Design Guide & Applications Manual For VI-200 and VI-J00 Family DC-DC Converters and Configurable Power Supplies vicorpower .com 800-735-6200 Applications Engineering 1- 800-927-9474 Rev . 2.1 Page 18 of 88 +IN GA TE IN GA TE OUT –IN +OUT +S TRIM –S –OUT C2 C1 C2 C3 C3 C1 = 100 μ F C2 = 4,700 pF C3 = 0.
Design Guide & Applications Manual For VI-200 and VI-J00 Family DC-DC Converters and Configurable Power Supplies vicorpower .com 800-735-6200 Applications Engineering 1- 800-927-9474 Rev . 2.1 Page 19 of 88 9. EMC Considerations Common-Mode Noise with Common-Mode Choke.
Design Guide & Applications Manual For VI-200 and VI-J00 Family DC-DC Converters and Configurable Power Supplies vicorpower .com 800-735-6200 Applications Engineering 1- 800-927-9474 Rev . 2.1 Page 20 of 88 9. EMC Considerations L1 C4 C1 = 100 μ F C2 a – C2 b = 4,700 pF (Vicor Part # 01000) C3 a – C3 b = 0.
Design Guide & Applications Manual For VI-200 and VI-J00 Family DC-DC Converters and Configurable Power Supplies vicorpower .com 800-735-6200 Applications Engineering 1- 800-927-9474 Rev . 2.1 Page 21 of 88 9. EMC Considerations Differential and Common-Mode Filter with More than One Module .
Design Guide & Applications Manual For VI-200 and VI-J00 Family DC-DC Converters and Configurable Power Supplies vicorpower .com 800-735-6200 Applications Engineering 1- 800-927-9474 Rev . 2.1 Page 22 of 88 3 Amp Load 15 Amp Load 30 Amp Load 9. EMC Considerations Differential-Mode Noise Filter .
Design Guide & Applications Manual For VI-200 and VI-J00 Family DC-DC Converters and Configurable Power Supplies vicorpower .com 800-735-6200 Applications Engineering 1- 800-927-9474 Rev . 2.1 Page 23 of 88 9. EMC Considerations RADIA TED NOISE Radiated noise may be either electric field or magnetic field.
Design Guide & Applications Manual For VI-200 and VI-J00 Family DC-DC Converters and Configurable Power Supplies vicorpower .com 800-735-6200 Applications Engineering 1- 800-927-9474 Rev .
Design Guide & Applications Manual For VI-200 and VI-J00 Family DC-DC Converters and Configurable Power Supplies vicorpower .com 800-735-6200 Applications Engineering 1- 800-927-9474 Rev . 2.1 Page 25 of 88 9. EMC Considerations No Additional Filter 2% p-p (T ypical) 1% p-p (T ypical) 0.
Design Guide & Applications Manual For VI-200 and VI-J00 Family DC-DC Converters and Configurable Power Supplies vicorpower .com 800-735-6200 Applications Engineering 1- 800-927-9474 Rev . 2.1 Page 26 of 88 9. EMC Considerations NOTE : A low ESR capacitor should be used on the output, preferably tantalum.
Design Guide & Applications Manual For VI-200 and VI-J00 Family DC-DC Converters and Configurable Power Supplies vicorpower .com 800-735-6200 Applications Engineering 1- 800-927-9474 Rev . 2.1 Page 27 of 88 9. EMC Considerations C1 = 100 µF C2 a – C2 b = 4,700 pF (Vicor P ar t # 01000) C3 a – C3 b = 0.
Design Guide & Applications Manual For VI-200 and VI-J00 Family DC-DC Converters and Configurable Power Supplies vicorpower .com 800-735-6200 Applications Engineering 1- 800-927-9474 Rev . 2.1 Page 28 of 88 9. EMC Considerations RAM / MI-RAM OPERA TION The RAM / MI-RAM attenuates output noise in two ways.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il EMC VI-200 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del EMC VI-200 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso EMC VI-200 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul EMC VI-200 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il EMC VI-200, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del EMC VI-200.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il EMC VI-200. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo EMC VI-200 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.