FALCON ® ELECTRIC, INC. SUP Series TM User’s Guide 700-1000VA WWW.FALCONUPS.COM 800.842.6940 SUP700-1C, SUP1.0K-1C FALCON® ELECTRIC, INC. 5106 Azusa Canyon Road Irwindale, CA 91706 Tel.
TABLE OF CONTENTS 1 Important Safety Instructions (READ FIRST) . . 2 Chapter 1. SUP UPS Overview . . . . 3 Chapter 2. Installation . ..... 4 Inspecting the Equipment .... 4 UPS Setup ....... 4 Communications Interface .... 5 Chapter 3. Controls, Displays & Functions .
IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS This manual contains important instructions which must be followed during the installation, operation and maintenance of this UPS and its batteries. Please read all instructions before operating this equipment and save this manual for future reference.
CHAPTER 1 CHAPTER 1 F ALCON ® SMP Series - Overview T he FALCON ® SUP Series UPS has the unique ability to operate from either 120Vac domestic or 230Vac international utility power, while providing 120Vac domestic output power.
CHAPTER 2 CHAPTER 2 Installation Inspecting the Equipment If any FALCON ® equipment has been damaged during shipment, keep the shipping cartons and packing materials for the carrier and file a claim for shipping damage. If you discover damage after acceptance, file a claim for concealed damage.
Communications Interface The UPS provides both a contact closure and a true RS-232 computer interface. The definition and setup for RS-232 is as follows: Baud Rate : 2400 bps Data Length : 8 bits Stop.
CHAPTER 3 CHAPTER 3 Controls, Displays & Functions A B C FRONT PANEL A. Main Control Button - This button is used to turn the UPS on and off, to perform a UPS self test, or to reset and silence an audible alarm. Refer to page 10 for operation instructions.
LCD SYMBOL DESCRIPTIONS 1. Over Load --The connected load exceeds the UPS output rating. Remove some of the load from the UPS to correct this condition.
6 Boost Mode - The AVR is increasing the UPS output voltage due to a low utility voltage condition or "Brown-out". The sinewave symbol is also displayed to indicate that the UPS is operating normally from the utility line.
15. LCD Metering Display - When the UPS is turned on, this portion of the LCD display indicates the AC output voltage initially. Depressing the downward scroll button will indicate the following each .
2. Input Fuse - Always replace with the same fuse type and rating. 3. Inlet - for connection of incoming power cord. 4. UPS output receptacles - The top NEMA type receptacles will be found on all domestic (120V) models. IEC type receptacles will be found on international (230V) models.
CHAPTER 4 CHAPTER 4 Operation 1. Turning The UPS On and Off Depending on how the UPS was turned off, it may automatically turn on when the input plug is plugged in. If it does not turn on automatically, depress the control button located on the front panel for four seconds until the UPS turns on.
6. Battery Charging This UPS is shipped from the factory with its batteries fully charged. However, some charge may be lost due to the self discharge characteristics of the internal sealed lead-acid battery. Always allow the UPS to recharge for 24 hours prior to use.
1. Care & Maintenance Falcon ® SUP Series UPSs are designed to be maintenance free. They can be cleaned with a damp cloth or non-abrasive cleanser, providing the UPS is turned off and the input plug is disconnected from the utility source.
The following precautions should be observed by a qualified technician when working with batteries: 1. Remove watches, rings, or other metal objects. 2. Use tools with insulated handles. 3. Wear rubber gloves and boots. 4. Do not lay tools or metal parts on top of batteries 4.
6. Technical Support Your FALCON ® Electric SUP Series UPS is backed by one of the finest customer service teams assembled. Write, call, fax or email should you require technical assistance or service. FALCON ELECTRIC, INC. 5106 Azusa Canyon Road Irwindale, CA.
1. TIME AND SCOPE OF WARRANTY: 1.1 FALCON ® hereby warrants parts shipped under this Agreement to be free from defective workmanship for a period of one year following date of shipment. Accidental damage, misuse or normal wear and tear shall not be construed as a defect.
SUP Series™ UPS 700VA & 1kVA Model Number SUP700 - 1C SUP1.0K - 1C Nominal VA 700 1000 Electrical Input Nominal AC Voltage 120V or 230V 120V or 230V Current - Amps 7 (120V), 3.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Falcon SUP1.0K-1C è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Falcon SUP1.0K-1C - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Falcon SUP1.0K-1C imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Falcon SUP1.0K-1C ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Falcon SUP1.0K-1C, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Falcon SUP1.0K-1C.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Falcon SUP1.0K-1C. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Falcon SUP1.0K-1C insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.