Gas V alve Cross Reference 1 36 C White-Rodgers is the leading manufacturer of gas valves to the OEM. When it’s time to replace – replace with the same brand trusted by OEMs on their equipment! Complete online Cross Reference for White-Rodgers and competitive gas valves www .
2 Gas V alve Cross Reference Index Gas V alve Selection Guide ................................................. 3 Range of Operation ............................................................ 5 Nomenclature ..........................................
Gas V alve Cross Reference 3 ► Gas V alve Selection Guide What questions need to be asked when matching up gas valves? 1. T ype of V alve 1.1 Standing Pilot 1.2 Intermittent Ignition (Proven/Intermittent Pilot) 1.3 Direct Burner Ignition (Spark or Hot Surface) 1.
4 Gas V alve Cross Reference Millivolt Na t. L. P. 36 C0 4U -438 Re du ce r bu sh in gs ar e in cl ud ed OP EN IN G SL OW OP EN IN G 24V ac Na t. L. P. 36C53- 41 8 FA ST L. P. 24 Va c Mi lli vo lt 12 0V ac 36 C0 3U -4 33 36 C0 3-43 33 6C03 A- 41 0 Al l re du ce r bu sh in gs an d co nv er si on ki ts ar e in cl ud ed ST EP OP EN IN G L.
Gas V alve Cross Reference 5 ► Range of Operation 36C 36H 36J Applications Natural Gas Range of Regulation Opening Characteristic Fast Open Slow Open Step Open Fast Open Slow Open 2-Stage Fast Open .
6 Gas V alve Cross Reference 36C XX X - XXX Basi c M odel Number Series S pecification of options/features ( numbered versions ) VO LTA GE LETTE R CODING LETTE RV O LTA GE FREQUENCY CURRENT NONE A B C.
Gas V alve Cross Reference 7 Model Number 36H22 36H23 36H32 36H33 36H54 36H55 36H64 36H65 Fast Open Slow Open Direct Ignition Proven Pilot Single Stage T wo Stage FE AT URE S X X X X X X X X X X X X X.
8 Gas V alve Cross Reference Hot Surface Ignition (HSI) The thermostat calls for heat and energizes the HSI control. If system is equipped with prepurge, the purge fan is energized and power will be delayed thirty seconds before application to the Hot Surface Ignitor .
Gas V alve Cross Reference 9 Standing Pilot Gas ow to the pilot burner is controlled by a safety valve which is manually operated and held in by current generated from a thermocouple placed in the pilot ame. When the thermostat calls for heat the main valve is energized.
10 Gas V alve Cross Reference Cycle Pilot System The thermostat calls for heat and simultaneously energizes pilot solenoid and pilot relight control. Pilot valve opens and relight begins sparking. Gas ow activates the pressure switch. Sparks ignite pilot gas.
Gas V alve Cross Reference 11 36C Series Combination Gas V alve. The versatile 36C03 Series combination gas valves cover a wide range of applications. Designed for use with common ignition systems and standing pilots, it replaces hundreds of existing models in the eld.
12 Gas V alve Cross Reference 36H Series Universal Replacement Electronic Ignition Gas V alve. The versatile 36H Series combination gas valves cover a wide range of applications. Designed for use with common ignition systems (HSI/DSI/Proven Pilot), it replaces hundreds of existing models in the eld.
Gas V alve Cross Reference 13 36J Series Replacement Electronic Ignition Gas V alve. The versatile 36J series combination gas valves cover a wide range of applica- tions. Designed for use with common ignition systems (HSI/DSI), it replaces hundreds of existing models in the eld.
14 Gas V alve Cross Reference 36C Series 36H Series 36J Series ACCESSORIES Model Number Regulator Conversion Kits F92-0659 Natural Gas to LP Single Stage F92-1008 Natural Gas to LP T wo-Stage F92-0656.
Cross Reference OEM NO. WR NO. Gas V alve Cross Reference 15 OEM NO. WR NO. OEM NO. WR NO. ► Cross Reference 00 880208 36C03A-410 00 880209 36C03A-410 00001005570 36H32-304 00001008753 36J24-214 000.
