Manuale d’uso / di manutenzione del prodotto Area-51 m5700 del fabbricante Alienware
Vai alla pagina of 47
SATA Host Controller User Manual Revision 1.01 May 19, 2003 VIA TECHNOLOGIES, INC..
Copyright Notice : Copyright © 2003 VIA Technologies Incorp orated. All Rights Reserved. No part of this document may be reprod uced, transmitted, transcribed, stored in a re trieval system, or trans.
VT6420 User Manual – SATA Controller Revision 1 .01 , May 19, 2003 i Revision History Revision History Document Release Date Revision Initials 1.0 5/15/03 Initial public release AT 1.
VT6420 User Manual – SATA Controller Revision 1 .01 , May 19, 2003 i Table of Contents Table of Contents Revision History............................................................................................................... ................
VT6420 User Manual – SATA Controller Revision 1 .01 , May 19, 2003 1 Introduction I NTRODUCTION This section gives a brief in troduction on the RA ID-related backg round knowledge and a br ief introduction on VIA SATA RAID Host Controller.
VT6420 User Manual – SATA Controller Revision 1 .01 , May 19, 2003 2 Introduction JBOD (Spanning) A spanning disk array is equal to th e sum of the all drives when the driv es used are having diff erent capacities. Spann ing sto res data onto a drive until it is full, th en proceeds to store files on to the next drive in th e array.
VT6420 User Manual – SATA Controller Revision 1 .01 , May 19, 2003 3 Installing The Hard Drives I NSTALLING T HE H ARD D RIVES The VT6420 SATA controller provides the fol lowing two configurati ons: 1.
VT6420 User Manual – SATA Controller Revision 1 .01 , May 19, 2003 4 BIOS Configuratio n Utility BIOS C ONFIGURATION U TILITY Enter BIOS Configuration Utility When the system powers on, the fo llowing information will appear on screen. Press the ‘Tab’ key to enter BIOS configuration utility.
VT6420 User Manual – SATA Controller Revision 1 .01 , May 19, 2003 5 BIOS Configuratio n Utility Create Disk Array 1. Use the arrow keys to navigate t he main m enu. Use the up and down a rrow keys t o select the Create Array comm and and press <Enter> to call out the list o f creation steps.
VT6420 User Manual – SATA Controller Revision 1 .01 , May 19, 2003 6 BIOS Configuratio n Utility 2. Select Array Mode and press <Enter>, a list of array modes will appear. Highlight the target array mode that you want to create, and press <Enter> to confirm the sel ection.
VT6420 User Manual – SATA Controller Revision 1 .01 , May 19, 2003 7 BIOS Configuratio n Utility 4. If user selects a RAID 0 array in step 2, the block si ze of the array can also be selected. Use the arrow key to highli ght Block Size and press <Enter>, then select a block size from the popup menu.
VT6420 User Manual – SATA Controller Revision 1 .01 , May 19, 2003 8 BIOS Configuratio n Utility Delete Disk Array A RAID can be deleted after it has been created . To delete a RAID, use the following steps: 1. Select Delete Array in the main menu and press <Enter>.
VT6420 User Manual – SATA Controller Revision 1 .01 , May 19, 2003 9 BIOS Configuratio n Utility Create and Delete Spare Hard Drive If a RAID 1 array is created and there are drives that do not be l.
VT6420 User Manual – SATA Controller Revision 1 .01 , May 19, 2003 10 BIOS Configuratio n Utility Select Boot Array User can select a disk array as boot de vice if user wants to b oot o perating system from an array. Boot di sk array cann ot be selected if the operatin g system does not b oot from the disk array .
VT6420 User Manual – SATA Controller Revision 1 .01 , May 19, 2003 11 BIOS Configuratio n Utility View Serial Number of Hard Drive Highlight Serial Number View and press <Enter>. Use arrow key to select a dri ve, the selected drive’s serial number can be viewed in the last colum n.
VT6420 User Manual – SATA Controller Revision 1 .01 , May 19, 2003 12 BIOS Configuratio n Utility Duplicate Critical RAID 1 Array When booting up the system, BIOS will detect if the RAID 1 arra y has any incon sistencies between user data and b ackup data.
