Manuale d’uso / di manutenzione del prodotto ED-12000B del fabbricante EMC
Vai alla pagina of 574
EMC Corporation 171 South Stree t Hopkinto n, MA 01748- 9103 Cor porate Headquarter s : (508) 435-1000 , (800) 424-EMC2 Fa x : (508) 435- 5374 Ser vice : (800) SVC -4EMC EMC Connectrix Departmental Switch DS-32B2 and Enterprise Dire ctor ED-12 000B Fabric OS Version 4.
EMC Connectr ix DS-32B2 and ED -12000B Fabr ic OS Reference Manual ii Copyright © 2000 - 2002 EMC Corporation. All rights re served. Printe d Novemb er, 2002 EMC bel ieves the information in this pu blication is accu rate as of its public ation dat e.
EMC Con nectrix DS-32B 2 and ED-1200 0B Fabric OS Reference Manual iii This equipmen t generates, us es, and may emit ra dio frequency energy. The equipm ent has be en type tested and found to comply .
EMC Connectr ix DS-32B2 and ED -12000B Fabr ic OS Reference Manual iv.
EMC Con nectrix DS-32B 2 and ED-1200 0B Fabric OS Reference Manual v Preface ........................ ........... ................. ........... ................. ........... ............ ................ ... xiii Chapter 1 T elnet Co mmands agtcfgDefault .
EMC Connectr ix DS-32B2 and ED -12000B Fabr ic OS Reference Manual vi Contents cfgEnable ........... ................. ........... ................. ........... ................. ..... 1-60 cfgRemove .. ................. ........... ................. .
vii EMC Con nectrix DS-32B 2 and ED-1200 0B Fabric OS Reference Manual Conte nts fabricShow ............ ........... ................. ............ ................. ........... .... 1 -144 fabStatsShow ................... ................. ..........
EMC Connectr ix DS-32B2 and ED -12000B Fabr ic OS Reference Manual viii Contents iodShow . ................ ............ ................. ........... ................. ........... ... 1-220 ipAddrSet ............... ............ ................. ...
ix EMC Con nectrix DS-32B 2 and ED-1200 0B Fabric OS Reference Manual Conte nts perfCfgSave ..................... ................. ............ ........... ................. .... 1 -292 perfClrAlpaCr c .......... ................. ........... .......
EMC Connectr ix DS-32B2 and ED -12000B Fabr ic OS Reference Manual x Contents qloopRemove.... ........... ................. ........... ................. ............ ........ 1-381 qloopShow ................... ................. ........... .........
xi EMC Con nectrix DS-32B 2 and ED-1200 0B Fabric OS Reference Manual Conte nts syslogdIpShow ........................... ........... ........... ................. .......... 1-455 systemtest ....... ................. ............ ................. ..
EMC Connectr ix DS-32B2 and ED -12000B Fabr ic OS Reference Manual xii Contents Chapter 5 Cont ro l Pr oces sor Co mmands Active CP Commands ....................... ........... ................. ........... ....... 5-2 Standby CP Commands ............
EMC Con nectrix DS-32B 2 and ED-1200 0B Fabric OS Reference Manual xiii Preface As part o f its effo rt to continu ousl y improve and e nhan ce the pe rforman ce and capabilities of the EMC product line, EMC period ically releases new versio ns of the E MC Con nectri x Depart mental Switch DS-32B 2 and Enterprise Director ED-12000B Fabr ic OS.
xiv EMC Connectr ix DS-32B2 and ED-12000B Fabric O S Ref erence Ma nual Preface Chapter 3, Fabric OS V ersion Co mparison , summarizes the commands avail abl e in v3.0 and v4.0 . Chapter 4, Fabric and Switch Man agement , explains the differ ent method s used to ma nage a SA N for DS-32B2 an d ED-1200 0B switches .
EMC Con nectrix DS-32B 2 and ED-1200 0B Fabric OS Reference Manual xv Preface Conv entions Used in this Guide EMC uses the following conventions for notes, cautions, warnings, and danger n otices. A no te pr esent s inf ormat ion th at is im portan t, b ut not haza rd -re lated.
xvi EMC Connectrix D S-32B2 and ED-12000B Fabric O S Ref erence Ma nual Preface Where to Get Help Obtain technica l support by callin g your local sales o ffice. For service, call: and as k for Custo mer S uppo rt. If you ar e located outside the USA, call the near est EMC off ice for technical assistance.
Te l n e t C o m ma n d s 1-1 1 Invisible Body T ag This chapter desc ribes the followin g commands : ◆ agtcfgDefault ......... ........... ................. ............ ................. ........... ......... 1-8 ◆ agtcfgSet ...... .............
1 1-2 EMC Connectr ix DS-32B2 and ED-12000B Fabric O S Ref erence Manual T elnet Commands ◆ cfgRemove ........ ........... ................. ............ ................. ........... ............ 1-61 ◆ cfgSave ............... ................. .
1 1-3 T elnet Com mands ◆ fabStatsShow ... ................. ............ ................. ........... ........... ........... 1- 146 ◆ fanDisable ........ ................. ............ ........... ................. ........... ........... 1- 147 ◆ fanEnable .
