Part No. F40BP73360000 Form No. BP7336 U.L. Model No.: CF654 READ AND SA VE THESE INSTRUCTIONS Model No. CF654A W00 CF654ORB00 CF654WB00 CF654WW00 SEA BREEZE Net Weight: 18.
2 WARNING: To avoid fire, shock, and serious personal injury, follow these instructions. Safety Instructions 1. Read your owner’s manual carefully and keep it for future reference.
T ools Needed for Assembly One Phillips head screwdriver One stepladder One wire stripper Three wire connectors (supplied). MA TERIALS Wiring, electrical box and box connectors must be of type required by the local code. The minimum wiring would be a 3-conductor (2-wire with ground) of follow- ing sizes: Installed Wire Length Wire Size A.
How to Put Y our Ceiling Fan T ogether 1. Remove the hanger ball by loosening the setscrew in the hanger ball until the ball falls freely down the downrod (Figure 1). Remove the pin from the downrod, then remove the hanger ball. Retain the pin and hanger ball for reinstallation in step 5.
Your new ceiling fan will require a grounded electrical supply line of 120 volts AC, 60 Hz, 15 amp circuit. The outlet box must be securely anchored and capa- ble of withstanding a load of at least 50 pounds.
1. Securely attach the hanger bracket to the outlet box using the two screws supplied with the outlet box (Figure 8). A T LEAST 7' CEILING FLOOR How to Hang Y our Ceiling Fan Figure 7 TWO SCREWS SUPPLIED WITH OUTLET BOX HANGER BRACKET TA B OUTLET BOX Figure 8 OUTLET BOX HANGER BRACKET HANGER BALL/ DOWNROD ASSEMBL Y Figure 9 2.
3. Screw the two threaded studs (supplied) into the tapped holes in the hanger bracket. 4. Lift the ceiling cover up to the threaded studs and turn until studs protrude through the holes in the ceiling cover (Figure 11).
1. Restore electrical power to the outlet box by turning the electricity on at the main fuse box. 2. Check the operation of the fan by gently pulling on the pull chain switch. 3. All fans are shipped from the factory with the reversing switch positioned “down” to circulate air downward.
T rouble Shooting W ARNING: FOR YOUR OWN SAFETY TURN OFF POWER A T FUSE BOX OR CIRCUIT BREAKER BEFORE TROUBLE SHOOTING YOUR F AN. TROUBLE PROBABLE CAUSE SUGGESTED REMEDY 1. Fan will not start. 1. Reversing switch in neutral position. 1. Make sure reversing switch position is all the way to one side.
2 1 1 9 9 9 5 9 9 9 8 9 9 9 3 6 7 9 4 Before discarding packaging material, be certain all parts have been removed. HOW TO ORDER REP AIR P ARTS WHEN ORDERING REPAIR PARTS, ALWAYS GIVE THE FOLLOWING IN.
Repair Parts Listing Key Service Part No. N o. Description CF654WW01 CF654WB00 CF654AW00 CF654ORB00 1 Hanger Assembly 761655 761655-20 761655-21 761655-32 2 Ceiling Cover 760169 760169-30 760169-32 76.
Form No. BP7336-1 Part No. F40BP73360001 Printed in China 11/08 Air Comfort Products DIVISION OF Emerson Electric Co. 8100 W. Florissant ¥ St. Louis, MO 63136 LIMITED WARRANTY What The Warranty Cover.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Emerson CF654AW00 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Emerson CF654AW00 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Emerson CF654AW00 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Emerson CF654AW00 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Emerson CF654AW00, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Emerson CF654AW00.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Emerson CF654AW00. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Emerson CF654AW00 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.