Part No. F40BP72400001 Form No. BP7240-1 READ AND SA VE THESE INSTRUCTIONS Model No. CF759OB00 CF759PB00 CF759TG00 CF759HTW00 CF759BS00 CF759AB00 CF759WW00 DESIGNER REMOTE Series ® Ceiling Fan Owner&.
2 W ARNING ! WARNING: To avoid fire, shock, and serious personal injury, follow these instructions. Safety Instructions 1. Read your owner’s manual carefully and keep it for future reference.
This Manual Is Designed to Make it as Easy as Possible for Y ou to Assemble, Install, Operate and Maintain Y our Ceiling Fan T ools Needed for Assembly One Phillips head screwdriver One stepladder One 1/4” blade screwdriver One wire stripper Three wire connectors (supplied).
4 How to Put Y our Ceiling Fan T ogether 1. Remove the hanger ball by loosening the setscrew in the hanger ball until the ball falls freely down the downrod (Figure 1). Remove the pin from the downrod, then remove the hanger ball. Retain the pin and hanger ball for reinstallation in step 5.
7. Remove the three switch housing mounting screws (Figure 5) from the switch housing plate. Position the switch housing assembly on the switch hous- ing plate and align the holes in the switch housing assembly with the holes in the plate. Secure the switch housing assembly by installing the three screws (Figure 6).
If you feel that you do not have enough electrical wiring knowledge or experience, have your fan installed by a licensed electrician. 1. Connect the green grounding lead from the hanger ball and the green grounding lead from the hanger bracket to the grounding conductor of supply (this may be a bare wire or wire with green colored insulation).
7 3. Screw the two threaded studs (supplied) into the tapped holes in the hanger bracket. 4. Lift the ceiling cover up to the threaded studs and turn until studs protrude through the holes in the ceiling cover (Figure 13).
8 F AN/OFF FOR/REV LIGHT DIMMER HIGH MED LOW ® Figure 17 Operation of Y our Remote Contr ol 1. To set the desired fan speed, push the HI, MED or LOW buttons to set your fan on high, medium or low speed. (See Figure 17). 2. To reverse the direction the fan is turning, press the FOR/REV button.
9 T r ouble Shooting TROUBLE PROBABLE CAUSE SUGGESTED REMEDY 1. Fan will not start. 1. Fuse or circuit breaker blown. 1. Check main and branch circuit fuses or circuit breakers. 2. Loose power line connections to the fan, or loose 2. Check line wire connections to fan and switch switch wire connections in the switch housing.
Repair Par ts Listing Part Numbers Key Model No. Model No. Model No. Model No. Model No. Model No. Model No. N o. Description CF759AB00 CF759PB00 CF759OB00 CF759TG00 CF759BS00 CF759HTW00 CF759WW00 * H.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Emerson CF759TG00 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Emerson CF759TG00 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Emerson CF759TG00 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Emerson CF759TG00 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Emerson CF759TG00, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Emerson CF759TG00.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Emerson CF759TG00. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Emerson CF759TG00 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.