Part No. F40BP74070000 Form No. BP7407 UL Model No.: CF144 & CF152 READ AND SA VE THESE INSTRUCTIONS CUR V A SKY ™ 44” & 52” Damp & W et Loca tion Snugger Ceiling F an Owner's M.
WARNING: T o avoid fire, shock, and serious personal injury , follow these instructions. Safety Instructions 1. Read your owner ’ s manual carefully and keep it for future reference.
3 THE F AN MODELS CF144BS, CF144CRM, CF152BS & CF152CRM ARE SUIT ABLE FOR DAMP LOCA TIONS SUCH AS COVERED PORCHES, COVERED P A TIOS, AND COVERED DECKS...ANYWHERE THERE IS A ROOF OVERHEAD. THE F AN MODELS CF144WW , CF144ORB, CF152WW & CF152ORB ARE SUIT ABLE FOR WET LOCA TIONS SUCH AS PORCHES, P A TIOS, AND DECKS.
4 2. Remove the fan motor assembly from the protective plastic bag. Place all carton contents on a protective surface. B. CEILING TRIM RING D. F AN BLADES (3) G. GLASS SHADE A. F AN MOTOR ASSEMBL Y H. NO-LIGHT COVER PLA TE E. LOWER HOUSING K. 50W MINI CANDELABRA HALOGEN BULBS L.
5 Y our new ceiling fan will require a grounded electrical supply line of 120 volts AC, 60 Hz, 15 amp circuit. The outlet box must be securely anchored and capable of withstanding a load of at least 50 pounds.
CEILING FLOOR AT LEAST 7' Figure 5 6 UL Model No.: CF144 & CF152 9. T uck the wires and connectors into the fan housing. Position the light kit plate into the fan housing by placing the cut out notches over the fan housing dimples (Figure 4).
7 UL Model No.: CF144 & CF152 2. Pull the electrical supply black, white and ground wires through the center opening of the ceiling mounting plate before securing the plate to the outlet box (Figure 6). 3. Position the ceiling mounting plate onto the outlet box and secure using the two outlet box screws, supplied with outlet box (Figure 6).
UL Model No.: CF144 & CF152 3. After connections have been made, turn leads upward and carefully push leads into the outlet box, with the white and green leads on one side of the outlet box and the black and blue leads on the other inside of the outlet box.
1. Screw in two 50-watt (maximum) halogen mini candelabra base bulbs in the light kit plate sockets (Figure 13). 50-WA TT (maximum) HALOGEN MINI CANDELABRA BASE BULBS (2) LIGHT KIT PLA TE SOCKETS (2) Figure 13 2.
10 UL Model No.: CF144 & CF152 General Y our Emerson Ceiling Fan/Light Remote Control consists of hand-held transmitter and a receiver which is mounted under the fan ceiling cover . The remote control is designed to separately control your ceiling fan speed and light intensity .
11 UL Model No.: CF144 & CF152 Setting Operating F r equency of R emote Control 1. Slide the five switch levers in the remote control to your choice of ON (up) or down positions. Use a ball-point pen or small screwdriver and slide the levers firmly up or down.
UL Model No.: CF144 & CF152 12 INSTRUCTION TO THE USER (if device contains a digital device) This equipment has been tested and found to comply with the limits for a class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
UL Model No.: CF144 & CF152 13 Fan/Light Fails to Operate • Check that the speed switch on the fan is set to HIGH ( .... ) speed. • Check that the light switch is on. • Check that the battery is good (red indicator light should light when any button is pressed).
14 UL Model No.: CF144 & CF152 Damp Part Numbers Wet Part Numbers Key Model No. Model No. Model No. Model No. Model No. Model No. Model No. Model No.
15 UL Model No.: CF144 & CF152 R epair Par ts 2 3 15 8 - 52" 9 - 44" 1 14 4 5 6 5 10 16 13 17 12 11 Before discarding packaging material, be certain all parts have been removed.
LIMITED WARRANTY What The W ar ranty Covers: This warranty covers the motor and the other components and accessories of your Emerson ceiling fan against all defects in workmanship and materials. Y ou must be the original purchaser or user of the product to be covered.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Emerson CF144ORB00 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Emerson CF144ORB00 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Emerson CF144ORB00 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Emerson CF144ORB00 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Emerson CF144ORB00, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Emerson CF144ORB00.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Emerson CF144ORB00. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Emerson CF144ORB00 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.