Manuale d’uso / di manutenzione del prodotto GX1050 del fabbricante Allied International
Vai alla pagina of 34
GX1050 / GX10 50C Allied Vision Technologies Canada Inc. 101-3750 North Fraser Way Burnaby, BC V5J 5E9 / Canada Technic al Man ual 700056 A April 7, 2010.
GX1050 T echnical Manu al Page 2 T able of Content s Table of Contents ............................................................................................................. 2 Introduction .......................................................
GX1050 T echnical Manu al Page 3 Legal notice For customers in the U.S.A. (FCC Complia nce Information) This equipment has been tested and f ound to comply with the limits for a Class A digital devic e, pursuant to Part 15 of the FCC Rules.
GX1050 T echnical Manu al Page 4 Contacting Allied Vision Technologies • Technical in formatio n: http://www. alliedvisiontec .com • Support: support@al liedvisiontec .com Allied Vision T echnolog ies GmbH (Headqua rters) Tasc henweg 2a 07646 Stadtr oda, Germ an y Tel.
GX1050 T echnical Manu al Page 5 Intr oduction The G X1050 series of cam eras are sen sitiv e, 1 12 f rames per s econd, 1 megap ixel, Gigabit E thernet cameras b ased on the Kodak K AI-01050 CCD sensor. The se cameras support the us e of 1 o r 2 gigabit E thernet ports in a LA G configuration for higher bandwidth requirem ents.
GX1050 T echnical Manu al Page 6 Canada Inc. will n ot warranty pa rts which have b een dama ged through the obvious misuse of this product..
GX1050 T echnical Manu al Page 7 Specification s Sensor Type Kodak KA I-01050 Sensor Shutte r Type Progressive Interline Image Re solution 1024 x 102 4 pixels Pixel Size 5.5 µ m x 5.5 µ m Optical Fo rmat 1/2 inch Lens Moun t C-mount with ad justable back focus.
GX1050 T echnical Manu al Page 8 Supported Features Imaging Mod es free-runnin g, external trigger, fixed rate, softwa re trigger Fixed Rate Co ntrol 0.
GX1050 T echnical Manu al Page 9 Mechanica l GX C-MOUNT.
GX1050 T echnical Manu al Page 10 Connections GX CONNECTIO N DIA GR AM.
GX1050 T echnical Manu al Page 11 GIGABIT ETHERNET P ORTS These ports confo rm to the IEEE 802.3 1000BA SE-T standard f or Gigabit Ethernet over copper. It is recommend ed that CAT5E o r CAT6 compatib le cabling and connectors be used for be st p erformance.
GX1050 T echnical Manu al Page 12 EXTERNAL POWER This connect ion p rovides the main p ower fo r the camera. T he camera opera tes f rom a DC voltage be tween 5V to 24V . Th e current capacity of t he power supply can be estimated by d ividing th e came ra ’ s po wer requiremen t by the external p ower volta ge.
GX1050 T echnical Manu al Page 13 SYNC OUTPUT S (1 to 4 ) These signals are o ptically iso lated a nd require the user to p rovide a high voltage level ( USER VCC ) and sig nal co mmon ( USER GROUND ). USE R VCC can b e from 5V to 24V. ICC is a func tion of USER VCC and load resistor R.
GX1050 T echnical Manu al Page 14 These signals only function as outputs a nd can be configured as f ollows: Exposing Correspon ds to when camera is integrating light.
GX1050 T echnical Manu al Page 15 LENS CONTROL P ORT PIN FUNCTION 1 IRIS + 2 IRIS - 3 FOCUS + 4 FOCUS - 5 ZOOM + 6 ZOOM - 7 AUTO IRIS SIGNAL 8 GROUND LENS CONTROL P ORT AS SEEN FROM BACK OF CAMER A This connector provides the s ignals necessary to control the iris, f ocus, and zoom of most commercially a vailable TV Zoom lenses.
GX1050 T echnical Manu al Page 16 Cleaning the Sensor DO NOT CONT A CT C LEAN SENSOR UNLES S ABSOLUTELY NECES SARY. Identifying Debris Debris on the image sensor or o ptical components will app ear as a darke ned area or smudge on the image t hat does not move as the camera is moved.
GX1050 T echnical Manu al Page 17 Adjusting the C-mount THE C-MOUNT IS A DJUS TED AT THE FACTORY AND SHOULD NOT REQUIRE AD JUSTIN G. If for some rea son, the C-mount require s adjustment, use the follo wing method. Loosen Lock ing Ring Use an adjustable wrench to loosen locking ring.
GX1050 T echnical Manu al Page 18 Network Card Configuration Operating G igE Vision GX cameras using multiple network adaptors The GX series cameras offer two Gigabit Etherne t ports for image data transfer and control. Users can c onnect one or both ports on the GX to Ethernet adap ter ports on a host computer.
