installation. Failure to do so may result in personal injury , or death. S e a l e d R e f r i ge r a ti o n Sy s te m c o n t a i n s r e f r i g e r an t and oil under high pressure.
R OUTINE MAINTENANCE AIR FIL TER Clean the unit air intake lter at least every 300 to 350 hours of operation. Clean the lters with a mild detergent in warm water and allow to dry thoroughly before reinstalling. Units are to be inspected and serviced by qualied service personnel only .
Return Air Grille Decorative Front WSC Sleeve AB123456C3567 MODEL# WS07A10B Airflow Rotate D ischarge G rille 1" Diam eter Pl ug 1” Diameter Plug SLEEVE / DRAIN Inspect the sleeve and drain system periodically (at least yearly or bi-yearly) and clean of all obstructions and debris.
33 COOLING ONL Y ROOM AIR CONDITIONERS: TR OUBLESHOO TING TIPS n o i t c A e s u a C e l b i s s o P m e l b o r P Compressor does not run Low voltage Check voltage at compressor . 1 15V & 230V units will operate at 10% voltage variance T -stat not set cold enough or inoperative Set t-stat to coldest position.
n o i t c A e s u a C e l b i s s o P m e l b o r P Unit does not run Fuse blown or circuit tripped Replace fuse, reset breaker . If repeats, check fuse or breaker size.
35 n o i t c A e s u a C e l b i s s o P m e l b o r P Compressor runs for short periods only . Cycles on overload Overload inoperative. Opens too soon Check operation of unit.
Problem Possible Cause Action W ater “spitting” into room Sublimation: When unconditioned saturated, outside air mixes with conditioned air , condensation forms on the cooler surfaces Ensure that foam gaskets are installed in between window panes & in between the unit & the sleeve.
37 Problem Possible Cause Action Room temperature uneven (Heating cycle) Heat anticipator (resistor) shorted (on applicable models) Disconnect power to unit. Remove resistor from t-stat bulb block. Plus in unit & allow to operate. Feel resistor for heat.
38 n o i t c A e s u a C e l b i s s o P m e l b o r P Unit cools when heat is called for Incorrect wiring Refer to applicable wiring diagram Defective solenoid coil Check for continuity of coil Reversing valve fails to shift Block condenser coil & switch unit to cooling.
DISCHARGE TUBE SUCTION TUBE to T ube to OUTSIDE from Compressor T ube to INSIDE Capillary T ube Capillary T ube Compressor RIGHT Pilot LEFT Pilot COIL COIL 14 NORMAL FUNCTION OF V AL VE V AL VE OPERA .
WALLMASTER WIRING DIA GRAM ELECTR ONIC CONTROL COOL ONL Y MODELS: WS08B10A-D,A-F WS10BIO A-D WS14B10A-D WS14B10A-E WS10B30A-D WS13B30B-E,B-F WS16B30A-D,A-E 40.
WALLMASTER WIRING DIA GRAM ELECTR ONIC CONTROL COOL WITH ELECTRIC HEA T MODELS: WE10B33C-A WE13B33C-A WE16B33C-A 41.
WALLMASTER WIRING DIA GRAM ELECTR ONIC CONTROL HEA T PUMP WITH ELECTRIC HEA T MODELS: WY10B33C-A WY13B33C-A 42.
43 WALLMASTER WIRING DIA GRAM ELECTR OMECHANICAL CONTROL COOL WITH ELECTRIC HEA T MODELS: WE10B33A-C WE13B33B-D,B-E WE16B33A-C ,A-D.
44 WALLMASTER WIRING DIA GRAM ELECTR OMECHANICAL CONTROL HEA T PUMP WITH ELECTRIC HEA T MODELS: WY10B33A-C ,A-D WY13B33A-C ,A-D.
DK / Drain Ki t In st alle d at the ba ck of the unit and allows for at tachme nt to pe rmanen t co ndensa te disp os al sy st em, if disp osal is ne ce ssar y or desi re d.
FIGURE 1 MINIMUM OF 24” REQUIRED FROM TOP OF UNIT TO CEILING. INSIDE W ALL MINIMUM OF 1” SP ACING REQUIRED ON ALL SIDES OF LINTELS WSC SLEEVE DRAIN EXTENSION THE UNIT .
FIGURE 2 BACK UNIT REST LEVEL FRONT UNIT REST RAISED LEDGE INST ALLA TION REQUIREMENTS: STEP 1 The “WSC” SLEEVE should be positioned so that the DRAIN EXTENSION extends a minimum of 9/16” beyond the OUTSIDE W ALL (See Figure 1). STEP 2 The “WSC” SLEEVE must extend a minimum of 7/8” beyond the INSIDE W ALL.
48 MECHANICAL HAZARD W ARNING Be careful with the sharp edges and corners. Wear protective clothing and gloves, etc. Failure to do so could result in serious injury .
49 FIGURE A AIR DISCHARGE PLENUM FIGURE B SIDE PROFILE OF W ALL SLEEVE RAISED LEDGE GASKET FRONT UNIT REST Remove the black rubber gasket from the air discharge plenum of the air conditioner (see fi g. A). Look inside the wall sleeve and check to see if a black rubber gasket is already in place along the bottom front (see fi g.
50 INST ALLA TION INSTRUCTIONS FOR INTERNAL DRAIN KIT (IDK) Apply Sealer to the bottom of the Drain Plate Drill a .625” diameter hole here Dimple W all Sleeve Sleeve Base 0.5” In from edge 4.75” From back of basepan Drill a .625” diameter hole in the bottom of the basepan 1.
51 51 MECHANICAL HAZARD W ARNING Be careful with the sharp edges and corners. Wear protective clothing and gloves, etc. Failure to do so could result in serious injury . CUT/SEVER HAZARD EXCESSIVE WEIGHT HAZARD W ARNING Use two people to lift or carry the unit, and wear proper protective clothing.
52 52 MECHANICAL HAZARD W ARNING Be careful with the sharp edges and corners. Wear protective clothing and gloves, etc. Failure to do so could result in serious injury .
53 53 MECHANICAL HAZARD W ARNING Be careful with the sharp edges and corners. Wear protective clothing and gloves, etc. Failure to do so could result in serious injury .
54 54 MECHANICAL HAZARD W ARNING Be careful with the sharp edges and corners. Wear protective clothing and gloves, etc. Failure to do so could result in serious injury .
55 Friedrich Air Conditioning Company P.O. Box 1540 San Antonio, TX 78295 210.357.4400 www .friedrich.com WALLMASTER ® THRU-THE-WALL AIR CONDITIONERS LIMITED WARRANTY FIRST YEAR A NY PART: If any par.
.
FRIEDRICH AIR CONDITIONING CO . Post Ofce Box 1540 · San Antonio, T exas 78295-1540 4200 N. Pan Am Expressway · San Antonio, T exas 78218-5212 (210) 357-4400 · F AX (210) 357-4490 www .
FRIEDRICH AIR CONDITIONING CO . Post Ofce Box 1540 · San Antonio, T exas 78295-1540 4200 N. Pan Am Expressway · San Antonio, T exas 78218-5212 (210) 357-4400 · F AX (210) 357-4490 www .
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Friedrich 2008 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Friedrich 2008 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Friedrich 2008 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Friedrich 2008 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Friedrich 2008, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Friedrich 2008.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Friedrich 2008. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Friedrich 2008 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.