1 1-4 EMC Connectr ix DS-32B2 and ED-12000B Fabric O S Ref erence Manual T elnet Commands ◆ ipAddrSet ..................... ............ ................. ........... ................. .......... 1-221 ◆ ipAddrShow ........... ........... ........
1 1-5 T elnet Com mands ◆ perfClrAlpaCr c ............................ ........... ................. ........... ........... 1-29 3 ◆ perfDelEEMonitor ....................... ........... ................. ........... ........... 1-29 5 ◆ perfDelFilterMonitor .
1 1-6 EMC Connectr ix DS-32B2 and ED-12000B Fabric O S Ref erence Manual T elnet Commands ◆ qloopShow .. ................. ............ ................. ........... ................. .......... 1-383 ◆ ramT est .................... ..............
1 1-7 T elnet Com mands ◆ timeOut .................. ........... ................. ............ ................. ........... ..... 1-459 ◆ topologyShow ............. ................. ........... ................. ........... ........... 1-460 ◆ trackChangesSet.
1 1-8 EMC Connectr ix DS-32B2 and ED-12000B Fabric O S Ref erence Manual T elnet Commands agtcfgDef ault Reset the SNMP ag ent configuration to default value. Syntax agtcfgDefault A v ailability Admin Descr iption Use this com mand to reset the configuration of the SNM P agent to default values.
1 agtc fgDef a ult 1- 9 T elnet Com mands There are s ix communities and respective trap r ecipients supported by the agent. The first three communities are for r ead-write access (rw) and the last three are for r ead-only access (ro). Note that the factory default value for the trap re cipient of each community is "0.
1 1-10 EMC Connectr ix DS-32B2 and ED -12000B Fabr ic OS Reference Manual T elnet Commands Example T o set the SNMP agent conf iguration parameters to the default v alues , and verify the def ault va .
1 agtcfgSet 1-11 T elnet Com mands agtcfgSet Modify t he SNMP ag ent confi guratio n. Syntax agtcfgSet A v ailability Admin Descr iption Use this co mmand to mo dify the configura tion of the SNM P agent in the switch. Set the valu es for the following items.
1 1-12 EMC Connectr ix DS-32B2 and ED -12000B Fabr ic OS Reference Manual T elnet Commands There are s ix communities and respective trap r ecipients supported by the agent. The first thr ee communities are fo r read-w rite access (rw) and the last three are for r ead-only access (ro).
1 agtcfgSet 1-13 T elnet Com mands sysDescr: [FC Switch] sysLocation: [End User Premise] sysContact: [Field Support] swEventTrapLevel: (0..5) [0] 3 authTrapsEnabled (true, t, false, f ): [false] t SNMP community and trap recipient conf iguration: Community (rw): [Secret C0de] Trap Recipient’s IP address in dot notation: [192.
1 1-14 EMC Connectr ix DS-32B2 and ED -12000B Fabr ic OS Reference Manual T elnet Commands No trap recipient configured yet Community 3: private (rw) No trap recipient configured yet Community 4: publ.
1 agtcfgShow 1-15 T elnet Com mands agtcfgSho w Display th e SNMP agent configurat ion. Syntax agtcfgShow A v ailability All users Descr iption Use this com mand to display the conf iguration of the SNMP agen t in the switch. The followi ng inform ation is displayed: Ther e is one agent per logical swit ch.
1 1-16 EMC Connectr ix DS-32B2 and ED -12000B Fabr ic OS Reference Manual T elnet Commands The factory default value for the trap r ecipient of each community is "0.
1 agtcfgShow 1-17 T elnet Com mands Community 5: common (ro) No trap recipient configured yet Community 6: FibreChannel (ro) No trap recipient configured yet SNMP access list configuration: Entry 0: Access host subnet area 192. 168.64.0 (rw)] Entry 1: Access host subnet area 192.
1 1-18 EMC Connectr ix DS-32B2 and ED -12000B Fabr ic OS Reference Manual T elnet Commands aliasDelete Delete a port from all local groups. Syntax aliasDelete portID A v ailability Admin Descr iption Use th is co mman d to delete a local p ort f ro m al l loc al gr ou ps.
1 alia sJoin 1-19 T elnet Com mands aliasJoin Create o r add a member to a gr oup of N_Ports. Syntax aliasJoin A v ailability Admin Descr iption Use this command to cr eate an alias group of N_Ports or to add N_Ports to a n existing group. Any on line N_Port def ined in the fabric can be p art of a group .
1 1-20 EMC Connectr ix DS-32B2 and ED -12000B Fabr ic OS Reference Manual T elnet Commands See Als o aliasShow aliasDelete aliasPurge.
1 aliasP urge 1-21 T elnet Com mands aliasPurge Remove an alias group. Syntax aliasPurge groupID A v ailability Admin Descr iption Use this command t o remove an alias group.
1 1-22 EMC Connectr ix DS-32B2 and ED -12000B Fabr ic OS Reference Manual T elnet Commands aliasSho w Display alia s server informa tion. Syntax aliasShow A v ailability All users Descr iption Use this co mmand to display l ocal alias server inf ormation.
1 aliasShow 1-23 T elnet Com mands Example T o display the entries in the local alias ser ver: switch:admin> aliasShow Alias ID Creator Token [rb, type, grptype, qlfr] Member List fffb01 fffffd [00, 05, 10, 10000060 69 800228] { 019c00 } The Local Alias Server has 1 entry switch:admin> Exit Sta tus 0 Indicates successful operation.
