READ AND SA VE THESE INSTRUCTIONS Model No. CF929BS 00 CF929WW 00 MIDW A Y II ™ Part No. F40BP72690000 Form No. BP7269 ® Net Weight: 23.8 Lbs. 54” Ceiling Fan Owner's Manual LIMITED WARRANTY.
2 WARNING: To avoid fire, shock, and serious personal injury, follow these instructions. Safety Instructions 1. Read your owner’s manual carefully and keep it for future reference.
1. Check to see that you have received the following parts: NOTE: If you are uncertain of part description, refer to exploded view illustration. a. Fan motor assembly b. One lower housing assembly c. One ceiling cover d. Five fan blades e. One hanger ball/downrod assembly f.
1. Remove the hanger ball by loosening the setscrew in the hanger ball until the ball falls freely down the downrod (Figure 1). Remove the clevis pin from the downrod, then remove the hanger ball. Retain the pin and hanger ball for reinstallation in step 5.
NOTE: Take care not to scratch fan housing when installing blades. 9. Remove two of the four screws in the motor assembly and loosen the remaining two screws (Figure 6). 10. Connect the terminals of the lower housing assembly to the terminals of the fan motor assembly (Figure 6).
If you feel that you do not have enough electrical wiring knowledge or experience, have your fan installed by a licensed electrician. 1. Your ceiling fan is supplied with an Emerson Fan/Light Control. Wire your ceiling fan in accordance with the Owner’s Manual supplied with the Fan/Light Control.
7 Installing Glass Globe 1. Engage the connector of the ballast, in the lower housing assembly, onto the fluorescent lamp plug (Figure 12). 2. Carefully push the fluorescent bulb (supplied) into the two spring clamps until the clamps secure the lamp. 3.
8 1. Restore electrical power to the outlet box by turning the electricity on at the main fuse box. 2. Remove the battery cover by pressing firmly on the arrow and sliding the cover off the control transmitter. 3. Engage the connector in the transmitter with the terminals of a 9-volt alkaline battery (not supplied) (Figure 13).
9 T r ouble Shooting TROUBLE PROBABLE CAUSE SUGGESTED REMEDY 1. Fan will not start. 1. Fuse or circuit breaker blown. 1. Check main and branch circuit fuses or circuit breakers. 2. Loose power line connections to the fan, or loose 2. Check line wire connections to fan and switch wire switch wire connections in the switch housing.
IMPORTANT CARE INSTRUCTIONS for your Ceiling Fan Periodic cleaning of your new ceiling fan is the only maintenance that is needed. When cleaning, use only a soft brush or lint free cloth to avoid scratching the finish. Abrasive cleaning agents are not required and should be avoided to prevent damage to finish.
11 9 4 15 11 6 1 2 3 7 5 14 16 18 17 8 19 10 13 FAN/OFF FOR/REV LIGHT DIMMER HI MED LOW ® 12 Repair Par ts.
Key Model No. N o . Description CF929WW 00 CF929BS 00 — Hanger Ball Assembly, 761655 761655-17 Consisting of: 1 Hanger Bracket — — 2 Hanger Ball — — 3 Downrod — — — Parts Bag Containin.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Emerson CF929WW 00 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Emerson CF929WW 00 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Emerson CF929WW 00 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Emerson CF929WW 00 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Emerson CF929WW 00, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Emerson CF929WW 00.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Emerson CF929WW 00. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Emerson CF929WW 00 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.