Manuale d’uso / di manutenzione del prodotto CF705BC04 del fabbricante Emerson
Vai alla pagina of 12
Part No. F40BP72240007 Form No. BP7224-7 U.L. Model No.: CF705 READ AND SA VE THESE INSTRUCTIONS Model No. CF705AB04 CF705AGW04 CF705A W04 CF705BC04 CF705BS04 CF705BZH04 CF705CK04 52” NOR THWIND ® Net Weight: 16.
2 U.L. Model No.: CF705 W ARNING ! WARNING: To avoid fire, shock, and serious personal injury, follow these instructions. Safety Instructions 1. Read your owner’s manual carefully and keep it for future reference.
1. Check to see that you have received the following parts: NOTE: If you are uncertain of part description, refer to exploded view illustration. a. Fan motor assembly b. One switch housing assembly c. Five fan blades d. One ceiling cover e. Five blade flanges f.
NOTE: Take care not to scratch fan housing when installing blades. NOTE: Remove and discard the four shipping spacers and screws from the motor hub. 7. Turn the fan assembly upside down in preparation for mounting the fan blade assemblies. 8. Rotate the motor hub until the flange screw hole is next to the cutout in the switch housing plate.
5 U.L. Model No.: CF705 11. Remove the three switch housing mounting screws (Figure 4) from the switch housing plate. Position the switch housing assembly on the switch housing plate and align the holes in the switch housing assembly with the holes in the plate.
6 U.L. Model No.: CF705 OUTLET BOX HANGER BRACKET HANGER BALL/ DOWNROD ASSEMBL Y Figure 3 NOTE: CEILING COVER, SUPPL Y WIRES AND F AN WIRES OMITTED FOR CLARITY . Figure 8 2. Carefully lift the fan and seat the hanger ball/ downrod assembly on the hanger bracket that was just attached to the outlet box (Figure 8).
5. Secure the ceiling cover in place by sliding lock- washers over the threaded studs and installing the two knurled knobs (supplied). (Figure 10.) Tighten the knurled knobs securely until the ceiling cover fits snugly against the ceiling and the hole in the ceiling cover is clear of the downrod.
1. Restore electrical power to the outlet box by turning the electricity on at the main fuse box. 2. Check the operation of the fan by gently pulling on the pull chain switch. All fans are shipped from the factory with the revers- ing switch positioned “down” to circulate air downward.
9 U.L. Model No.: CF705 T r ouble Shooting TROUBLE PROBABLE CAUSE SUGGESTED REMEDY 1. Fan will not start. 1. Fuse or circuit breaker blown. 1. Check main and branch circuit fuses or circuit breakers. 2. Loose power line connections to the fan, or loose 2.
18 10 9 16 17 15 13 12 8 7 6 4 5 1 2 3 11 14 Repair Par ts Before discarding packaging material, be certain all parts have been removed. HOW TO ORDER REP AIR P ARTS WHEN ORDERING REPAIR PARTS, ALWAYS .
11 U.L. Model No.: CF705 Key Model No. N o. Description CF705WW04 CF705PB04 CF705AB04 CF705BS04 CF705SCB04 CF705HTW04 * Hanger Ball Assembly, 760750-3 760750-1 760750 760750-24 760750-36 760750-34 Con.
Air Comfort Products &+8+5+101('/'4510'.'%64+%%1 9(NQTKUUCPVć5V.QWKU/1 Part No.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Emerson CF705BC04 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Emerson CF705BC04 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Emerson CF705BC04 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Emerson CF705BC04 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Emerson CF705BC04, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Emerson CF705BC04.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Emerson CF705BC04. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Emerson CF705BC04 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.