Net Weight: 30.9 Lbs. Part No. F40BP72840003 Form No. BP7284-3 U.L. Model No.: KF180 READ AND SA VE THESE INSTRUCTIONS KF180AP01 Antique P ewter with Natural Cher r y/Mahogany Blades KF180OZ01 Olde Br.
W ARNING: T o avoid fire, shock, and serious personal injury , follow these instructions. Safety Instructions 1. Read your owner ’ s manual carefully and keep it for future reference.
3 T ools Needed for Assembly One Phillips head screwdriver One wire stripper Six wire connectors (supplied) Three 60-watt (max.) candelabra base bulbs Materials Wiring, outlet box and box connectors must be of type required by the local code.
Preset Memory Feature Y our remote control receiver is equipped with a preset memory feature. The receiv- er will remember the light intensity and fan speed when the light and fan are turned off from the wall switch. When the wall switch is turned back on, the lights and fan will resume operation as they were prior to the switch being turned off.
2. Slide the four switch levers on the code switch to your choice of ON (up) or down positions. Use a ball-point pen or small screwdriver and slide the levers firmly up or down. 3. In the receiver (Figure 1), slide the four switch levers to the same positions as set in the transmitter .
6 It is critical that the clevis pin in the motor coupling is properly installed and the setscrews securely tight- ened. Failure to verify that the pin and setscrews are properly installed (as shown in Figure 3) could result in the fan falling. ! W ARNING HAIRPIN CLIP DOWNROD CLEVIS PIN MOTOR COUPLIN G SETSCREW (2) Figure 3 3.
7 8. T urn the fan motor and housing assem- bly upside down in preparation for mounting the fan blade assemblies. Remove and discard the three shipping retainers securing the motor hub in the motor housing. NOTE: T ake care not to scratch the fan housing when installing the blade assemblies.
2. Carefully lift the fan and seat the hang- er ball/downrod assembly on the hang- er bracket that was just attached to the outlet box (Figure 1 1). Be sure the groove in the ball is lined up with the tab on the hanger bracket (Figure 10).
9 1. Position the supply wires to the left side of the outlet box (Figure 12); position the fan wires to the right side. Partially insert the remote control receiver (flat side up) until one end rests on the hanger ball as shown in Figure 12. NOTE: Make all wiring connections using wire connectors (supplied).
7. Screw three 60-watt (maximum) cande- labra base flame bulbs into the light fitter sockets (Figure 15). 8. Unscrew the six ring screws from the lower ring assembly (Figure 15). Position the lower glass in the lower ring assembly so that the six channels in the glass align with the six arms of the lower ring assembly .
button is held down. When the light is at the desired brightness, release the button. 5. T o turn the light on and off, press and release the button. The light will turn on at the light level previously set (see step 4). 6. If airflow is desired in the opposite direction, turn the fan off and wait for the blades to stop turning.
12 Do not use water when cleaning your ceiling fan. It could damage the motor or the blades and create the possibility of an electrical shock. ! W ARNING The use of any other control not specifically approved for this fan could result in fire, shock and per- sonal injury .
13 T rouble Shooting TROUBLE PROBABLE CAUSE SUGGESTED REMEDY 1. Fan will not 1. Fuse or circuit breaker 1. Check main and branch start. blown. circuit fuses or circuit breakers. 2. Loose power line 2. Check line power connections connections to the fan, or to fan and wire.
14 Repair Parts 10 16 12 3 2 1 5 4 7 6 14 21 19 23 H I OFF LOW MED 24 11 15 13 9 17 20 25 8 22 18 BP7284, Sturbrige, KF180 7/31/06 10:52 AM Page 14.
Part Numbers Key Model No. Model No. Model No. N o . Description KF180AP01 KF180DBK01 KF180OZ01 * Hanger Pack, Consisting of: 761655-34 761655-36 761655-35 1 Hanger Bracket — — — 2 Hanger Ball .
LIMITED WARRANTY What The War ranty Covers: This warranty covers the motor and the other components and accessories of your Emerson ceiling fan against all defects in workmanship and materials. Y ou must be the original purchaser or user of the product to be covered.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Emerson KF180 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Emerson KF180 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Emerson KF180 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Emerson KF180 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Emerson KF180, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Emerson KF180.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Emerson KF180. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Emerson KF180 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.