Manuale d’uso / di manutenzione del prodotto UV-12C del fabbricante Field Controls
Vai alla pagina of 12
UV-AIRE™ AIR PURIFYING SYSTEM Mode l: UV-12C,18C,28C, 28,12HP,18HP,28HP,12H PC,18HPC,28HPC READ THESE INSTRUCTIONS CAREFULLY AND COMPLETE LY BEFORE PROCEEDING WITH THE INSTALLATION LEAVE THE INSTALLATION INSTRUCTIONS WITH THE OWNER/OPERATOR OF THE DEVICE AFTER OPENING THE CARTON, UNPACK AND INSPECT THE UNIT AND LAMP FOR DAMAGE.
Page 2 I. INDICATION FOR USE This product is not sold as a medical device and is not for the purpose of diagnosis of any disease or co ndition nor for use in the mitigation, treatment, or pr evention of any disease or condition. II. GENERAL INFORMATION There are different size units avail able, depending on t he squ are footage of your home.
Page 3 III. INSTALLATION 1. Locate a suitable location for the unit downstream from t he ‘A’ coil in the supply plenum or in the return plenum; preferably downstream from the air filter. For optimum “clea n ing” effect on the ‘A’ coil, mount the unit in the supply plenum as close as possible to the ‘A’ coil.
Page 4 2. Determine the type of duct you have. (For flex duct applications, refer to Figure 26 on page 11) I F YOU HAVE METAL DUCT : a. Apply supplied wet and stick mounting template to air d uct in either a vertical or horizontal position as shown in Figure 2.
Page 5 3. Remove base unit and cover from box. 4. Apply supplied “Duct Se al Kit” according to instructions included in kit. (See Figure 12) 5. Determine whether to use flat or angled bracket. (Refe r to “Bulb Mounting Bracket Selection” in Section VI for aid in this decision ) a.
Page 6 8. Insert lamp t hrough the hole until lam p cannot be inserted any further. (See Figure 16) 9. Swing the swivel bracket over the end of lamp. Hand-tighten the wing nut o n the stud. Be careful no to over tighten the wing nut. The po rcelain at the lamp base may crack when over tightened.
Page 7 13. Close the cover and tighten co ver screw. (See Figure 21) 14. Plug the power cord into a standard electrical outlet. NOTE: Seal the joints an d seams of the plenum near the mounting location to reduce any direct viewing of light. (See Figure 1) 15.
Page 8 V. ALARM CIRCUIT WIRING The UV Aire units supplied with a circuit board allo ws for the wi ring of the UV Aire unit into an alarm or security system to monitor the operation of the UV lamp. This circuit is a set of normal open conta cts that close if the operational time exceeds 90 00 hrs or if th e lamp burns out.
Page 9 Chart A VI. BULB MOUNTING BRACKET SELECTION The UV-AIRE TM units come with an a ngled mounting bracket and flat mount ing bracket to position the bul b either straight or at an angle. Cho ose one or the other br acket method be st suited for your needs.
Page 10 VII. MAINTENANCE 1. Inspect and clean lamp at least every 6 months. 2. Replace your UV-Aire™ Ai r Purifying System lamp once a year to maintain the lamps maximum output intensity. The lamp should operate continuously fo r maximum lamp life and light effectiveness.
Page 11 IX. TROUBLESHOOTING GUIDE 1. If the LED is illuminating a “YELLOW” color a nd the ci rcuit board alarm beeps every 15 minutes, the lamp shoul d be replaced soon. 2. If the LED is illuminating a “RED” col or and the circui t board ala rm beeps every 5 minutes, the lamp sho uld be replaced immediately.
Page 12 WARRANTY INFORMATION The health aspects associa ted with the use of these products and t heir ability to aid in di sinfecting of environmental air have not been investigated b y UL. P/N 46453400 Rev E 10/05 Limited Warranty Field Controls, L.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Field Controls UV-12C è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Field Controls UV-12C - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Field Controls UV-12C imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Field Controls UV-12C ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Field Controls UV-12C, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Field Controls UV-12C.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Field Controls UV-12C. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Field Controls UV-12C insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.