1 1-24 EMC Connectr ix DS-32B2 and ED -12000B Fabr ic OS Reference Manual T elnet Commands aliAdd Add a me mber to a zone alia s. Syntax aliAdd aliName, member; member A v ailability Admin Descr iption Use this command to add o ne or more m embers to an existing zone alias.
1 aliCrea te 1-25 T elnet Com mands aliCreate Cr eate a zo ne alia s. Syntax aliCreate aliName, member; member A v ailability Admin Descr iption Use this command to cr eate a new zone alias. The zone alias member list must have a t least one member (empty lists are not a llowed).
1 1-26 EMC Connectr ix DS-32B2 and ED -12000B Fabr ic OS Reference Manual T elnet Commands Example T o add zone aliases usin g member names: switch:admin> aliCreate "array1", "32; 33.
1 aliDelete 1-27 T elnet Com mands aliDelete Delete a zone alia s. Syntax aliDelete aliName A v ailability Admin Descr iption Use this command to delete a zone alias. This command changes the defined configuration. For the change to become effective, an appr opriate zone configuration m ust be enabled using the cfgEnable command.
1 1-28 EMC Connectr ix DS-32B2 and ED -12000B Fabr ic OS Reference Manual T elnet Commands aliRemov e Remove a member fr om a zone alias. Syntax aliRemove aliName, member; member A v ailability Admin Descr iption Use this command to r emove one or mor e members fr om an existing zone alias.
1 aliRem ov e 1-29 T elnet Com mands Example T o remov e a member fr om array1: switch:admin> aliRemove "array1", "3,5 " switch:admin> aliRemove "array1", "21:.
1 1-30 EMC Connectr ix DS-32B2 and ED -12000B Fabr ic OS Reference Manual T elnet Commands aliShow Display z one alias in formation. Syntax aliShow " pattern" A v ailability All users Descr iption Use this com mand to displa y zone config uration inform ation.
1 aliShow 1-31 T elnet Com mands Example T o show all zone aliases beginning with arr: switch:admin> aliShow "arr*" alias: array1 21:00:00:20:37:0c:76:8c alias: array2 21:00:00:20:37:0c:6.
1 1-32 EMC Connectr ix DS-32B2 and ED -12000B Fabr ic OS Reference Manual T elnet Commands back planetest Run Backplane connection test f or multiple blade configur ed system.
1 bac kpl an ete st 1-33 T elnet Com mands -pat type Specify the test pattern type used in the test frame payload. The default test is 17(jCRP A T). The followin g test patterns can be s pecif ied: .
1 1-34 EMC Connectr ix DS-32B2 and ED -12000B Fabr ic OS Reference Manual T elnet Commands Example T o run a backplane connection t est: switch:admin> backplanetest -ports 2/1 6 2/18 2/20 -payload 2048 -verbo se 1 Running Backplane Conn Test .
1 backP or t 1-35 T elnet Com mands back P ort Run test f or back-e nd mini switch-t o-min iswitch li nks. Syntax backport [-nframes num ][-ports list ][- lb_mode mode ][-fr_type type ] [-extonly enable ] A v ailability Admin Descr iption Use this comma nd to test the backplan e routing and VC allocation.
1 1-36 EMC Connectr ix DS-32B2 and ED -12000B Fabr ic OS Reference Manual T elnet Commands -lb_mode mode Specify the loopback mode fo r source and destina tion st andard meanin gs.
1 backP or t 1-37 T elnet Com mands Example T o test for bac k-end miniswitch to miniswitch links: switch:admin> backport Running Backport Test ....
1 1-38 EMC Connectr ix DS-32B2 and ED -12000B Fabr ic OS Reference Manual T elnet Commands bcastsho w Display broadcast routing informat ion. Syntax bcastShow A v ailability All users Descr iption Use this com mand to displa y the broadcast routing informa tion for all ports in the s witch.
1 bcas tsh o w 1-39 T elnet Com mands See Al so mcastShow portRouteShow.
1 1-40 EMC Connectr ix DS-32B2 and ED -12000B Fabr ic OS Reference Manual T elnet Commands bladeBeacon Set blad e beac oning mod e on or off. Syntax bladeBeacon [ blade] mode A v ailability Admin Descr iption Use this co mmand to set t he blade beaconing mode on or o ff.
1 bladeBeacon 1-41 T elnet Com mands Example T o turn t he blade in slot 2 beaconing mode O n and then Off: switch:admin> bladeBeacon 2 1 See Al so switchShow.
1 1-42 EMC Connectr ix DS-32B2 and ED -12000B Fabr ic OS Reference Manual T elnet Commands bladeDiag Run dia gnosti cs on a sw itch blade. Syntax bladediag [[-slot] slot ] A v ailability Admin Descr iption Use this comma nd to run a suite of diagnostics tests on the specified switch blad e.
1 bladeDiag 1-43 T elnet Com mands Example T o r un a suite of diagnostics on blade 7: switch:admin> bladediag -slot 7 Testing slot: 7, user ports: 3 2 1 0 7 6 5 4 11 10 9 8 15 14 13 12 PortRegTest Running Port Register Test .... passed. Test Complete: "portregtest" Pass 1 of 1 Duration 0 hr, 2 min & 23 sec (0:2:23: 443).
