Manuale d’uso / di manutenzione del prodotto CF2300S01 del fabbricante Emerson
Vai alla pagina of 16
READ AND SA VE THESE INSTRUCTIONS “Provence” Series Model No. CF2300TG01 CF2300S01 CF2300OB01 CF2300WB01 Pr ovence Series Ceiling Fan Owner's Manual Part No.
WARNING: To avoid fire, shock, and serious personal injury, follow these instructions. Safety Instructions 1. Read your owner’s manual carefully and keep it for future reference. 2 . Before servicing or cleaning unit, switch power off at service panel and lock service panel disconnecting means to prevent power from being switched on accidentally.
1. Open styrofoam unit containing fan. Remove top half of styrofoam unit. Remove parts and check to see that you have received the following: a. Fan motor and housing assembly b. One motor cover c. One ceiling cover d. Five blade flanges e. One hanger ball/downrod assembly f.
Your new ceiling fan will require a grounded electrical supply line of 120 volts AC, 60 Hz, 15 amp circuit. The outlet box must be securely anchored and capa- ble of withstanding a load of at least 50 pounds. If you feel that you do not have enough electrical wiring knowledge or experience, have your fan installed by a licensed electrician.
NOTE: Make sure the unused black motor lead is capped with a wire connector. Make sure all wire connectors are completely inside motor coupling cover and not pinched between the motor coupling cover and motor. 9. Screw two 1” threaded studs (supplied) into the motor (Figure 6).
15. Securely attach the hanger bracket to the outlet box using the two screws supplied with the outlet box (Figure 11). 6 11. Reinstall the hanger ball on the downrod as follows. Route the motor leads through the hanger ball and slide the hanger ball over the downrod (Figure 7).
7 TWO SCREWS SUPPLIED WITH OUTLET BOX HANGER BRACKET TA B OUTLET BOX OUTLET BOX HANGER BRACKET HANGER BALL/ DOWNROD ASSEMBL Y NOTE: CEILING COVER, SUPPL Y WIRES AND F AN WIRES OMITTED FOR CLARITY .
9. Install the setscrew (supplied in loose parts bag) in the motor coupling and tighten using the 5/32" setscrew wrench (supplied) (Figure 17). 10. Screw two 1” threaded studs (provided) into the motor (Figure 22). Leave approximately 7/8” of the stud extending above the motor.
14. Use three 10-32 x 3/8" pan head screws and flat washers (supplied) to secure flange to blade (Figure 20). Repeat for the remaining four blades. 15. Use the 10 round recessed holes in the motor hub marked with "5" and install the five blade assemblies (ordered separately) in accordance with Step 16.
17. Securely attach the hanger bracket to the outlet box using the two screws supplied with the outlet box (Figure 23). 18. Carefully lift the fan and seat the hanger ball/downrod assembly on the hanger bracket that was just attached to the outlet box (Figure 24).
Using Y our Ceiling Fan 1. Restore electrical power to the outlet box by turning the electricity on at the main fuse box. 2. When controlled by a wall switch check the opera- tion of the fan by gently pulling on the 4-position speed control pull chain switch.
T r ouble Shooting TROUBLE PROBABLE CAUSE SUGGESTED REMEDY 1. Fan will not start. 1. Fuse or circuit breaker blown. 1. Check main and branch circuit fuses or circuit breakers. WARNING: Make sure main power is turned off. 2. Loose power line connections to the fan, 2.
7 1 2 14 15 3 18 16 17 19 26 24 10 27 20 12 11 31 21 22 9 8 5 4 30 23 32 6 34 13 18 28 29 25 33 35 Repair Par ts 13 ACCESSORIES 1. Ceiling Fan Light Kits (see store or catalog). 2. Ceiling Fan/Light Controls (see store or catalog). 3. Downrod Extension Kits (see store or catalog).
14 Repair Par ts List Ref. Provence Models N o. Description CF2300S01 CF2300OB01 CF2300WB01 CF2300TG01 Hanger Pack, 761655-16 761655-9 761655-19 761655-13 containing: 1 Bracket, Hanger (1) — — —.
15 LIMITED W ARRANTY What The Warranty Covers: This warranty covers the motor and the other components and accessories of your Emerson ceiling fan against all defects in workmanship and materials. You must be the original purchaser or user of the product to be covered.
Part No. F40BP72170001 Printed in Taiwan 04/03 Form No BP7217-1 Air Comfort Products DIVISION OF EMERSON COMPANY 8100 W. Florissant ¥ St. Louis, MO 63136.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Emerson CF2300S01 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Emerson CF2300S01 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Emerson CF2300S01 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Emerson CF2300S01 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Emerson CF2300S01, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Emerson CF2300S01.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Emerson CF2300S01. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Emerson CF2300S01 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.