UST Universal Slim Twin Model Number 16C26S-010 OWNERS MANUAL • Installation • Operation • Basic UST Service Guide • T echnical Repair Guide • Repair Parts Part No. 37-6070A Replaces 846-2027 Rev B 0015 Electronic Air Cleaner Printed In U.S.
2 RULES FOR SAFE INST ALLA TION AND OPERA TION Please read instructions before installing and using the Electronic Air Cleaner. This will help you obtain the full benefit from the Electronic Air Cleaner you have selected. WARNING ! ELECTROCUTION HAZARD Shut off power at fuse panel before servicing.
3 HOW THE AIR CLEANER WORKS Dirt particles flowing through the ducts (Figure 1) first enters the pre-filters (A) where large particles (hair, lint, etc.) are trapped. Smaller particles (smoke, dust, pollen, etc.) pass through these pre-filters and enter the ionizing section (B).
4 PREINST ALLA TION facing the power door. Air flow direction must agree with arrow embossed on end of collecting cells. After installing the cell sections, install pre-filters in cabi- net tracks on the right. This will again place the pre-filters on the air entering side (on the same side as ionizing wires).
5 TYPICAL MOUNTING POSITIONS BASEMENT FURNACE (LOWBOY) (Figure 6) Cleaner is mounted hori- zontally in return plenum, just above furnace. COUNTERFLOW FURNACE (Figure 7) Cleaner is mounted horizon- tally in return duct or plenum, just above furnace. HIGHBOY FURNACE (Figure 8) Side installation.
6 INST ALLA TION REMOVE OLD FILTER AND DISCARD (Figure 12) NOTE: This filter may be mounted in the furnace compart- ment. CLEAN BLOWER COMPARTMENT It is suggested that the furnace blower compartment, blower and blower housing be cleaned to ensure clean air circulation.
7 WIRING INSTRUCTIONS 7. With the cabinet installed, the air cleaner can now be wired to electrical input source. WARNING ! Installation of this unit must comply with local electric codes or other applicable codes. Review and understand local codes prior to in- stallation.
8 An alternate method for controlling the air cleaner operation is to install an F859-0381 Air Flow Switch/ Harness Kit (available separately) that switches power to the air cleaner when airflow is detected. NOTE: The air cleaner should not be operating un- less the furnace blower is on.
9 3. Release the latch on top of power pack and pull the power pack straight away from cabinet at the top. Then lift pack out of ledge at bottom edge of cabinet. Set power pack aside. 4. Remove the cell(s) and pre-filter(s) from cabinet. Using a solution of warm water and low sudsing detergent, soak cell(s) and pre-filter(s) for 20 to 30 minutes.
10 SERVICE INDICA TION SER VICE CHECKS ON/OFF switch “ON” Unit functioning Normally Blower ON Operating Light ON ON/OFF switch “ON” 1. Power is not being supplied to air cleaner . Blower ON A. Check fuse or circuit breaker . Operating Light OFF B.
11 TECHNICAL REP AIR GUIDE All voltage measurements indicated can be made with a high voltage D.C. probe and a general purpose volt ohm meter. For example: Simpson 260 or equivalent. NOTE: All tests to be performed with the Ozone Reduc- tion Jumper intact.
12 POWER SUPPLY CHECKOUT PROCEDURE 1. Turn power switch to the “OFF” position and remove the power pack from cabinet. 2. Place power pack on a well insulated workbench. Connect meter negative (-) lead to the sheet metal chassis and the high voltage probe to high voltage contact on back cover of power pack.
13 NOTES.
14 REP AIR P AR TS.
15 ITEM NO. DESCRIPTION P ART NUMBER 16C28S-010 1 Cabinet N/A 2 Pre-Filter • F825-0337 3 Collecting Cell • F81 1-0321 4 Junction Box Cover F838-0072 5 * Screw #6 x 3/8 ------ 6 Connector , Female .
White-Rodgers Division, Emerson Electric Co. 9797 Reavis Road, St. Louis, MO 63 123-5398 314-577-1300 • FAX 314-577-1517 www.white-rodgers.com Controlling America’s Indoor Comfort NOTICE T O CONSU.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Emerson 16C26S-010 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Emerson 16C26S-010 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Emerson 16C26S-010 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Emerson 16C26S-010 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Emerson 16C26S-010, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Emerson 16C26S-010.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Emerson 16C26S-010. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Emerson 16C26S-010 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.