1 1-44 EMC Connectr ix DS-32B2 and ED -12000B Fabr ic OS Reference Manual T elnet Commands bladeDiagShort Run dia gnosti cs on a sw itch blade. Syntax bladediagshort [[-slot] slot ] A v ailability Admin Descr iption Use this comma nd to run a suite of diagnostics tests on the specified switch blad e.
1 bladeDia gShor t 1-45 T elnet Com mands Example T o r un a suite of diagnostics on blade 7: switch:admin> bladediagshort -slot 7 Testing slot: 7, user ports: 3 2 1 0 7 6 5 4 11 10 9 8 15 14 13 12 PortRegTest Running Port Register Test .... passed.
1 1-46 EMC Connectr ix DS-32B2 and ED -12000B Fabr ic OS Reference Manual T elnet Commands bladePr opSho w Display blad e property . Syntax bladePropShow [[-slot] slot ] A v ailability All users Descr iption Use this command to display the pr operties of a blade.
1 camT est 1-47 T elnet Com mands camT e st T o test the function ality of Cont ent Addressable Memory (CAM) . Syntax camtest [-passcnt count ][-txport list ] A v ailability Admin Descr iption Use this command to verify that Con tent Addressable Memory (CAM) is func tionally correct.
1 1-48 EMC Connectr ix DS-32B2 and ED -12000B Fabr ic OS Reference Manual T elnet Commands Example T o v erify that Content Addressable Memor y (C AM) is functioning correctly: switch:admin> camTest Running CAM Test .............. Test Completed: "camtest" Pass 1 of 1.
1 centralMemoryT est 1-49 T elnet Com mands central Memor yT est Perform a bit write/read test of the ASIC central me mory . Syntax centralMemoryTest [ passCount, dataType , dataSeed ] A v ailability Admin Descr iption Use this command to verify the addr ess and da ta bus of the AS IC SRAMs that serve as the central memory .
1 1-50 EMC Connectr ix DS-32B2 and ED -12000B Fabr ic OS Reference Manual T elnet Commands Subtest 3 is not available on 2 G based swi tches. The test method is as follows: 1. Fill the Cent ral Memo ry of all ASI Cs with un ique frames. 2. Set up the har dware such that each ASIC is read by all of the MAX number of po rts in the switch.
1 centralMemoryT est 1-51 T elnet Com mands Subtest 5 The forced bad buf fer number erro r subtest verifies that the bad buffer n umber in the data packet can be detected, its err or flag and interrupt bits are set. The test method is as follows: 1. Clear the err or and interrupt bits of all ASICs.
1 1-52 EMC Connectr ix DS-32B2 and ED -12000B Fabr ic OS Reference Manual T elnet Commands c. Check that all A SIC Y has its: – interrupt bits are set. – err or type is ch ip numb er err or . – the port number in err or is the re ceiver port (which is the base port of asic Y) .
1 centralMemoryT est 1-53 T elnet Com mands Diagnostics When this command detects failure( s), each subtest may re port one or more of the following error messages: Subtest 2 0x20 LCM EM_ERR 0x22 LCM .
1 1-54 EMC Connectr ix DS-32B2 and ED -12000B Fabr ic OS Reference Manual T elnet Commands cfgAdd Add a member to a zo ne confi guration. Syntax cfgAdd " cfgName", "member; member" A v ailability Admin Descr iption Use this command to add o ne or more m embers to an existing zone configuration.
1 cfgClear 1-55 T elnet Com mands cfgClear Clear all zone co nfig urati ons. Syntax cfgClear A v ailability Admin Descr iption This command clears all zone information in the transaction buffer . All defined zone objects in the tran saction buffer ar e deleted.
1 1-56 EMC Connectr ix DS-32B2 and ED -12000B Fabr ic OS Reference Manual T elnet Commands cfgC reate Create a z one co nfig uration . Syntax cfgCreate " cfgName", "member; member" A v ailability Admin Descr iption Use this command to cr eate a new zone conf iguration.
1 cfgCr eate 1-57 T elnet Com mands Example T o create a configuration containing three zones: switch:admin> cfgCreate "Test_cfg", "r edzone; bluezone; greenzone" See Al so cfgA.
1 1-58 EMC Connectr ix DS-32B2 and ED -12000B Fabr ic OS Reference Manual T elnet Commands cfgD elete Delete a zone conf iguration. Syntax cfgDelete cfgName A v ailability Admin Descr iption Use this command to delete a z one configuration. This command changes the defined configuration.
1 cfgD isab le 1-59 T elnet Com mands cfgDisable Disables an ef fective zone configuration. Syntax cfgDisable A v ailability Admin Descr iption Use this command to disable the curr ent zone configuration. The fabric returns to nonzonin g mode where all devices se e each other .
1 1-60 EMC Connectr ix DS-32B2 and ED -12000B Fabr ic OS Reference Manual T elnet Commands cfgEnable Enables a zo ne configuratio n. Syntax cfgEnable cfgName A v ailability Admin Descr iption This com.
1 cfgRe move 1-61 T elnet Com mands cfgR emov e Remove a member fr o m a zone configuration. Syntax cfgRemove " cfgName", "member; member" A v ailability Admin Descr iption Use this command to r emove a member fr om an existing zone configuration.
