Manuale d’uso / di manutenzione del prodotto CF3100AGW00 del fabbricante Emerson
Vai alla pagina of 16
READ AND SA VE THESE INSTRUCTIONS Part No. F40BP73610000 Form No. BP7361 U.L. Model No.: CF3100 Net Weight: 26.0 Lbs. Model Numbers DUNNINGT ON ™ Ceiling F an Owner's Manual CF3100A GW00 Aged W.
2 WARNING WARNING: To avoid fire, shock, and serious personal injury, follow these instructions. Safety Instructions 1. Read your owner’s manual carefully and keep it for future reference 2 .
3 This Manual Is Designed to Make it as Easy as Possible for Y ou to Assemble, Install, Operate and Maintain Y our Ceiling Fan One stepladder One wire stripper One Phillips head screwdriver Three 15-watt (max.) candelabra base bulbs (not supplied) MA TERIALS Wiring outlet box and box connectors must be of type required by the local code.
1. Place the flange assembly onto the blade. Place the flange medallion assembly into the three holes on the opposite side of the blade. 2. Secure the flange assembly and flange medallion to the blade using the three M5 x 12mm pan head screws and three lockwashers.
7. Connect the 4-pin connector from the decorative light kit assembly to the 4-pin connector of the switch housing (Figure 3). 8. Connect the switch housing blue wire single-pin connector to the black.
22. 16” Or Optional Longer Downrod Installation: Slide the decorative scrolls over the 16” downrod to rest upon the decorative upper housing (Figure 9) To secure the decorative scrolls to the downrod, tighten the Philips head screw in the decorative scroll collar.
7 Ho w to Hang Y our Ceiling F an FLOOR CEILING A T LEAST 7' Figure 11 The fan must be hung with at least 7' of clearance from floor to blades (Figure 11). Do NOT hang this fan on an 8’ ceiling. WARNING 1. Securely attach the hanger bracket to the outlet box using the two screws supplied with the outlet box (Figure 12).
8 OUTLET BOX BLACK SUPPL Y WIRE BLACK/WHITE RECEIVER WIRE BLACK F AN WIRE BLUE F AN WIRE BLUE RECEIVER WIRE YELLOW F AN WIRE YELLOW RECEIVER WIRE CEILING COVER WHITE RECEIVER WIRE WHITE F AN WIRE WIRE.
1-1/4" THREADED STUD (2) CEILING COVER KNURLED KNOB (2) LOCKWASHER (2) HANGER BRACKET OUTLET BOX HANGER BALL/DOWNROD ASSEMBL Y 1-1/4" THREADED STUDS (2) HANGER BRACKET OUTLET BOX RECEIVER CE.
LIGHT KIT ASSEMBL Y LIGHT KIT SOCKET 50-WA TT (Max.) BI-PIN HALOGEN BULB (T ype GY8) 10 2. Place the glass onto the light kit assembly aligning the three flat areas on the top flange of the glass shade with the three pins on the inside of the assembly (Figure 19).
The SW116 wall control transmits the command signals via radio waves to the SW105 receiver installed in the ceiling fan ceiling cover. The SW105 receiver is required for the SW116 wall control to function. Power for the SW116 wall control comes from the 12V battery, located in the wall control.
Operating Y our Ceiling F an IMPORT ANT Fan installation must be completed, including the installation of the fan blades, before testing of the remote control. Your SW116 Fan/Light Wall Control (Figure 24) has full control of your fan, lights, and airflow direction.
13 T r ouble Shooting TROUBLE PROBABLE CAUSE SUGGESTED REMEDY 1. Fan will not start. 1. Fuse or circuit breaker blown. 1. Check main and branch circuit fuses or circuit breakers. WARNING: Make sure main power is turned off. 2. Loose power line connections to the fan.
14 1 8 9 10 3 2 7 5 17 31 18 19 4 6 21 11 24 23 12 22 26 27 28 15 16 30 25 14 29 H I H I M E D M E D L O W L O W F A N O F F R E V R E V L I G H T 32 20 13 13 R epair P ar ts U.
15 R epair P ar ts Listing Key Model Numbers N o . Description CF3100AGW00 CF3100BZH00 * Hanger Pack, Consisting of: 761655-71 761655-70 1 Hanger Bracket — — 2 Hanger Ball — — 3 Downrod - 16.
Air Comfort Products DIVISION OF EMERSON ELECTRIC CO. 8100 W. Florissant • St. Louis, MO 63136 Printed in China 01/08 Form No. BP7361 Part No. F40BP73610000 U.L. Model No.: CF3100 LIMITED WARRANTY What The Warranty Covers: This warranty covers the motor and the other components and accessories of your Emerson Electric Co.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Emerson CF3100AGW00 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Emerson CF3100AGW00 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Emerson CF3100AGW00 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Emerson CF3100AGW00 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Emerson CF3100AGW00, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Emerson CF3100AGW00.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Emerson CF3100AGW00. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Emerson CF3100AGW00 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.