Serial Bus for Navy Gateway GW0016 • Visual/Audible Alert messages • Easy Installation • W aterproof Connections • Easy to read Digital displays • Multiple Interfaces IS0210 rev .
Table of Contents Quick Reference page 2 turn system on/off page 2 turn on instrument lighting page 2 change lighting intensity page 2 disable audible alarm in Normal Mode page 2 change LCD display pa.
Navy Gateway (GW0016) System Manual The system consists of: • One Gateway box to interface with engine and external senders and sensors. • One 4” Tachometer with Fuel Monitor • Various 2” in.
Gateway System Specifications: Operation voltage: +12 V DC or +24 V DC +12 V DC (10 V DC (Min.) to 16 V DC (max.)) +24 V DC (20 V DC (Min.) to 32 V DC (max.
Several alarm conditions may also be displayed in the LCD display when needed: 1 Low fuel 2 Low oil pressure 3 Low voltage Alarm messages will be displayed on the tachometer LCD display.
b) Imperial gallons. Display will show c) Liters. Display will show Leaving the display in one of the items above while the “Mode” button is pressed and held for more than one second will save the selected units. Trip Fuel Consumed Displays fuel consumed since last reset.
Holding the “Mode” button for more than one second while the display is showing “ADJXXX.X” will set the amount in the display “XXX.X” into the Trip Fuel Consumed and return to the Trip Fuel Consumed function.
When the “Fuel Remaining” reaches this amount, the “Low Fuel” alarm will sound and a warning LED will flash in the display. The display will automatically go into “set” mode to allow the operator to reset the alarm value to a lower value to turn off the alarm if desired.
LCD Alarm Condition Displays. Alarm messages will be displayed on the Tachometer LCD display. All messages will be displayed until the problem is corrected, or the operator cancels the warning message. Severe co nditions includes a flashing red light.
Page 9 Faria ® Serial Bus Installation and Wiring Guide The system consists of: • One Gateway box to interface with the engine and external senders and sensors.
Page 10 T able1 Connector Contacts Pin Pin Function Wir e Color *5 amp Fuse Recommended P1 2 Not used P2 4 1 Battery Positive (always on)* Red 2 Ground 3 Switched Power from Ignition Purple switch cir.
Page 11 Faria Serial Bus Gateway T ypical Power Connections T ypical Instrument Connections P15 P13 P14 P12 P1 1 P7 P8 P10 P6 P5 P4 P1 P3 P15 P13 P14 P12 P1 1 P7 P8 P10 P6 P5 P4 P1 P3 P2 Note: T o help reduce moisture in the gauges be sure to install plug PJ0018 in all open connectors.
Page 12 P15 P13 P12 P7 P8 P10 P6 P5 P4 P1 P3 P2 White White Dk. Blue Nav . Light Switch Instrument Backlight Control P 1 1 6 5 4 3 2 1 7 8 9 10 1 1 12 P 12 6 5 4 3 2 1 7 8 9 10 1 1 12 Faria Serial Bus Gateway Miscellaneous Connections Pink Lt. Blue Oil Pressur e Sender Fuel T a nk Sender P 14 1 2 3 6 5 4 T rans.
Copyright 2004 by the Thomas G. Faria Corporation, Uncasville CT No part of this publication may be reproduced in any form, in an electronic retrieval system or otherwise, without the prior written permission of the company . Faria ® is the trademark of the Thomas G.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Faria Instruments GW0016 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Faria Instruments GW0016 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Faria Instruments GW0016 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Faria Instruments GW0016 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Faria Instruments GW0016, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Faria Instruments GW0016.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Faria Instruments GW0016. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Faria Instruments GW0016 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.