1 1-62 EMC Connectr ix DS-32B2 and ED -12000B Fabr ic OS Reference Manual T elnet Commands Example T o remo ve a zone from a conf iguration: switch:admin> cfgRemove "Test_cfg", "r ed.
1 cfgSa v e 1-63 T elnet Com mands cfgS a ve Save zon e configu ration to f lash me mory . Syntax cfgSave A v ailability Admin Descr iption Use this command to save the curr ent zone configuration. The defined conf iguration and the name of the enabled co nfiguration ar e written to flash memory in all swi tches in the fab ric.
1 1-64 EMC Connectr ix DS-32B2 and ED -12000B Fabr ic OS Reference Manual T elnet Commands cfgS how Display z one configu ration inf ormation . Syntax cfgShow [" pattern"[, transflag ] A v ailability All users Descr iption Use this com mand to displa y zone config uration inform ation.
1 cfgSho w 1-65 T elnet Com mands Operands This command has the f ollowing operands: Example T o show all zone conf iguration information: switch:admin> cfgShow Defined configuration: cfg: USA1 Blu.
1 1-66 EMC Connectr ix DS-32B2 and ED -12000B Fabr ic OS Reference Manual T elnet Commands T o show only configuration na mes: switch:admin> cfgShow "*" cfg: Test1bluezone cfg: Test_cfgre.
1 cfgT r ansAbo rt 1-67 T elnet Com mands cfgT ransAb or t Abort the current zoning transa ction. Syntax cfgTransAbort A v ailability Admin Descr iption Use this comma nd to abort the current zoning transaction without committing it.
1 1-68 EMC Connectr ix DS-32B2 and ED -12000B Fabr ic OS Reference Manual T elnet Commands cfgTransSh o w Print informa tion about th e current transaction . Syntax cfgTransShow A v ailability Admin Descr iption Use this com mand to show the ID of the current transaction.
1 chassis Name 1-69 T elnet Com mands chassisN ame Display or set th e chassi s name for a n ED-120 00B. Syntax chassisName [ name ] A v ailability Admin ( set) All users (displa y) Descr iption Use this comma nd to change the name associat ed with the chassis ED-12000B.
1 1-70 EMC Connectr ix DS-32B2 and ED -12000B Fabr ic OS Reference Manual T elnet Commands chassisShow Display a ll field replaceable unit s (FRUs). Syntax chassisShow A v ailabiity All users Descr iption Use this co mmand to i nventory and di splay the field replaceable unit (FRU) header cont ent for each object in the chassis.
1 chas sisSho w 1-71 T elnet Com mands Operands None 6 Displays the date the FRU was manufactured. Manufacture: Day: < dd > Month: < mm > Ye a r : < yyyy > 7 Displays the date the FRU header was last updated.
1 1-72 EMC Connectr ix DS-32B2 and ED -12000B Fabr ic OS Reference Manual T elnet Commands Example T o display all Field Replaceable Unit s for a switch: switch12k:admin> chassisShow SW BLADE Slot:.
1 chippr opsh ow 1-73 T elnet Com mands chippro psho w Display ASIC chip property contents. Syntax chippropshow [ slot/ ] chip | [ slot ] -all A v ailability All users Descr iption Use this command to display the ASIC chip property contents for the specified chip on the specified blade slo t.
1 1-74 EMC Connectr ix DS-32B2 and ED -12000B Fabr ic OS Reference Manual T elnet Commands See Als o ptpropshow minispropshow.
1 chip regshow 1-75 T elnet Com mands chipreg show Display port regist ers of a given chi p number . Syntax chipregshow [ slot/ ] chip [ filter ] A v ailability All users Descr iption Use this command to display the ASIC register contents for the specified chip on the specified blade slo t.
1 1-76 EMC Connectr ix DS-32B2 and ED -12000B Fabr ic OS Reference Manual T elnet Commands cmemRetentionT est Run da ta retention te st of the central me mory SRAMs . Syntax cmemRetentionTest [ passCount ] A v ailability Admin Descr iption Use this command to verify for data retention in the central memory SRAMs in the ASIC.
1 cmiTest 1-77 T elnet Com mands cmiT est T est the quad connections between two ASIC co nnections. Syntax cmitest [-passcnt passcnt][-txport lis t][-rxport list][-skip mask] A v ailability Admin Desc.
1 1-78 EMC Connectr ix DS-32B2 and ED -12000B Fabr ic OS Reference Manual T elnet Commands Error s When it detects failure(s), the subtest may r eport one or more of the followi ng err or messag es: D.
1 configDef ault 1-79 T elnet Com mands configD efault Restore system confi guration to default setti ngs. Syntax configDefault A v ailability Admin Descr iption Use this comma nd to reset system configuration to default valu es.
1 1-80 EMC Connectr ix DS-32B2 and ED -12000B Fabr ic OS Reference Manual T elnet Commands configDo wnload Downloa d the switch con figuration from a host file . Syntax configDownload [ host , user , file [, passwd ]] A v ailability Admin Descr iption Use this com mand to down load the s witch configurat ion file from a host system .
1 configDownl oad 1-81 T elnet Com mands Operands This command has the f ollowing operands: Example T o download a bac kup configuration fr om a host system: switch:admin> configDownload "citadel" , "jdoe", "config.txt" Committing configuration.