VT6420 User Manual – SATA Controller Revision 1 .01 , May 19, 2003 13 BIOS Configuratio n Utility Rebuild Broken RAID 1 Array When booting up the system, BIOS will detect if any member disk drives of RAID has failed or is absent. If BIOS detects any disk drive failures or missing disk d rives, the status of the array will b e marked as broken.
VT6420 User Manual – SATA Controller Revision 1 .01 , May 19, 2003 14 BIOS Configuratio n Utility 1. Power off and Check the Failed Drive: This item turns off t he computer and replaces the failed hard dr ive with a good one. If your co m puter does not support APM, you must turn off your co mputer manu ally.
VT6420 User Manual – SATA Controller Revision 1 .01 , May 19, 2003 15 Driver and RAID Software Installation D RIVER AND RAID S OFTWARE I NSTALLATION Microsoft Windows Driver Installation 1. After Windows has finished booting up, th e system will au tomatically find the newly installed adapter and prompt the Found New Hardware Wizard window.
VT6420 User Manual – SATA Controller Revision 1 .01 , May 19, 2003 16 Driver and RAID Software Installation 3. Confirm t he follow-up dialogue windows to fi nish the installa tion. 4. When in stallation is completed, click Finish to restart the system.
VT6420 User Manual – SATA Controller Revision 1 .01 , May 19, 2003 17 Driver and RAID Software Installation Verify Installation After the driver installation is completed and the system has restarted: 1. Right-clic k on My Computer and select Properties from t he popup menu.
VT6420 User Manual – SATA Controller Revision 1 .01 , May 19, 2003 18 RAID Software RAID S OFTWARE Installation The RAID software is installed simultaneously with d river installation.
VT6420 User Manual – SATA Controller Revision 1 .01 , May 19, 2003 19 RAID Software Getting Start After installing the GUI software, it will be automatically started every time Windows is initiated. An icon will appear in the system t ray of the tool bar to indicat e that GUI software is currently running.
VT6420 User Manual – SATA Controller Revision 1 .01 , May 19, 2003 20 RAID Software The main interface is divide d into two windo ws and the toolbar above contain the m ain functions. Click on t hese toolbar button s to execute t heir specifi c funct ions.
VT6420 User Manual – SATA Controller Revision 1 .01 , May 19, 2003 21 RAID Software View Online Help Click on to launch the Help Topics. It is recomme nded that y ou read through the help article s before using RAID utility.
VT6420 User Manual – SATA Controller Revision 1 .01 , May 19, 2003 22 RAID Software View Controller and Device Status Click on or button to determine the viewing type of left window pane. T here are tw o viewi ng types : By cont rollers and by device.
VT6420 User Manual – SATA Controller Revision 1 .01 , May 19, 2003 23 RAID Software Create Disk Array 1. Depending on users’ pre ferences, there are three butt ons used t o create a dis k array: RAID 1, Span, and RAID 0. Click on the RAID but ton you want to create, t he Select Array Creating Method will be displayed.
VT6420 User Manual – SATA Controller Revision 1 .01 , May 19, 2003 24 RAID Software 2. Click on Auto to la unch the creati ng array wi ndow. If Custom is selected, the available disks window lists the available disk drives that can be used t o create the array.
VT6420 User Manual – SATA Controller Revision 1 .01 , May 19, 2003 25 RAID Software 3. A warning message will pop up after clicking on Create button.
VT6420 User Manual – SATA Controller Revision 1 .01 , May 19, 2003 26 RAID Software Delete Disk Array 1. Select the disk array that you w ant to delete from the left w indowpane, click on Remove Arr ay , a warning m essage will pop up. 2. Clic k Yes to delete the specified disk array o r click No to cancel.
VT6420 User Manual – SATA Controller Revision 1 .01 , May 19, 2003 27 RAID Software 3. A message box will popup to prompt the user that disk array ha s been removed successfully and ask the user whether to restar t the computer. Click Yes to restart the com puter or click No to skip restarting.
VT6420 User Manual – SATA Controller Revision 1 .01 , May 19, 2003 28 RAID Software Add and Remove Spare Disk Drive Add Spare Disk Drive A spare disk drive can be a dded when a RAID 1 array is created. The capacity of the sp are dis k drive must be greater than or equal to the capacity of the RAID 1 array.
