Manuale d’uso / di manutenzione del prodotto Diamond Distributed Forwarding Engine 7KR4297-02 del fabbricante Enterasys
Vai alla pagina of 64
8.5x11-inch cover with bleed on 4 sides Enterasys Matrix TM DFE-Diamond Series Hardware Installation Guide 7KR4297-02 7KR4297-04 P/N 9034365-01.
.
i Notice Enterasys Networks reserves the right to make changes in specifications and other information contained in this document and its web si te without prior notice.
ii Regulatory Compliance Information Federal Communications Commission (FCC) Notice This device complie s with Par t 15 of the FCC ru les.
iii Electromagnetic Compatibility (EMC) This product complies with the following: 47 CFR Par t s 2 and 15, CSA C108.8, 2004/108/EC, EN 55022, EN 61000 ‐ 3 ‐ 2, EN 61000 ‐ 3 ‐ 3, EN 55024, AS/NZS CISPR 22, VCCI V ‐ 3.
iv ѻ ѻ ક䇈ᯢк䰘ӊ Supplement to Product Instructions ᳝↦᳝ᆇ⠽䋼ܗ㋴ (Hazardous Substance) 䚼ӊৡ⿄ (Parts) 䪙 3E ∲ +J 䬝 &G ݁Ӌ䫀 .
v VCCI Notice This is a class A product based on the standard of the Vo l u n t a r y Contro l Council for Interfer ence by Information T echnology Equipment (VCCI).
vi Declaration of Conformity Application of Co uncil Directiv e(s): 2004/108/EC 2006/95/EC Manufacturer ’ s Name : Enterasys Networks, Inc. Manufacturer ’ s Address: 50 Minuteman Road Andover , MA 01810 USA European Representative Addre ss: Enterasys Networks, Ltd.
vii 2. RESTRICTIONS. Except as otherwise authorized in writing by Enterasys, You may not, nor may You permit any third party to:.
viii 7. LIMITATION OF LIABILITY. IN NO EVENT SHALL ENTERA SYS OR ITS SUPPLIERS BE LI ABLE FOR ANY DAMAGES WHATSOEVER (INCLUDING, WIT.
ix Contents About This Guide Who Should Use This G uide .............. ............. ................ ............. ................ ............. ................ ............. ........... xi How to Use This Guide ....................... ............
x Chapter 4: Troubleshooting Using LANVIEW ....... ................ ............. ................ ............. ............. ................ ............. ...... .......................... .. 4-1 Troubleshooting Checklist ............... ..........
Matrix DFE-Platinum Series Module Installation Guide xi About This Guide This guide provides an overview , installation and tr oubleshooting instructions, and s.
How to Use This Guide xii About This Guide How to Use This Guide This preface provides an overview of this guide and the DFE ‐ Diamond Series manual set, a brief summary of each chapter , and defines the conventions used in thi s document.
Document Conventions Matrix DFE-Platinum Series Module Installation Guide xiii Document Conventions The following typographical conventions and icons are used in this document.
Getting Help xiv About This Guide Getting Help For additional support related to the modules or this document, contact Enterasys Networks using one .
Matrix DFE-Platinum Series Module Installation Guide 1-1 1 Introduction This chapter provides an overview of the Matrix DFE ‐ Diamond 7KR4297 ‐ 02 and 7KR429 7 ‐ 04 modules and optional XFP 10 ‐ Gbps physical interface module.
The DFE-Diamond 7KR4297-02 and 7KR4297-04 Mod ules 1-2 Introduction The DFE-Diamond 7KR4297-02 and 7KR4297-04 Modules This section provides an overview of the 7KR4297 ‐ 0.
Management Matrix DFE-Platinum Series Module Installation Guide 1-3 Figure 1-2 7K R4297-04 D FE-Diamond M odule XFP 10GBASE-LR, -ER, -LX4, and -SR PHY S The LAN XFP PHY s (phy sical interfaces) provide inexpensive, high ‐ speed Ethernet connectivity .
Secure Networks Policy Support 1-4 Introduction Secure Networks Policy Support Po l i c y Enabled Netw orking manages the allocation of netw orking infrastructure resources in a secure and effecti ve manner .
Matrix DFE-Platinum Series Module Installation Guide 2-1 2 Network Requirements Before in stalling the module, review the requirements and specifications referred .
Module Placement in a Matrix E7 Chassis 2-2 Network Requirements The uplinks hav e one fiber ‐ optic interface with an LC conne ctor .
Matrix DFE-Platinum Series Module Installation Guide 3-1 3 Installation This chapter provides the instructions to install the DFE ‐ Diamond module and optional XFP interface modules.