GX1050 T echnical Manu al Page 19 5. Click on “ OK ” to validate your change (the “ Properties ” window will close). The Property list will be different between different types/brands of gigabit E thernet interface cards. If "Jum bo Frames" does not appear in this list , then your card pro bably does not support it.
GX1050 T echnical Manu al Page 20 adapter from others in your system. Click “ Next ” to co ntinue. 12. Se lect the two Ethernet po rts to which the GX camera will be con nected. These po rts w ill form our LAG or TEAM. Click “ Next ” to continue.
GX1050 T echnical Manu al Page 21 15. On ce completed the prop erties of the TEAM (LAG) that ha s just been created will appear. A new Network Connections Icon co rresponding to the LAG group is created. You have no w completed the Link A ggregate Group configuration.
GX1050 T echnical Manu al Page 22 GigE Sample Vie wer and Filter D r iver o Download GigE S ample Viewer from www .allied visiontec.com . This will install th e Sample V iewer application program, d rivers, and optionally the Prosilica Filter Driver. The Filte r Driver will improve CPU pe rformance and is recommended.
GX1050 T echnical Manu al Page 23 T rouble Shooting Is the came ra getting power? The Green LED is the camera pow er indicator. If unlit, check the power adapto r. If possible, swap with o ne that is known to work. If using a custom power ada ptor, be sure the adaptor su pports the voltage and power requirem ents of the camera .
GX1050 T echnical Manu al Page 24 The following example is not on the same Subnet : NIC IP 169.250. 23 .2 Sub net Mask: 255.255.255. 0, CamIP 169.2 54. 13.0 Subnet Mask: 255.255.0.0 . This can happe n if you use a non A utoIP range o n your NI C and it d oesn ’ t have access to a DHCP server.
GX1050 T echnical Manu al Page 25 All stats 0 while streaming. Fir ewall likely blocking traffic • All stats 0. Like ly a firewall is blocking incomin g traffic. Disable your f irewall. Check your camera trigger settin gs. Many camera trigger mo des require a software o r hardware trigger event to capture frames.
GX1050 T echnical Manu al Page 26 Addendum.
GX1050 T echnical Manu al Page 27 GX IO Schema tic PIN 3. SY N C OUT 4 VDD +3.3 TLP 281-4GB 7 8 10 9 PIN 9. RS -232 TX D CAMERA LOGIC SY N C OU T 2 CAMERA LOGIC SY N C OU T 3 1 2 3 4 5 6 7 8 9 10 11 12 HI R OSE H R 10A-10R-12PB TLP 281-4GB 5 6 12 11 100K C AM ERA LOGIC SY N C I N 2 4.
GX1050 T echnical Manu al Page 28 User T r igger Circuit Example This diagram indicates one exam ple of a 5V TTL based user t rigger circuit. 0.1u 10V CAMERA POWER USER LOGIC SY NC OU T 4 SY N C IN 2 .
GX1050 T echnical Manu al Page 29 TV Zoom Lens C onnection FO C U S+ Z OO M I RI S- FO C U S- C OM MO N FO C U S- FO C U S Z O O M- Z O O M+ C OM MO N Z OO M+ FO C U S Z O O M FO C U S+ C OM MO N H IR.
GX1050 T echnical Manu al Page 30 Video Ir is Connectio n V ID E O A UTO- IR IS L E NS H I R OSE 3240-8P-C(50) 1 2 3 4 5 6 7 8 LENS POWE R POW ER GR OU N D POW ER GR OU N D VI D EO SI GN AL 12V_POWER .
GX1050 T echnical Manu al Page 31 T rigger Timing Diagra m.
GX1050 T echnical Manu al Page 32 Notes on T riggering Definitions o User Trigger is the trigger signal applied by the user. o Logic Trigger is the trigger signal seen b y the camera internal logic. o Tpd is the p ropagation delay between the User Trigger and the Logic Trigger.
GX1050 T echnical Manu al Page 33 Triggering dur ing the Readout State o For applications requiring the faste st triggering cycle time whereb y the camera image sens or is exposing a nd readin g o ut sim ultaneously, the n the User T rigger signal shou ld be applied as soon a s a valid Trigger Ready is detect ed.
GX1050 T echnical Manu al Page 34 Camera Controls For the latest, up to date camera controls, see AVT Camera and Driver Attributes.pdf at http://ww w.alliedvisiontec.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Allied International GX1050 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Allied International GX1050 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Allied International GX1050 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Allied International GX1050 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Allied International GX1050, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Allied International GX1050.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Allied International GX1050. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Allied International GX1050 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.