VT6420 User Manual – SATA Controller Revision 1 .01 , May 19, 2003 29 RAID Software 4. A message box will popup to prom pt the us er that a spare disk drive has been succes sfully a dded to the specific R AID 1 array , and ask whether the user would like to restart the computer.
VT6420 User Manual – SATA Controller Revision 1 .01 , May 19, 2003 30 RAID Software Remove Spare Disk Drive Spare disk drives can be removed from a specified RAID 1 and changed into norm al hard disk drives.
VT6420 User Manual – SATA Controller Revision 1 .01 , May 19, 2003 31 RAID Software Check All Disks You can check whet her the di sk drives are working no rmally at any time by cli cking on . After the disk check is completed, a dialog window will pop up to show the stat us of each disk.
VT6420 User Manual – SATA Controller Revision 1 .01 , May 19, 2003 32 RAID Software View Event Log The RAID software records important events into a log file, su ch as disk array creation, dis k array removal, disk failure, synchronization…etc. 1.
VT6420 User Manual – SATA Controller Revision 1 .01 , May 19, 2003 33 RAID Software 2. To view the de tails of a log item, you can double click on th e log item, select the log item and press <Enter>, or select th e log item and click on Operation->View Detail in the m enu bar.
VT6420 User Manual – SATA Controller Revision 1 .01 , May 19, 2003 34 RAID Software Verify Mirror Disk The data on the mi rror disk must be the sam e with its corresponding source disk to provide fault tole rance for RAID 1. 1. Select a RAID 1 array.
VT6420 User Manual – SATA Controller Revision 1 .01 , May 19, 2003 35 RAID Software 2. After executing the “v erify mirror” command, a dialog box will show th e verifying process. This action can paused or cancel ed at any tim e. It may take a long tim e to verify the source and m irror disk if the capacity of the RAID is large.
VT6420 User Manual – SATA Controller Revision 1 .01 , May 19, 2003 36 RAID Software Synchronize Mirror Disk RAID 1 arrays must be synchron ized when the data on th e mirro r disk is not identical with its corresp onding source disk. Sometimes t he data on the m i rror disk m ay be newe r than the dat a on the source disk.
VT6420 User Manual – SATA Controller Revision 1 .01 , May 19, 2003 37 RAID Software 2. After synchronization has star ted, a dialog box will show the process. This action can be paused or canceled at any time. 3. An informing message will appear when the synchro nization is finished.
VT6420 User Manual – SATA Controller Revision 1 .01 , May 19, 2003 38 RAID Software Disk Error Detection The RAID software will pop up an error messa ge if a disk drive fails or m issing.
VT6420 User Manual – SATA Controller Revision 1 .01 , May 19, 2003 39 RAID Software Duplicate Critical RAID 1 Array When booting up the system, the RAID utility will detect if th ere are any inconsistencies between the sour ce and mirror disk dr ives of the RAID 1 array.
VT6420 User Manual – SATA Controller Revision 1 .01 , May 19, 2003 40 RAID Software Rebuild Broken RAID 1 Array After booting up the system, the RAID utility will detect if any me mber disk drives of the RAID 1 array has failed or is absent .
VT6420 User Manual – SATA Controller Revision 1 .01 , May 19, 2003 41 RAID Software 3. Select a disk drive from Available Disks and click on to replace the broken drive and then click Next .
VT6420 User Manual – SATA Controller Revision 1 .01 , May 19, 2003 42 RAID Software 4. A warning message will appear. If you want to rebuild the RAID using the disk driver that you selected in the previous step , click Next . Warning: All the data on the selected d isk drive will be lost.
VT6420 User Manual – SATA Controller Revision 1 .01 , May 19, 2003 43 RAID Software Icon View All icon t ypes and their cor respondi ng meani ngs are li sted belo w. The re al status of an array or a di sk dri ve is descri bed on “Array status” or “Device status” in the right windowpane.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Alienware Area-51 m5700 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Alienware Area-51 m5700 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Alienware Area-51 m5700 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Alienware Area-51 m5700 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Alienware Area-51 m5700, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Alienware Area-51 m5700.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Alienware Area-51 m5700. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Alienware Area-51 m5700 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.