NuDOG-MPT User ’ s Manual V 1.0.0 August 29, 2007.
E-Mail: sales@xtramus.com Http://www . X tramus.com XTRAMUS TECHNOL OGI ES ® Xtramus T echnologies E-mail: sales@xtramus.com Web: http://www .xtramus.com Phone: +886-2-8227-66 1 1 Fax: +886-2-8227-6 622 Copyright Copyright © 2007 Xtramus T echnologies.
E-Mail: sales@xtramus.com Http://www . X tramus.com XTRAMUS TECHNOL OGI ES ® CONTENTS 1. Introduction ................................................................................................................ 1 1.1 Specifications ..............
1 E-Mail: sales@xtramus.com Http://www . X tramus.com XTRAMUS TECHNOL OGI ES ® 1. Introduction NuDOG-MPT makes NuDOG an accurate and ef ficient Ethernet tester for batch tasks. V arious p acket generation and reception testing items could be set for pre-defined testing modules.
2 E-Mail: sales@xtramus.com Http://www . X tramus.com XTRAMUS TECHNOL OGI ES ® BC_100H BC_100F Filter T est FT_10H FT_10F FT_100H FT_100F CRC Error T est CRC_10H CRC_10F CRC_100H CRC_100F Ping T est Ping (A → B) Ping (B → A) Ping (A → N) Ping (B → N) 2.
3 E-Mail: sales@xtramus.com Http://www . X tramus.com XTRAMUS TECHNOL OGI ES ® Input user ’s information. Then click Next for next step. Confirm and review installation settings. Click Inst all for next step. NuDOG-MPT Inst allation is in progress.
4 E-Mail: sales@xtramus.com Http://www . X tramus.com XTRAMUS TECHNOL OGI ES ® 3. Main Window The main window of the user interface is illustrated below.
5 E-Mail: sales@xtramus.com Http://www . X tramus.com XTRAMUS TECHNOL OGI ES ® The choices for the Help Menu are described in the t able below: Menu Choice Usage Read Me Open an introduction file about settings. About NuDOG-MPT Show information of NuDOG-MPT version.
6 E-Mail: sales@xtramus.com Http://www . X tramus.com XTRAMUS TECHNOL OGI ES ® Loads settings of the model corresponding to DUT . Reloads the same model if the parameters have been modified. Connects to NuDOG . S tarts testing. S tops testing. Exits the program.
7 E-Mail: sales@xtramus.com Http://www . X tramus.com XTRAMUS TECHNOL OGI ES ® 3.2.5 T ime Tim e table displays the clock (the current time), what time the test st arts and finishes, and the total time the test t akes.
8 E-Mail: sales@xtramus.com Http://www . X tramus.com XTRAMUS TECHNOL OGI ES ® 3.2.8 Counter Window This table shows det ailed transmit and receive counters and any error for Port A and Port B during every task.
9 E-Mail: sales@xtramus.com Http://www . X tramus.com XTRAMUS TECHNOL OGI ES ® test), Time Used (how much time totally used), and Remark states the t ask result in Pass , Fail or Stopped . 3.2.10 LED Panel LED panel on the lower right shows ev ery task result.
10 E-Mail: sales@xtramus.com Http://www . X tramus.com XTRAMUS TECHNOL OGI ES ® 4.1.1 Configuration Setup Configuration Setup includes two settings, Environment and T asks . Environment refers to the surroundings and conditions of the configuration settings while T asks refers to which t ask(s) selected to be tested.
11 E-Mail: sales@xtramus.com Http://www . X tramus.com XTRAMUS TECHNOL OGI ES ® 4.1.2.2 T ask Selected # The column of T ask Selected # shows what test s are chosen to be tested in order . Click the desired test and then click Up button or Down button to arrange the selected tasks in orde r .