Unpacking the DFE-Diamond Module 3-2 Installation Unp a cking the DFE-Diamond Module Unpack the DFE ‐ Diamond module as follows: 1. Open the box and remov e the packing material protecting the DFE ‐ Diamond module.
Backplane Connections and Installation Rules Matrix DFE-Platinum Series Module Installation Guide 3-3 Figure 3-1 Inst alling an XFP Removing an XFP Module To remove an XFP from the module port, refer back to Fi gure 3 ‐ 1 and proceed as follows: 1.
Backplane Connections and Installation Rules 3-4 Installation The DFE FT M bridging modules hav e a connection to both FTM 1 an d FT M 2 backplanes,.
Backplane Connections and Installation Rules Matrix DFE-Platinum Series Module Installation Guide 3-5 Example 2 ( Figure 3-1 , B) Shows the chassis fully populated with thi rd generation modules (6x3xx).
Installing Module into Matr ix E7 or Matrix N7 Chassis 3-6 Installation Example 6 ( Figure 3-1 , F) The module arrangement in this example is similar to the one shown in Figure 3 ‐ 1 , E and described in Example 5.
Installing Module into Matrix E7 or Matrix N7 Chassis Matrix DFE-Platinum Series Module Installation Guide 3-7 Inst allation To install the module, refer to Figure 3 ‐ 2 and proceed as follows: 1.
Installing Module into Matr ix E7 or Matrix N7 Chassis 3-8 Installation Figure 3-2 Ins talling Module into Matrix E7 or Matrix N7 Chassis 1 Card guides 5 Upper/lower locking tabs (in p roper open posi.
Installing Module into Matrix N3 Chassis Matrix DFE-Platinum Series Module Installation Guide 3-9 Inst alling Module into Matrix N3 Chassis A DFE ‐ Diamond module can be installed in any av ailable chassis slot (1 through 3).
Connecting to the Network 3-10 Installation Connecting to the Network Network Connection Using Fiber-Optic Cable To connect the module to the netw ork, refer to Figure 3 ‐ 4 and perform the following steps: 1.
Connecting to COM Port for Local Management Matrix DFE-Platinum Series Module Installation Guide 3-11 3. At the other end of the fiber ‐ optic cable, attach the SC connector to the other device.
Connecting to COM Port for Local Management 3-12 Installation •R J 4 5 ‐ to ‐ DB25 female adapter •R J 4 5 ‐ to ‐ DB25 male adapter Wi t h a UTP straight ‐ ca.
Connecting to COM Port for Local Management Matrix DFE-Platinum Series Module Installation Guide 3-13 Connecting to a VT Series T erminal To connect a VT Series terminal to .
Connecting to COM Port for Local Management 3-14 Installation When these parameters are set, the Local Management password screen will display . Refer to the Enterasys Matrix DFE ‐ Diamond/Platinum Serie s Configuration Guide for further information.
Connecting to COM Port for Local Management Matrix DFE-Platinum Series Module Installation Guide 3-15 Adapter Wiring and Signal Assignment s Figure 3-7 Connecting to a Modem 1 UTP straight-cable with .
Completing the Installation 3-16 Installation Completing the Inst allation Completing the DFE ‐ Diamond module ins tallation depends on if the module is b.
Completing the Installation Matrix DFE-Platinum Series Module Installation Guide 3-17 Completing the Inst all ation of a New System In a new system of DFE ‐ Diamond modules, .
Completing the Installation 3-18 Installation Figure 3-8 Matrix DFE St artup Screen Example (N7 Chassis) Completing Inst allation of DFE-Diam ond Module in an Existing System In an established.
Completing the Installation Matrix DFE-Platinum Series Module Installation Guide 3-19 The DFE ‐ Diamond module is now ready to be configured.
Completing the Installation 3-20 Installation.
Matrix DFE-Platinum Series Module Installation Guide 4-1 4 T roubleshooting This chapter provides information concerning the following: Unless otherwise noted, the following information applies to all DFE ‐ Diamond modules.
Using LANVIEW 4-2 Troubleshooting Ta b l e 4 ‐ 1 describes the LED indications and provides recommended actions as appropriate.
Using LANVIEW Matrix DFE-Platinum Series Module Installation Guide 4-3 CPU None Power off. Ensure chassis has a dequate power . Amber Blinking . Module i n process of booting. None. Solid . T esting. If the LED remains amber for several minutes, contact Enterasys Networks for technical support.
