Simply connecting the world Patch Release Note Patch 86222-10 For Rapier Switches and AR800 Series Modular Switching Routers Intr oduction This patch rel ease note lists the issues addres sed and enhancements made in patch 86222-10 for Software Release 2.
2 Patch Release Note Patch 86222-10 for Software R elease 2.2.2 C613-10319 -00 REV J Some switch chip r egister settings have been optimised to impr ove the provision of CoS with the newer r evision of switching silicon. Featur es in 86222-09 Patch file details for Patch 86222-0 9 are listed in T able 2.
Patch 86222-10 For Rapier Switches a nd AR800 Series Modula r Sw itching Routers 3 Patch 86222-10 for Software R elease 2.2.2 C613-10319 -00 REV J A configuration pr oblem prevented trunk ing of gigabit ports at 100Mbit speeds. This issue has been resolved.
4 Patch Release Note Patch 86222-10 for Software R elease 2.2.2 C613-10319 -00 REV J The dot1dBridge MIB implementation now complies with RFC1493. Featur es in 86222-07 Patch file details for Patch 86.
Patch 86222-10 For Rapier Switches a nd AR800 Series Modula r Sw itching Routers 5 Patch 86222-10 for Software R elease 2.2.2 C613-10319 -00 REV J Debug messages ar e no longer generate d when a Q.931 Advise of Charge Notification message is re ceived.
6 Patch Release Note Patch 86222-10 for Software R elease 2.2.2 C613-10319 -00 REV J The T rigger Facility was generating a tr ap with variable { 0 0 }, and was not documented in the A TI enterprise MIB.
Patch 86222-10 For Rapier Switches a nd AR800 Series Modula r Sw itching Routers 7 Patch 86222-10 for Software R elease 2.2.2 C613-10319 -00 REV J A switch port that was transmitting STP B PDUs and also mirr oring its transmit traf fic to the mirror port caused a fatal err or .
8 Patch Release Note Patch 86222-10 for Software R elease 2.2.2 C613-10319 -00 REV J A39 copper uplink modules in the Rapier G6 sometimes experienced spurious link up or link down ev ents. This issue has been r e solved. The enterprise MIB now supports objects for power supply monitoring.
Patch 86222-10 For Rapier Switches a nd AR800 Series Modula r Sw itching Routers 9 Patch 86222-10 for Software R elease 2.2.2 C613-10319 -00 REV J When lar ge numbers of sessions were being handled the firewall would become overly aggr essive in r estricting new sessions.
10 Patch Release Note Patch 86222-10 for Software R elease 2.2.2 C613-10319 -00 REV J correctly when only one byte has been specified. The CRL update time is now displayed correctly in hours. If the username and password parameters ar e present the location parameter must be pr esent and appear before the username and password parameters.
Patch 86222-10 For Rapier Switches a nd AR 800 Series Modular Switching Routers 11 Patch 86222-10 for Software R elease 2.2.2 C613-10319 -00 REV J DNS response packets wi th corrupt length fields were causing a fat al error . This issue has been r esolved.
12 Patch Release Note Patch 86222-10 for Software R elease 2.2.2 C613-10319 -00 REV J The SHOW CPU command sometimes di splayed incorrect CPU util isation figures. T y pically a value of about 74% was reported when in fact the CPU was almost idle. Thi s issue has been r esolved.
Patch 86222-10 For Rapier Switches a nd AR 800 Series Modular Switching Routers 13 Patch 86222-10 for Software R elease 2.2.2 C613-10319 -00 REV J Repeated addition and deletion of an addr ess with the V ALID parameter set to or fr om an IPV6 interface caused a fatal err or .
14 Patch Release Note Patch 86222-10 for Software R elease 2.2.2 C613-10319 -00 REV J.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Allied Telesis 86222-10 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Allied Telesis 86222-10 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Allied Telesis 86222-10 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Allied Telesis 86222-10 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Allied Telesis 86222-10, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Allied Telesis 86222-10.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Allied Telesis 86222-10. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Allied Telesis 86222-10 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.