1 1-82 EMC Connectr ix DS-32B2 and ED -12000B Fabr ic OS Reference Manual T elnet Commands configShow Display sy stem configu ration settings. Syntax configShow [" filter" ] A v ailability All users Descr iption Use this com mand to view system config uration settings set by the configure command.
1 configShow 1-83 T elnet Com mands See Al so agtcfgShow configure diagDisablePost diagEnablePost ipAddrShow licenseShow syslogdIpShow.
1 1-84 EMC Connectr ix DS-32B2 and ED -12000B Fabr ic OS Reference Manual T elnet Commands configUpload Create a backup file of switch confi guration informa tion on a h ost workstat ion.
1 configUpl oad 1-85 T elnet Com mands Example T o create a backup file of swit ch configuration inf or mation: swd5:admin> configDownload "citadel", "jdoe", "config.
1 1-86 EMC Connectr ix DS-32B2 and ED -12000B Fabr ic OS Reference Manual T elnet Commands configure Modify sy stem config uration settings. Syntax configure A v ailability Admin Descr iption Use this.
1 configure 1-87 T elnet Com mands Fabric Parameters There ar e a number of settings that contr ol the overall behavior and operation of the fabric. So me of these values, s uch as the domain, ar e assigned automatically by the fabric and may dif fer from one switch to another in the fabric.
1 1-88 EMC Connectr ix DS-32B2 and ED -12000B Fabr ic OS Reference Manual T elnet Commands Descriptions of the switch fabric setting fields ar e as follows: Domain The domain number un iquely identifies th e switch in a fabric. This value is automatica lly assigned by the Fabric.
1 configure 1-89 T elnet Com mands Sequence Lev el Switching When sequence level switching is set to 1, frames of the same sequence fr om a particular sour ce ar e transmitted together as a group. When this featur e is set to 0, frames ar e transmitted interleaved amo ng multiple sequ ences.
1 1-90 EMC Connectr ix DS-32B2 and ED -12000B Fabr ic OS Reference Manual T elnet Commands Core Switch PID For mat This is used to set the 256 port PID forma t that is used for core switches .
1 configure 1-91 T elnet Com mands The V irtual Channel Setting fields as show in T a ble 1-4: Switch Operating Mode The functional ity of this parameter is currently not supported.
1 1-92 EMC Connectr ix DS-32B2 and ED -12000B Fabr ic OS Reference Manual T elnet Commands NS Pre-zoning Mode The NS Prezoning Mode field is a s follows: Pre-zoned r esponses Mode Specify 0 for Stan dar d Mode, or 1 for Pr e-zoning O n. The default value is 0.
1 configure 1-93 T elnet Com mands Do Not All o w AL_P A 0x00? This option disallows AL P A values from being 0. Initialize All Looplets? When this is set , all looplets incl uding the on es not in the same z one are a lways re-initialized. This is r equired for certain RAID subsystems to work properly during failover .
1 1-94 EMC Connectr ix DS-32B2 and ED -12000B Fabr ic OS Reference Manual T elnet Commands rus ers d Dynamically enables or disables a server that r eturns information about the u ser logged into th e system t hr ough remote procedure calls (RPCs).
1 configure 1-95 T elnet Com mands Por tl o g E ven t s E n a b le Use these parameters to specify which events cr eate an entry in the port log. The Portlog E vents fields are shown in T able 1-7: Ta.
1 1-96 EMC Connectr ix DS-32B2 and ED -12000B Fabr ic OS Reference Manual T elnet Commands nbrfsm: neighbor state transitio n (on, off): [on] timer : timer (on, off): [on] sn: speed negoti ation state.
1 configure 1-97 T elnet Com mands Example T o set the configuration parameters for a switch: switch:admin> configure Configure... Fabric parameters (yes, y, no, n): [ no] yes Domain: (1..239) [1] R_A_TOV: (4000..120000) [10000] E_D_TOV: (1000..5000) [2000] 5000 Data field size: (256.
1 1-98 EMC Connectr ix DS-32B2 and ED -12000B Fabr ic OS Reference Manual T elnet Commands crossP or tT es t T est the functional o peration of the switch. Syntax crossPortTest [ passCount , loopbackmode , speedmode ] A v ailability Admin Descr iption Use this command to verify the fun ctional operation of the switch.
1 cr ossP ortT est 1-99 T elnet Com mands 6. Check if any of the 8 statistic error counters ar e non-zero: ENC_in, CRC_err , T runcFrm, Fr mT ooLong, BadEOF , Enc_out, Ba dOrdSet, DiscC3. 7. Check if the transmit, r eceive or class 3 r eceiver counters are stuck at s ome valu e.
1 1-100 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands T o run the crossPortTest command successfully the test must find at least one port (if singlePortAlso loopback mode is active) or two ports (i f singl ePor tAl so lo opba ck m ode i s not a ctiv e) c able loopbacked to each other .
1 cr ossP ortT est 1-1 01 T elnet Com mands Operands This command has the f ollowing operands: passCount Specify the number of times to execute this test. The default value is 1. This operand is option al. lbmode Select the loopback point for the test.
1 1-102 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands sp Select the speed mode for the test. This parameter is only used for 2 Gb/s capable products where it co ntrols the speed at which each port is operated. For 1 Gb/s only products it is ignored.
