LIMITED WARRANTY What The War ranty Covers: This warranty covers the motor and the other components and accessories of your Emerson ceiling fan against all defects in workmanship and materials. Y ou must be the original purchaser or user of the product to be covered.
2 W ARNING: T o avoid fire, shock, and serious personal injury , follow these instructions. Safety Instructions 1. Read your owner ’s manual carefully and keep it for future reference.
3 This Manual is Designed to Make it as Easy as Possible for Y ou to Assemble, Install, Operate and Maintain Y our Ceiling Fan Do not install or use fan if any part is damaged or missing.
4 Y our new ceiling fan will require a grounded electrical supply line of 120 volts AC, 60 Hz, 15 amp circuit. The outlet box must be securely anchored and capable of withstanding a load of at least 50 pounds.
5 3. Pass the outlet box supply wires (black, white and ground) through the center hole in the mounting plate and securely attach the mounting plate to the outlet box using the screws supplied with the outlet box (Figure 3). NOTE: In order for the fan housing to fit flush with the ceiling, the outlet box must not protrude below the ceiling.
6 NOTE: Make all wiring connections using wire connectors (supplied). Make sure that all connections are tight, including ground, and that no bare wire is visible at the wire connectors, except for the ground wire. 5. Refer to Figures 5 and 6 and connect the receiver wires to the supply wires and the fan motor wires as follows: a.
9. Align the two indents on the inside of the motor housing with the two tabs on the mounting plate (Figure 8). T urn the housing clockwise to hold the housing on the mounting plate. Secure the housing to the mounting plate by installing four pointed M5 x 12mm pan head screws with lockwashers (supplied).
8 M5 x 6mm WASHER HEAD SCREWS (3) CAPTIVE SCREWS (2) BLADE FLANGE F AN BLADE Figure 9 10. Mount one blade flange to a fan blade using three M5 x 6mm washer head screws (supplied) (Figure 9).
9 18. Screw in two 60-watt (maximum) candelabra bulbs in the light fitter sockets (Figure 12). Bulbs not supplied. 19. Place the lower glass into the light fitter , aligning the three flat areas on the lower glass flange with the three tabs on the light fitter (Figure 13).
4. Install a wall control in the wall box containing the “hot” wire first. Connect the black wire of the wall control to the “hot” wire. Securely connect wires with wire connectors supplied. 5. Connect one black wire of the wall control to both remaining traveler wires in the wall box and secure with wire connector supplied.
NOTE: Retrofit 3-way installations are likely to include two traveler wires between the two wall boxes. In new construction, only one traveler wire Is required. 3-WA Y WIRlNG DIAGRAM: NEW CONSTRUCTION 6. Place wall control into wall box. Screw in place and install decorator style faceplate (included).
12 Operating Y our Ceiling Fan IMPORT ANT Fan installation must be completed, including the installation of the fan blades, before testing of the remote control. Y our Fan/Light Wall Control (Figure 19) has full control of your fan and light. However , airflow direction is controlled by a pull chain on the light fitter switch.
13 Do not use water when cleaning your ceiling fan. It could damage the motor or the blades and create the possibility of an electrical shock. ! W ARNING Maintenance IMPORT ANT CARE INSTRUCTIONS for your Ceiling Fan Periodic cleaning of your new ceiling fan is the only maintenance that is needed.
Repair Parts 8 17 18 9 10 13 12 2 11 4 3 16 14 15 7 5 HI MED LOW FAN OFF LIGHT ON OFF EMERSON 1 6 Before discarding packaging material, be certain all parts have been removed.
15 Part Numbers Key Model No. Model No. Model No. N o . Description CF730WB00 CF730BZH00 CF730AGW00 1 Plate, Mounting 763139 763139 763139 2 Housing, Fan 763126-WB 763126-BZH 763126-AGW 3 Flange Set (.
Part No. F40BP73150000 Printed in China 03/06 Form No. BP7315 Air Comfort Products DIVISION OF EMERSON ELECTRIC CO. 8100 W. Florissant ¥ St. Louis, MO 63136 T rouble Shooting TROUBLE PROBABLE CAUSE SUGGESTED REMEDY 1. Fan will not 1. Fuse or circuit breaker 1.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Emerson CF730 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Emerson CF730 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Emerson CF730 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Emerson CF730 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Emerson CF730, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Emerson CF730.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Emerson CF730. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Emerson CF730 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.