Troubleshooting Checklist 4-4 Troubleshooting T roubleshooting Checklist If the module is not work i ng properly , refer to Ta b l e 4 ‐ 2 for a checklist of problems, possible causes, and recommended actions to resolve the problem.
Overview of DFE-Diamond Module Shutdown Proced ure Matrix DFE-Platinum Series Module Installation Guide 4-5 Overview of DFE-Diamond Module Shut down Procedure The DFE ‐ Diamond modules i.
Overview of DFE-Diamond Module Shutdown Pro cedure 4-6 Troubleshooting Recommended Shut down Procedure Using OFFLINE/RESET Swi tch Before pulling a DFE ‐ Diamond module out of a chassis, press or tap on its OFFLINE/RESET switch for less than 1 second.
Overview of DFE-Diamond Module Shutdown Proced ure Matrix DFE-Platinum Series Module Installation Guide 4-7 Last Resort Shut down Proced ure Using OFFLINE/RESET Switch To reset a DFE ‐ D.
Overview of DFE-Diamond Module Shutdown Pro cedure 4-8 Troubleshooting.
Matrix DFE-Platinum Series Module Installation Guide A-1 A Specifications This appendix provides information about the foll owing: Enterasys Networks reserves the right to change the specifications at any time without notice.
10-Gigabit Ethernet Transceiver Specifications (XFP) A-2 Specifications 10-Gigabit Ethernet T ranscei ver Specifications (XFP) The 10 ‐ Gigabit XFP (10 ‐ Gigabit Small Form .
COM Port Pinout Assignments Matrix DFE-Platinum Series Module Installation Guide A-3 Ta b l e A ‐ 3 provides the input/output specifications for each XFP ver si on as specified in the IEEE 802.
Regulatory Compliance A-4 Specifications Regulatory Compliance The 7KR4297 ‐ 02 and 7KR4297 ‐ 04 modules meet the safety and electromagnetic compatibility .
Matrix DFE-Platinum Series Module Installation Guide B-1 B Mode Switch Bank Settings and Optional Installations This appendix covers the following items: Required T ools Use th.
Memory Locations and Replacement Procedures B-2 Mode Switch Bank Settings and Optional Installations •S w i t c h 7 – Clear Per s i s t e n t Data. Changing the position of this switch clears Pe r s i s t e n t Data on the next power ‐ up of the module.
Memory Locations and Replacement Procedures Matrix DFE-Platinum Series Module Installation Guide B-3 Location of DIMM and DRAM SIMM Memory Modules Figure B ‐ 2 shows the locations of the DIMM and DRAM SIMM on the main board.
Memory Locations and Replacement Procedures B-4 Mode Switch Bank Settings and Optional Installations 3. Pull the DRAM SIMM straig ht up and remo ve it from the connector finger s.
Memory Locations and Replacement Procedures Matrix DFE-Platinum Series Module Installation Guide B-5 DIMM Replacement Procedure In the event that the DIMM need s to be replaced, the following sections explain how to remove and install the DIMM.
Memory Locations and Replacement Procedures B-6 Mode Switch Bank Settings and Optional Installations 3. Rotate the DIMM upw ards, then remove it fro m the connector fingers. Inst alling the DIMM To install a DIMM, refer to Figure B ‐ 6 and proceed as follows: 1.
Memory Locations and Replacement Procedures Matrix DFE-Platinum Series Module Installation Guide B-7 Figure B-6 Installing the DIMM 1 DIMM 3 Connector arms 2 Connector fingers 4 DIMM alignment notches.
Memory Locations and Replacement Procedures B-8 Mode Switch Bank Settings and Optional Installations.
Index-1 Index Numerics 10GBASE-xx module installing a 3-2 10-Gigabit Ethernet Transcei ver Specifications (XFP) A-2 7KR4297-02 introduction to 1-2 7KR4297-04 Introduction to 1-2 A Acronyms commonly us.
Index-2.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Enterasys Enterasys Diamond Distributed Forwarding Engine 7KR4297-02 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Enterasys Enterasys Diamond Distributed Forwarding Engine 7KR4297-02 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Enterasys Enterasys Diamond Distributed Forwarding Engine 7KR4297-02 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Enterasys Enterasys Diamond Distributed Forwarding Engine 7KR4297-02 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Enterasys Enterasys Diamond Distributed Forwarding Engine 7KR4297-02, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Enterasys Enterasys Diamond Distributed Forwarding Engine 7KR4297-02.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Enterasys Enterasys Diamond Distributed Forwarding Engine 7KR4297-02. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Enterasys Enterasys Diamond Distributed Forwarding Engine 7KR4297-02 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.