1 cr ossP ortT est 1-1 03 T elnet Com mands Example T o ex ecute a functional test of all the ports on a switch 100 times: switch:admin> crossporttest Running Cross Port Test .
1 1-104 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands 0x2f PORT_WRONG 0x30 ERR_STATS_ENCIN 0x31 ERR_STATS_CRC 0x32 ERR_STATS_TRUNC 0x33 ERR_STATS_2LONG 0x34 ERR_S.
1 dataT ypeSh ow 1-105 T elnet Com mands dataTypeSho w Display sa mple data stream types used in some diag nostic commands. Syntax dataTypeShow A v ailability All users Descr iption Displays s ample data streams typ es used in diagn ostic command s. There are 19 differ ent sample data types.
1 1-106 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands date Display or set s ystem d ate and time. Syntax date [" newdate" ] A v ailability All users (displa y) Admin ( set) Descr iption Use this command with no o perands to display date a nd time.
1 date 1-107 T elnet Com mands See Al so errLogShow portLogShow uptime.
1 1-108 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands diagClearError Clear the diag softwar e flag to allow for r etest. Syntax diagclearerror [[-slot] slot][-switch switch] | -all A v ailability Admin Descr iption Use this command to clear the diag software flag that indicates whether a port is BAD or OK.
1 diag Comm andS ho w 1-109 T elnet Com mands diagCommandSho w Display a list o f diagnostic com mands. Syntax diagCommandShow A v ailability Admin Descr iption Use this comman d to display a list of diagnostic co mmands for v4.0. Operands None Example T o display a list of v4.
1 1-110 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands turboramtest Turbo speed as ic SRAM diagnostic statstest Statistics cou nter diagnostic portledtest User Por.
1 diagDi sa bleP ost 1-111 T elnet Com mands diagDisableP ost Disable POST execution at r eboot. Syntax diagDisablePost A v ailability Admin Descr iption Use this command to disable power nn self tes t (POST) execution at switch reboot.
1 1-112 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands diagEnableP ost Enable POST execution at next rebo ot. Syntax diagEnablePost A v ailability Admin Descr iption Use this command to enable power on self tes t (POST) execution at the next switch reboot.
1 diage sdp orts 1-113 T elnet Com mands diagesdports Set ESD skip po rts list. Syntax diagesdports [ list | -show] A v ailability Admin Descr iption Use this command to set the ESD IDLE PORTS list. The list is sa ved in nonvolatile memory and stays in that mode until the next execution of diagesdports .
1 1-114 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands diagfai llimit Set diagn ostics fa il limit. Syntax diagfaillimit [ limit | -show] A v ailability Admin Descr iption Use this command to set the diag nostics f ail limit to a specified value.
1 diagHelp 1-1 15 T elnet Com mands diagHelp Display dia gnostic commands inf ormation . Syntax diagHelp A v ailability All users Descr iption Use this com mand to display a list of the diagno stic help com mands for troubleshooting sw itch problems.
1 1-116 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands turboramtest Turbo speed as ic SRAM diagnostic statstest Statistics cou nter diagnostic portledtest User Por.
1 diaglo opid 1-117 T elnet Com mands diagloopid Set the diag nos ti cs lo op ID . Syntax diagloopid [ id | -show] A v ailability Admin Descr iption Use this command to select the loop ID to be used by FL mode diagnostics.
1 1-118 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands diagmodepr Enable or disable mode messages. Syntax diagmodepr [ mode | -show] A v ailability Admin Descr iption Use this command to enable print mode. The m ode is saved in nonvolatile memory and stays in that mode until the next execution of diagmodepr .
1 diagp ost 1-119 T elnet Com mands diagpost Enable or disable POS T testing. Syntax diagpost [ mode | -show] A v ailability Admin Descr iption Use this command to enable or disable POST testing. The mode is saved in non-vo latile memory an d stays in tha t mode until the next execution of diagpost .
1 1-120 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands diagretr y Enable or dis able re try mode. Syntax diagretry [ mode | -show] A v ailability Admin Descr iption Use this command to enable or disable r etry mode.
1 diagse tbur inin 1-1 21 T elnet Com mands diagsetburinin Initializes the bla de for a burn-in run. Syntax diagsetburnin [-slot [ slot ]] scriptnam e A v ailability Admin Descr iption Use this command to set up the bla de burn-in parameters for the register ed burn-in script.
1 1-122 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands diagsetc y cle Set diagnostic script parameters. Syntax diagSetCycle < script_name > [-show|-def ault|< -keyword value >..] A v ailability Admin Descr iption Use this command to update diagnos tic command parameters.
1 dia gsetc ycle 1-123 T elnet Com mands Example T o view the parameters for a script: switch:admin> diagsetcycle -show Syntax: diagSetCycle <script_name> [ - show | -default | <-keyword valu e>.
1 1-124 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands diagSho w Print diagno stic results since the la st boot. Syntax diagshow [-slot slot][-uports itemlist][-bp.
1 diagShow 1-125 T elnet Com mands Example T o display diagnostic status on switch blade 7: switch:admin> diagshow -slot 7 Diagnostics Status: Wed Feb 13 16:12: 27 2002 Slot: 7 UPORTS Port BPort Di.
