Manuale d’uso / di manutenzione del prodotto CF4501AP00 del fabbricante Emerson
Vai alla pagina of 16
Part No. F40BP74470000 Form No. BP7447 U.L. Model No.: CF4801 and CF4501 READ AND SA VE THESE INSTRUCTIONS Ceiling F an Owner's Manual CF4801AB00 CF4801AP00 CF4801BS00 CF4801CK00 CF4801GBZ00 CF48.
WARNING: To avoid fire, shock, and serious personal injury, follow these instructions. Safety Instructions 1. Read your owner’s manual carefully and keep it for future reference. 2. Before servicing or cleaning unit, switch power off at service panel and lock service panel disconnecting means to prevent power from being switched on accidentally.
3 Unpac king Instr uctions 1. Check to see that you have received the following parts: NOTE: If you are uncertain of part description, refer to exploded view illustration. a. Fan motor and housing assembly b. One motor cover c. One ceiling cover d. Five blade flanges e.
4 U.L. Model No.: CF4801 and CF4501 Electrical R equir ements Ho w to Put Y our Ceiling F an T ogether SETSCREW CLEVIS PIN MOTOR COUPLING DOWNROD HAIRPIN CLIP MOTOR COUPLING HAIRPIN CLIP CLEVIS PIN DO.
5 U.L. Model No.: CF4801 and CF4501 Ho w to Put Y our Ceiling F an T ogether (continued) 6. Install the setscrew (supplied in loose parts bag) in the motor coupling and tighten using the 5/32" setscrew wrench (supplied) (Figure 3). 7. Screw two 1” threaded studs (provided) into the motor (Figure 4).
6 U.L. Model No.: CF4801 and CF4501 11. Use four #10-24 x 12mm pan head screws and flat washers (supplied) to secure flange to blade (Figure 6). Repeat for the remaining four blades.
7 U.L. Model No.: CF4801 and CF4501 Ho w to Hang Y our Ceiling F an The fan must be hung with at least 7' of clearance from floor to blades (Figure 9). CEILING FLOOR A T LEAST 7' Figure 9 WARNING ! The outlet box and joist must be securely mounted and capable of supporting at least 50 lbs.
8 U.L. Model No.: CF4801 and CF4501 Ho w to W ir e Y our Ceiling F an If you feel that you do not have enough electrical wiring knowledge or experience, have your fan installed by a licensed electrician. 1. For a wall control installation you will need a three- wire (with ground) conductor cable between the ceiling and wall outlet boxes.
9 Using Y our Ceiling F an 25-WA TT (Max.) CANDELABRA BASE LAMPS (3) UPLIGHT SOCKETS (3) Figure 14 SPEED CONTROL PULL CHAIN ACCENT LIGHT PULL CHAIN PENDANT COUPLING REVERSE SWITCH LARGE PENDANT COUPLING Figure 15 1.
Accessories This product is designed to use only those parts supplied with this product and/or any accessories designated specifically for use with this product by Emerson Electric Co. Substitution of parts or accessories not designated for use with this product by Emerson Electric Co.
11 U.L. Model No.: CF4801 and CF4501 T r ouble Shooting WARNING: For your own safety, turn off power at fuse box or circuit breaker before trouble shooting your fan. TROUBLE PROBABLE CAUSE SUGGESTED REMEDY 1. Fan will not start. 1. Fuse or circuit breaker blown.
12 R epair Par ts 6 13 1 2 3 16 14 15 7 10 20 19 24 18 17 5 4 23 27 12 11 29 30 25 26 31 18 28 32 11 12 33 22 8 21 9 U.L. Model No.: CF4801 and CF4501.
13 Cr o wn Select R epair Par ts Listing Before discarding packaging material, be certain all parts have been removed. HOW TO ORDER REP AIR P ARTS WHEN ORDERING REPAIR PARTS, ALWAYS GIVE THE FOLLOWING INFORMATION: • PART NUMBER • PART DESCRIPTION • NAME OF ITEM • MODEL NUMBER For repair parts, phone 1-800-654-3545.
14 U.L. Model No.: CF4801 and CF4501 Pr emium Select R epair Par ts Listing Ref. Premium Select Series No. Description CF4801AB00 CF4801AP00 CF4801BS00 CF4801CK00 CF4801GBZ Hanger Pack, 761655-3 76165.
15 U.L. Model No.: CF4801 and CF4501 Pr emium Select R epair Par ts Listing Ref. Premium Select Series No. Description CF4801GES00 CF4801ORB00 CF4801VNB00 CF4801WW00 Hanger Pack, 761655-35 761655-32 7.
Part No. F40BP74470000 Printed in China 01/12 Form No. BP7447 Air Comfort Products DIVISION OF EMERSON ELECTRIC CO. 8100 W. Florissant • St. Louis, MO 63136 U.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Emerson CF4501AP00 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Emerson CF4501AP00 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Emerson CF4501AP00 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Emerson CF4501AP00 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Emerson CF4501AP00, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Emerson CF4501AP00.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Emerson CF4501AP00. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Emerson CF4501AP00 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.