Cross Reference OEM NO. WR NO. OEM NO. WR NO. OEM NO. WR NO. 16 Gas V alve Cross Reference ► Cross Reference 13005223 36H32-304 1300-5223 36J22-214 13006223 36J22-214 130280 36J24-214 1353473 36C84-.
Cross Reference OEM NO. WR NO. OEM NO. WR NO. OEM NO. WR NO. Gas V alve Cross Reference 17 ► Cross Reference 25G01-3 36C21-41 1 25G01-303 36C21-41 1 25G01-304 36C21-41 1 25G01-306 36C21-41 1 25G01-3.
Cross Reference OEM NO. WR NO. OEM NO. WR NO. OEM NO. WR NO. 18 Gas V alve Cross Reference ► Cross Reference 3661-588 36C03-333 3661-628 36C03-333 3661-688 36C03-333 3661-82 36C03-333 3661-83 36C03-.
Cross Reference OEM NO. WR NO. OEM NO. WR NO. OEM NO. WR NO. Gas V alve Cross Reference 19 ► Cross Reference 36C10A-209 36C03A-410 36C10A-276 36C03A-410 36C10A-300 36C03A-410 36C10A-400 36C03A-410 3.
Cross Reference OEM NO. WR NO. OEM NO. WR NO. OEM NO. WR NO. 20 Gas V alve Cross Reference ► Cross Reference 36C74-474 36C74-913 36C74-475 36C74-913 36C74-505 36C74-913 36C74-913 36C74-913 36C76-205.
Cross Reference OEM NO. WR NO. OEM NO. WR NO. OEM NO. WR NO. Gas V alve Cross Reference 21 ► Cross Reference 36E01-245 36H32-304 36E01-247 36H32-304 36E01-248 36H32-304 36E01-253 36H32-304 36E01-255.
Cross Reference OEM NO. WR NO. OEM NO. WR NO. OEM NO. WR NO. 22 Gas V alve Cross Reference ► Cross Reference 36E55-200 36J55-214 36E55-203 36J55-214 36E55-208 36J55-214 36E55-209 36J55-214 36E55-218.
Cross Reference OEM NO. WR NO. OEM NO. WR NO. OEM NO. WR NO. Gas V alve Cross Reference 23 ► Cross Reference 36H22-401 36H32-423 36H22-402 36H32-423 36H22-404 36H32-423 36H22-406 36H32-423 36H22-407.
Cross Reference OEM NO. WR NO. OEM NO. WR NO. OEM NO. WR NO. 24 Gas V alve Cross Reference ► Cross Reference 5H3207B1 36H32-423 5H4052 B2 36C03-433 5H73017B0002 36H64-463 5H73122B1 36C03-433 5H73122.
Cross Reference OEM NO. WR NO. OEM NO. WR NO. OEM NO. WR NO. Gas V alve Cross Reference 25 ► Cross Reference B67RB00000000 36C03U-333 B67RB141 36C03U-333 B67RF00000000 36C03U-433 B67RF45 36C03U-433 .
Cross Reference OEM NO. WR NO. OEM NO. WR NO. OEM NO. WR NO. 26 Gas V alve Cross Reference ► Cross Reference V AL04395 36C03A-410 V AL04921 36C03-300 V AL04922 36C03-333 V AL04923 36C03-400 V AL0492.
Cross Reference OEM NO. WR NO. OEM NO. WR NO. OEM NO. WR NO. Gas V alve Cross Reference 27 ► Cross Reference VS8179A1283 36C03U-333 VS8179A1291 36C03U-333 VS8179A1309 36C03U-333 VS8179A1317 36C03U-3.
Cross Reference OEM NO. WR NO. OEM NO. WR NO. OEM NO. WR NO. ► Cross Reference VS820B1037 36C03U-433 VS820B1045 36C03U-433 VS820B1078 36C03U-333 VS820B1086 36C03U-433 VS820B1 102 36C03U-433 VS820C10.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Emerson 36J è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Emerson 36J - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Emerson 36J imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Emerson 36J ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Emerson 36J, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Emerson 36J.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Emerson 36J. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Emerson 36J insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.