Manuale d’uso / di manutenzione del prodotto 1F97-1277 del fabbricante Emerson
Vai alla pagina of 12
Big Blue T ouchscreen T her mostat with Automa tic Heat/Cool Changeo ver Option Installation and Operating Instructions for Model: APPLICA TIONS 1F97-1277 T ouchscreen Thermostat SPECIFICA TIONS Electrical Rating: Battery Power .......................
2 2 "AA" Batteries WIRING CONNECTIONS Refer to equipment manufacturers' instructions for specic system wiring information. After wiring, see CONFIGURA- TION section for proper thermostat conguration. For wiring diagrams, see next page.
3 Single Stage Connections Refer to equipment manufacturers' instructions for specic system wiring information. This thermostat is designed to operate a single-transformer or two- transformer system. Y ou can congure the thermostat for use with the following systems: SINGLE ST AGE gas, oil or electric.
4 1 Displays and "Keypad Lockout" when in keypad lockout mode. Displays and "T emperature Limit" and "Keypad Lockout" when limited range is activated and locked. Displays only "T emperature Limit" when limited range is activated.
5 T o enter the menu: Press the Menu touch key . Press and hold for 5 seconds the Installer Cong touch key . This displays menu item #1 in the table below . Press to advance to the next menu item or to return to a previous menu item. Press or to change a menu item.
6 the backlight on continuously . Selecting dL Of f will turn the backlight on momentarily after any key is pressed. When C terminal is not powered (battery only), dL On enables the momentary backlight whenever a key is pressed.
7 INST ALLER/CONFIGURA TION MENU 20) Heat T emperature Limit Range – This feature adjusts the highest setpoint temperature for heat. The default setting is 99°F .
8 OPERA TING YOUR THERMOST A T Choose the Fan Setting (Auto or On) Fan Auto is the most commonly selected setting and runs the fan only when the heating or cooling system is on. Fan On selection runs the fan continuously for increased air circulation or to allow additional air cleaning.
9 PROGRAMMING Fill in the blank schedule on the next page then: Enter the Heating Program 1) Press the Menu button and then press Set Schedule. Press SYSTEM button to select either "Heat" or "Cool" in the system switch area indicating the active mode being programmed.
10 PROGRAMMING Energy Saving Factory Pre-Program The 1F97-1277 thermostats are programmed with the energy saving settings shown in the table below for all days of the week. If this program suits your needs, simply set the thermostat clock and press the RUN button.
11 Wired Remote T emperature Sensing One remote temperature sensor can be installed indoor or outdoor and connected to the thermostat by a maximum cable length of 100 meters (300 ft). Three terminals, +, S & - are provided on the terminal block to connect to the White- Rodgers standard wired remote sensor .
www .white-rodger s.com www .emersonc limate.com TROUBLESHOOTING Reset Operation Note: When thermostat is reset, installer conguration menu settings and programming will reset to factory settings.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Emerson 1F97-1277 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Emerson 1F97-1277 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Emerson 1F97-1277 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Emerson 1F97-1277 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Emerson 1F97-1277, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Emerson 1F97-1277.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Emerson 1F97-1277. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Emerson 1F97-1277 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.