12 E-Mail: sales@xtramus.com Http://www . X tramus.com XTRAMUS TECHNOL OGI ES ® In T ransmit tab, the main purpose is to edit frame settings to transmit. More det ails are elaborated below . There are two options for frame length: Random and Fixed. The bytes of frame length range from 60 to 1514 without CRC.
13 E-Mail: sales@xtramus.com Http://www . X tramus.com XTRAMUS TECHNOL OGI ES ® 4.1.2.4 Media T ype Change Media Type allows changing media type in Nway or in Force. Or simply select OFF to stay with the default. Assign duration in seconds to wait for media type being changed.
14 E-Mail: sales@xtramus.com Http://www . X tramus.com XTRAMUS TECHNOL OGI ES ® In LED Check Setting, check the box of Enable LED Check Reminder to activate the four default settings. A message window will pop up every time before test to inquire about LED indicators being accurate.
15 E-Mail: sales@xtramus.com Http://www . X tramus.com XTRAMUS TECHNOL OGI ES ® In Learning Setting , check the box of Enable Learning to set up Frame Count, Frame Gap and Tx Pkt T imeout for sending learning packets before task. Halt on Error determines whether the test should be carried on or stopped when an error occurs.
16 E-Mail: sales@xtramus.com Http://www . X tramus.com XTRAMUS TECHNOL OGI ES ® 4.1.3 T ask Ping When Ping task is selected, the lower half appears the settings for Ping. The connection directions are available from Port A to Port B, from Port B to Port A, or from Port A or B to a connected switch or a network device.
17 E-Mail: sales@xtramus.com Http://www . X tramus.com XTRAMUS TECHNOL OGI ES ® 4.1.4 Environment Setting Environment setting includes Log File Setting, Check Link W ait T ime and Check Result W ait T ime to apply to the configuration. Assign Prefix and Suffix in Log File Setting .
18 E-Mail: sales@xtramus.com Http://www . X tramus.com XTRAMUS TECHNOL OGI ES ® A window as below will p op up if Bar code is chosen in Suffix. Input the bar code of the DUT in blank and click OK to exit. Assign the number of seconds to wait before checking the link st atus.
19 E-Mail: sales@xtramus.com Http://www . X tramus.com XTRAMUS TECHNOL OGI ES ® File name config is usually set as default for a new file name. Remember to save the config file after renewing a model. 4.2 Load Model Load the model corresponding to DUT before test.
20 E-Mail: sales@xtramus.com Http://www . X tramus.com XTRAMUS TECHNOL OGI ES ® 4.3 Modify Model After loading a model, Click Setting on the top menu and choose Modify Model . Its main purpose is to bring out existing configuration files to ch oose and to modify previous frame settings.
21 E-Mail: sales@xtramus.com Http://www . X tramus.com XTRAMUS TECHNOL OGI ES ® In T ask Setting, there are T est Scenarios and T ask Selected #. 4.4 Modify Configuration When the test is finished, the result is saved in a log file. Click Show Current Log to read the log information in notepad.
22 E-Mail: sales@xtramus.com Http://www . X tramus.com XTRAMUS TECHNOL OGI ES ® Show Current Config is to open a notep ad for the current configuration file (*.
23 E-Mail: sales@xtramus.com Http://www . X tramus.com XTRAMUS TECHNOL OGI ES ® Click Show Current Folder to open the current folder , which saves log files in the same model. Click Open button to bring out the window for the list of *.log files. T ask result s are directly footnoted in file names.
24 E-Mail: sales@xtramus.com Http://www . X tramus.com XTRAMUS TECHNOL OGI ES ® However , if any of the tasks fails, then the window of FA I L will pop up.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Alloy Computer Products NuDOG-MPT è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Alloy Computer Products NuDOG-MPT - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Alloy Computer Products NuDOG-MPT imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Alloy Computer Products NuDOG-MPT ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Alloy Computer Products NuDOG-MPT, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Alloy Computer Products NuDOG-MPT.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Alloy Computer Products NuDOG-MPT. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Alloy Computer Products NuDOG-MPT insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.