Manuale d’uso / di manutenzione del prodotto 828 MH del fabbricante Enviro
Vai alla pagina of 25
SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONSIBLE COMPANY THIS MANUAL IS PRINTED ON RECYCLED PAPER 8 2 8 By SHERWOOD INDUSTRIES LTD. Direct Vent OWNERS MANUAL Installation And Operating Instructions For Models: 828 MH (MOBILE HOME) 828 DV. FS. (Freestanding) 828 DV.
SAFETY PRECAUTIONS FOR SAFE INSTALLATION AND OPERATION OF YOUR "ENVIROGAS" ROOM HEATER, PLEASE, CAREFULLY READ THE FOLLOWING INFORMATION: • All "ENVIROGAS" gas-fired appliances must be installed in accordance with these instructions.
TABLE OF CONTENTS 1 Code A pproval s ............................................................................................................. ..............................3 S pecificat ions .......................................................
2 . DIMENSIONS AND CLEARANCES TO COMBUSTIBLES FIREPLACE INSERT: The stove can only be installed in a so lid fuel burning fireplace . Mantle pillar to stove 10” Stove top to 8” wide mantle 12” Mi.
ZERO CLEARANCE BOX ASSEMBLY; First take the kit from the box and place the surround panels as ide so as not to damage the panels. There will also be a bag of screws, nuts and bolts in the box. The bottom section of the kit will have tw o 3 inch square boxes mounted to t he bottom.
3. DECIDING WHERE TO LOCATE YOUR STOVE FREESTANDING: • Locate the stove in a large and open room that is centrally located in the hous e. This will optimize heat circulation and comfort. • The stove should be located out of traffic, away from furniture and draperies and should have sufficient access for its safe operation and maintenance.
FIREPLACE INSERT • Carefully clean the fireplace and flue before in stalling the stove. Failure to do so ma y result in fumes or dirt being blown i nto the room or insert and may cause a fire leading to death or serious injury. • If you are installing the optional fan ki t, (see Installing Fan Kit) do so now .
5. INSTALLING BURNER CONTROL ASSEMBLY Remove the controls from box, che ck for shipping damage. Remove burner tray from controls (one scr ew on each side between burners). Open door. Remove grate rod by pu lling up at each end. Remove the 2 screws behind the grate and one screw on each side of control opening in firebox.
2. Place the log with Burnt Area forward on log supports. Locate the log by matching the bottom pegs to the receiving holes in rear log supports. 3. Close door securely 7. ELECTRICAL REQUIREMENTS T he ENVIROGAS 828 Series w ill operate wit hout an external electrical pow er supply.
8. GAS LINE CONNECTION AND TESTING WA RNING: Only persons licensed to w ork w ith gas piping can make the gas connections to this appliance. This appliance is equipped with a 3/8” stainless steel flex line from the valve. This line ma y be routed through the hole in the rear of the pedestal, or on inserts, routed through the fire box sides.
9. AIR SHUTTER ADJUSTMENT • There is a separate venturi air shutter for each burner • The venturies have been set for installation at sea level to 4,500 ft. • To adjust for higher altitudes : Remove the access cover plate, loosen the air shutter locking screws w ith a long screw driver.
10. VENTING VENT TERMINATION CLEARANCES A= Clearance above grade, ve randah, porch, deck, or [balcony (*12 inches (30cm) minimum] B= Clearance to window or door that may be opened [*12 inches (30cm) m.
These models have been tested and certified for use with SIMPSON DURAVENT DIRECT VENT TYPE "GS" PIPE FOR GAS STOVE. Kits are available for vertical venting or horizontal ve nting. It is recommended that a bead of RTV High Temperature Silicone be applied to each vent joint before installation.
When planning your installation, it w ill be necessary to select the proper length of vent pipe fo r y our particular requirements . It is important to note when passing thr ough a wall, the max imum allowable w all thickness is 10-inches (254mm), 1 ½ inches clearance to combustibles must be maintained.
STEP 7. Slide the decorative wall thimble up to the wall su rface and attach with the screws provided. Apply decorative brass or chrome trim if desired. FIG-14. FIG. 11 FIG. 12 FIG-13 FIG-14 NOTES: (1) The four wood screws provided should be replaced with th e appropriate fasteners for stucco, brick, concrete, or other types of siding.
VERTICAL INSTALLATION STEP 1. Check the instructions for required clearances (air spaces) to combustibles w hen passing through ceilings, walls, roofs, enclosures, attic rafters , or other nearby combustibl e surfaces. Do not pack air spaces w ith insulation.
NOTES: (1) If an offset is necessary in the attic to avoid obstruc tions, it is important to support the vent pipe every 3 feet, to avoid excessive stress on the elbows, and possible separation. Wall straps are available for this purpose. FIG- 18 (2) When ever possible, use 45 ° degree elbows instead of 90 ° degree elbows.
CATHEDRAL CEILING INSTALLATION Step 1. Follow installation steps 1 and 2 under Vertical Termination. Step 2. Using the plumb bob, mark the centerline of the venting system on the ceiling and drill a small hole through the ceiling and roof at this point.
11. MOBILE HOME FUEL CONVERSION To conve rt from Propane to Natural Gas or v ise-versa 1. Disconnect the unit from the gas supply. 2. Open the door and remove the logset. 3. Remove the burner tray (2 screw s) and the burner control assembly by removing the 8 screw s holding it into the unit.
12. OPERATING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE OPERATING WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIO NS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE , PERSONAL INJURY OR LOSS OF LIFE. A) This appliance is equipped with a pilot that must be lit by hand by following these instructions exactly.
13. MAINTENANCE AND TECHNICAL Periodically check to ensure that your "Direct Vent" sy stem is clear. Periodically check the pilot and burner. Check to see that all the burner ports are clean and clear. Check the pilot head for blockage. Check to ensure the pilot flame is blue wi th small yellow tips.
14. TROUBLE SHOOTING Problem Possible Cause Solution Spark will not light the pilot after repeated pressing of spark ignitor Defective piezo ignitor Check connections to ignitor -If ignitor connection.
15. PARTS AND ACCESSORIES Service Parts available from your local Envirogas Dealer. PA RT # DESCRIPTION 828-001 Convection Blower 828-002 Heyco Strain Relief 828-003 2-Speed Fan Switch 828-004 Eurosit.
16. WARRANTY Sherwood Industries Ltd. offers a *Lifetime Warranty on this gas product. The lifet ime warranty covers the appliance for a period of seven years from the date of installation.
17. INSTALLATION DATA SHEET The installer for warranty purposes and future re ference must record the following information. Envirogas Models: 828.DV. FS.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Enviro 828 MH è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Enviro 828 MH - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Enviro 828 MH imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Enviro 828 MH ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Enviro 828 MH, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Enviro 828 MH.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Enviro 828 MH. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Enviro 828 MH insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.