O I L V E N T I N G G U I D E www .fieldcontrols.com May 2008 V enting for Oil Applications I N S I D E : The Evolution of V enting P ower V enters Sizing & Installation Specs Control Kits & S.
3 The PV O P ower V enter The ind oor mo unted P VO P ower V ente r provi des an econ omical pow er vent ing sys tem for oil appli ances. All c ontro ls are built i nto these un its.
4 As long as people have used fire to heat, it has been necessary to vent the smoke and combustion gases from the dwelling. Since heat rises, the natu ral solution was to allow the gases to vent through the roof via a hole or chimney .
P ower V enting In the early 1980's, F ield Controls introduced the PVO power venter . It was an indoor mounted power venter connected to the outside wall via a vent hood. The PVE, PVO and PVG series venters are still popular and in use today . In 1988, F ield introduced and patented the outdoor mounted SWG power venter .
6 ComboV ent ™ Combustion Air. P ower V enting . Combined. Introducing the most versatile, easiest to install, easiest to service, all inclusive combustion air/vent system ever made.
7 B A C D F E NOTE: Control Kits are required for operation of the SWG. “s” Designate s stainless steel model (recommended for oil applications). SWG Stainles s P ower V enter • 100% negative pressure in the vent pipe for maximum safety . • Standard galvanized pipe can be used instead of expensive stainless steel.
8 * Select venter according to the actual rated maximum GPH input. ComboV ent GPH ratings at 100 psi. Do not exceed maximum oil GPH input. F or multiple venting system applications add the input for each. Unit sizing may vary depending on specific application.
9 Locating The Power V ent er P r oc ed ur e 1 . De te rm in e th e to ta l eq ui va le nt f ee t fo r ea ch t yp e of f it ti ng u se d in t he v en ti ng s ys te m fr om T ab le 2 . 2 . Ca lc ul at e th e to ta l fe et f or t he s tr ai gh t le ng th s of p ip e.
T able 3 10 Clearance to Combus tibles If mounting the venting system near combustible materials, refer to Diagram A for allowable installation clearances.
11 Control Kits Model Applications CK-61 All oil-fired systems. Has adjustable electronic post purge. ✓ ✓ ✓ ✓ CK-62 All oil-fired systems. Has thermally activated post purge. ✓✓✓ ✓ CK-63 All oil-fired systems. (May require optional delay oil valve for simultaneous burner operation.
12 System Setu p Procedure for adjusting the pressu re switch • T urn pres sure switch adjustment clockwise until the burner quits. • T urn counter - clockwise slowly until the burner starts. • T urn an additional 1/4 to 1/2 turn counter - clockwise.
13 6. O nce pr ope r draf t is ac hi eved , mea su re CO2 a nd sm oke le vel . If n eces sar y , ad ju st the i nta ke a irfl ow at t he b ur ner to o btai n the h ig he st pos sib le C O2 rea din g with a z ero s moke r ead in g. A s th e in take a irf lo w is inc rea se d or de crea sed , th e draf t may c ha ng e.
14 Field Direct ™ V enting System Benefits of Field Direct V enting System • No a dver se re acti ons t o di rect w ind l oa ds u p to 5 0mph . • Bu rner e ffi cien cy ac tu al ly i mp ro ves un der d ir ect wi nd loa d. • De crea sed c hanc e of ex ha us t gase s rec ircu lat ing in to the s tru ctur e.
©2008 Field Controls form# 4318 Printed in U .S.A.(CP08) Field Controls, LLC | www .fieldcontrols.com | 263 0 Ai r po r t Roa d | K in s to n, N C 2 85 0 4 | TE L : 2 52 .
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Field Controls Oil Venting Systems è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Field Controls Oil Venting Systems - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Field Controls Oil Venting Systems imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Field Controls Oil Venting Systems ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Field Controls Oil Venting Systems, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Field Controls Oil Venting Systems.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Field Controls Oil Venting Systems. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Field Controls Oil Venting Systems insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.