READ AND SA VE THESE INSTRUCTIONS Part No. F40BP73370000 Form No. BP7337 U.L. Model No.: CF2455 Model No. CF2455BS00 CF2455ORB00 CF2455PW00 ODYSSEY ® Net W eight: 26.
2 W ARNING ! WARNING: To avoid fire, shock, and serious personal injury, follow these instructions. Safety Instructions 1. Read your owner’s manual carefully and keep it for future reference 2 .
7. Seven wire connectors 8. Three 8-32 x 3/8" phillips head screws 9. One hairpin clip 10. One clevis pin 11. Two knurled knob screws 1 2 . Twenty-one 10-32 x 3/8" pan head screws 13. One jumper assembly NOTE: Place the parts from the loose parts bags in small containers to keep them from being lost.
1. Position the fan motor and housing assembly in the lower styrofoam packing so that the top for the motor is facing you. 2. Obtain the hanger ball/downrod assembly and remove the hanger ball by loosening the setscrew in the hanger ball until the ball falls freely down the downrod (Figure 1).
5 6. Align the clevis pin holes in the downrod with the holes in the motor coupling. Install the clevis pin and secure with the hairpin clip (Figure 2).
6 12. Position the center styrofoam section on the upper section, and then position the fan motor and housing on the center section so that the bottom of the motor is facing you (Figure 5). The styrofoam sections will hold the assembly while you perform the following steps.
7 The outlet box and joist must be securely mounted and capable of supporting at least 50 lbs. Use only a U.L. outlet box listed as “Acceptable for Fan Support”. W ARNING ! Hanger bracket must seat firmly against outlet box. If the outlet box is recessed, remove wall board until bracket contacts box.
OUTLET BOX BLACK SUPPL Y WIRE BLACK/WHITE RECEIVER WIRE BLACK F AN WIRE BLUE F AN WIRE BLUE RECEIVER WIRE YELLOW F AN WIRE YELLOW RECEIVER WIRE CEILING COVER WHITE RECEIVER WIRE WHITE F AN WIRE WIRE C.
9 1-1/4" THREADED STUDS (2) HANGER BRACKET OUTLET BOX RECEIVER CEILING COVER Figure 16 BLUE RECEIVER WIRE YELLOW RECEIVER WIRE BLUE F AN WIRE DOWNROD BLACK F AN WIRE SW105 RECEIVER WHITE F AN WIR.
5. Obtain the die cast glass holders and light kit glass from the protective bags. 6. Position the light kit glass carefully on a convenient surface with the open side face down. 7. Remove the protective cover from the adhesive backed material on the glass holders (Figure 18).
The SW116 wall control transmits the command signals via radio waves to the SW105 receiver installed in the ceiling fan ceiling cover. The SW105 receiver is required for the SW116 wall control to function. Power for the SW116 wall control comes from the 12V battery, located in the wall control.
Operating Y our Ceiling Fan IMPORT ANT Fan installation must be completed, including the installation of the fan blades, before testing of the remote control. Your SW116 Fan/Light Wall Control (Figure 25) has full control of your fan, lights, and airflow direction.
13 T r ouble Shooting TROUBLE PROBABLE CAUSE SUGGESTED REMEDY 1. Fan will not start. 1. Fuse or circuit breaker blown. 1. Check main and branch circuit fuses or circuit breakers. WARNING: Make sure main power is turned off. 2. Loose power line connections to the fan.
14 4 2 1 3 5 6 7 10 3 11 25 8 7 31 30 29 15 15 20 21 22 23 24 28 27 12 13 14 8 26 9 HI MED LOW FAN OFF REV EMERSON D/L U/L 17 16 18 17 19 Repair Par ts.
15 Repair Par ts Listing Key Model No. N o . Description CF2455BS00 CF2455ORB00 CF2455PW00 1 Bracket Assembly, Hanger 760732 760732 760732 2 Hanger ball/downrod Assembly 761632-17 761632-37 761632-23 .
Air Comfort Products DIVISION OF EMERSON ELECTRIC CO. 8100 W. Florissant ¥ St. Louis, MO 63136 Printed in China 11/06 Part No. F40BP73370000 Form No. BP7337 LIMITED W ARRANTY What The Warranty Covers: This warranty covers the motor and the other components and accessories of your Emerson Electric Co.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Emerson CF2455BS00 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Emerson CF2455BS00 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Emerson CF2455BS00 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Emerson CF2455BS00 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Emerson CF2455BS00, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Emerson CF2455BS00.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Emerson CF2455BS00. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Emerson CF2455BS00 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.