Manuale d’uso / di manutenzione del prodotto 566 del fabbricante Fluke
Vai alla pagina of 30
® 566/568 Infrared Thermometers Users Manual August 2007 Rev. 2, 4/08 © 2007-2008 Fluke Corporation, All rights reserved. Product specifications ar e subject to change without notice. All product name s are trademarks of thei r respective co mpanies.
LIMITED WARRANTY A ND LIMITATION OF LIAB ILITY Each Fluke product is warranted to be free from defec ts in material and workmanship under norm al use and service. The warranty per iod is two years and begins on the date of shipment. Parts, product repairs, and services are warranted for 90 days.
i Table of Contents Title Page Introduction ........................................................................................................ 1 Contacting Fluke ...................................................................................
566/568 Users Manual ii Maintenance ....................................................................................................... 17 Battery Charge .............................................................................................
iii List of Tables Table Title Page 1. Symbols .................................................................................................................. 3 2. Top-Level Menu Description .........................................................
566/568 Users Manual iv.
v List of Figures Figure Title Page 1. Laser Safety Markings ........................................................................................... 3 2. Menu Navigation .............................................................................
566/568 Users Manual vi.
1 Infrared Thermometers Introduction The 566 and 568 Infrared Therm ometers (“the thermometers”) are for non- contact temperature measurement. These thermometers determine an object’ s surface temperature by measuring the amount of infrared energy radiated by the object’s surface.
566/568 Users Manual 2 Safety Information W Warning A Warning identifies conditions and actions that pose hazards to the user. To avoid personal injury, follow these guidelines: • * Do not point laser directly at eye or indirectly off reflective surfaces.
Infrared Thermometers Symbols and Markings 3 Symbols and Markings Table 1 and Figure 1 show various symbols and safety markings that are on the thermometers and in this manual. Table 1. Symbols Symbol Explanation X Hazardous voltage. Risk of electrical shock.
566/568 Users Manual 4 Features The thermometers include: • Single-spot laser sighting • Infrared and thermocouple temperature display • 12 or 24 hour clock • Celsius or Fahrenheit temperature.
Infrared Thermometers Menu Overview 5 Menu Overview There are many settings that can be easi ly changed by using the menu. Figure 2 shows the LCD and menu interface. Selecting the Menu softkey advances the menu to the next level. Table 2 is a top-level description of the menu.
566/568 Users Manual 6 The reading includes: • IR temperature • Thermocouple temperature (if connected) • Emissivity • Min/Max/Avg/Dif (if either Min/Max or Avg/Dif is enabled) • Date/Time You may also press the Cancel softkey to abort saving the reading.
Infrared Thermometers Menu Overview 7 • To enter an emissivity value manually: 1. Press the No . softkey. 2. Use the down or up arrow softkey to change the entry. Hold down the up or down arrow softkey to increase the rate of change. 3. Press the Done softkey when finished to return to the main menu.
566/568 Users Manual 8 2. Press the Avg softkey. The display shows the present reading, average reading, the differential reading between max and min (designated by Δ ), and the em issivity setting. Note Min, Max, Avg, and Differential readi ngs are saved as part of the saved data when either Min/Max or Avg/Dif mode is enabled.
Infrared Thermometers Menu Overview 9 Setup From the Setup menu, the backlight, time and da te, and display language can be changed. Backlight In normal use, the backlight is always on. Use this menu to change the backlight setting from on to off. Turning the backlight off conserves battery power.
566/568 Users Manual 10 10. Press the Next softkey to move through each parameter. 11. Press the Done softkey when finished. The display reverts to the beginning of the Time/Date menu. Language To change the displayed language: 1. From the main menu, press the Menu softkey until Setup appears as the left softkey function.
Infrared Thermometers How the Thermom eters Work 11 How the Thermometers Work Infrared thermometers measure the surface te mperatu re of an object. The thermometer’s optics sense emitted, reflected, and transmitte d energy, which is collected and focused onto a detector.
566/568 Users Manual 12 Locating a Hot or Cold Spot To find a hot or cold spot, aim the thermometer outside the desired area. Then, slowly scan across the area with an up and down motion until you locate the hot or cold spot (see Figure 4). eyl07.eps Figure 4.
Infrared Thermometers Operating the Thermometer 13 Distance and Spot Size As the distance (D) from the object being measured increases, the spot size (S) of the area measured by the unit becomes larger. The rela tionship between distance and spot size (D:S) for each unit is shown in Figure 5.
566/568 Users Manual 14 Field of View For accurate measurements, make sure that the target is larger than the unit’s spot size. The smaller the target, the closer you should be to it (see Figure 6). Ye s N o eyl05.eps Figure 6. Field of Vie w Emissivity Emissivity describes the energy-emitting characteristics of materials.
Infrared Thermometers Operating the Thermometer 15 Storing Data The 566 thermometer can store up to 20 data records. The 568 thermometer can store up to 99 data records.
566/568 Users Manual 16 External Contact Probe XW Warning To avoid electrical shock or personal injury, do not connect the external contact probe to live electrical circuits. The thermometers come with a bead K-type thermocouple probe. The probes attach to the thermometers via the probe input located on the top of the thermometer (see Figure 7).
Infrared Thermometers Maintenance 17 Maintenance Battery Charge Use the battery charge symbols to gauge th e approximate level of charge left on the batteries. Notes When in low battery mode, the therm ometer does not store values. “Err” appears on the display if attempted.
566/568 Users Manual 18 Cleaning the Lens Blow off loose particles using clean compr essed air. Carefully wipe the surface with a water-moistened cotton swab. Cleaning the Housing Use soap and water on a damp sponge or soft cloth. W Caution To avoid damaging the thermometers, do NOT submerge them in water.
Infrared Thermometers User Replaceable Parts and Acce ssories 19 Recommended Temperature Probes See Table 6 for a list of recommended temperature probes.
566/568 Users Manual 20 Specifications Feature 566 568 IR Temperature Range -40 ° C to 650 ° C (-40 ° F to 1200 ° F) -40 ° C to 800 ° C (-40 ° F to 1470 ° F) Accuracy <0 °C: ±(1.0 °C + 0.1 °/1 °C) >0 °C: ±1 % or ± 1.0 °C, whichever is greater (<32 F±2 °F ±0.
Infrared Thermometers Specifications 21 Feature 566 568 Battery Life 12 hours with laser and backlight on; 10 0 hours with laser and backlight off, at 100 % duty cycle (thermometer continuously on) CE.
566/568 Users Manual 22.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Fluke 566 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Fluke 566 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Fluke 566 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Fluke 566 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Fluke 566, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Fluke 566.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Fluke 566. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Fluke 566 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.