1 1-126 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands diagsho wtime Enable or dis able elapsed time messages. Syntax diagshowtime [ mode | -show] A v ailability Admin Descr iption Use this command to enable or disable show time m ode.
1 diagsilk worm 1-127 T elnet Com mands diagsilkw or m Enable or dis able silkworm mode. Syntax diagsilkworm [ mode | -show] A v ailability Admin Descr iption Use this command to enable or disable si lkworm mode. The mode is saved in nonvo latile memo ry and stays in that mode until the next execution of diagsilkworm .
1 1-128 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands diagskiptests Enable or disa ble diagn ostics skip te st flags. Syntax diagskiptests [ limit | -show] A v ailability Admin Descr iption Use thi s command to enable or disable the d iagnost ics skip test f lags.
1 diagsto pburn in 1-129 T elnet Com mands diagstopburnin T erm inat e a bl ade b urn- in run . Syntax diagstopburnin [-slot slot ] A v ailability Admin Descr iption This determ ines which P ID is running burn-in on a blade and terminates that activity .
1 1-130 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands dlsRes et T urn off dyn amic load sh ari ng opt ion. Syntax dlsReset A v ailability Admin Descr iption Use this command to turn of f DLS when a fabric change occurs.
1 dlsReset 1-131 T elnet Com mands Examples T o disable the dynamic load sharing option: switch:admin> dlsReset Committing configuration...done. switch:admin> dlsShow DLS is not set See Al so dl.
1 1-132 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands dlsSet T urn on dyna mic loa d shar ing opti on. Syntax dlsSet A v ailability Admin Descr iption Use this command to enable dynamic load sharing when a fabric change occurs.
1 dlsSe t 1-133 T elnet Com mands Example T o enable the dynamic load sharing option: switch:admin> dlsSet Committing configuration...done. switch:admin> dlsShow DLS is set See Al so dlsReset dl.
1 1-134 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands dlsSho w Display th e state of the d ynamic loa d sharin g (DLS) optio n. Syntax dlsShow A v ailability All users Descr iption Use this command to display whether DL S is on or off.
1 errDum p 1-135 T elnet Com mands errDu mp Display th e err or log with out page breaks. Syntax errDump [-s swinst] [-p] [-a] A v ailability Admin Descr iption Use this comma nd to display the error log without page breaks.
1 1-136 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands Operands This command has the f ollowing operand: Example T o display the err or log without page breaks: sw.
1 errShow 1-137 T elnet Com mands errSh ow Scroll through the err or log. Syntax errShow [-s swinst] [-p] [-a] A v ailability Admin Descr iption Use this com mand to display th e erro r log. This comm and enables you to scroll through the entries using the E NTER key .
1 1-138 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands T a ble 1-8 lists the errShow entries: T a ble 1-9 lists the error code numbers for v4.0, the POST test that generates this number , and the type of error . Ta b l e 1 - 8 errShow Entries Entry Description Error Number Beginning at one.
1 errShow 1-139 T elnet Com mands 0110 0111 0112 040F 0415 0416 Err# 0B0F 0B15 0B16 1020 1021 1025 1026 1027 1028 1029 102A 102B 102C 1030 106F 1F25 1F26 1F27 Ta b l e 1 - 9 Error Codes fo r v4.
1 1-140 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands 2030 2031 2032 2033 2034 2035 2036 223B 223C 2271 2640 2641 2642 2643 2644 Err# 2645 2646 2647 264F 265F 2660 2661 2662 266E Ta b l e 1 - 9 Error Codes for v4.
1 errShow 1-141 T elnet Com mands 266F 2670 2671 3040 3041 3042 3043 3044 3045 3046 3047 304F 305F 3060 3061 3062 306E 306F 3070 3071 3078 3840 3841 3842 3843 Ta b l e 1 - 9 Error Codes fo r v4.
1 1-142 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands Operands This command has the f ollowing operands: Example The follow ing illustrat es entries in th e err o.
1 errShow 1-143 T elnet Com mands Type <CR> to continue, Q<CR> to stop: See Al so errDump firmwareDownload reboot uptime.
1 1-144 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands fabricSho w Displays fa bric membership information . Syntax fabricShow A v ailability All users Descr iption Use this com mand to displa y informatio n about swi tches and multicast alias group s in the f abric.
1 fa b r i c S h ow 1-1 45 T elnet Com mands Example The follo wing example s hows a fa bric of four sw itches. sw180 is the principal switch. Three of the switches ar e configured to r un IP over Fibre Channel.
1 1-146 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands fabStatsSho w Display th e fabric statistics in formation. Syntax fabStatsShow A v ailability All users Descr iption Use this com mand to display th e statistics inf ormation of fabric.
1 fanDisable 1-1 47 T elnet Com mands fanD isable Disab le a fan uni t. Syntax fanDisable unit A v ailability Admin Descr iption Use this com mand to disable a nonfau lty fan unit by s etting the RPM speed to 0.
1 1-148 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands fanE nable Enable a fa n unit. Syntax fanEnable unit A v ailability Admin Descr iption Use this comma nd to set the fan unit back to the default RP M speed only if the fa n unit has been previously dis abled using the fanDisable co mmand.
1 fa n S h ow 1-1 49 T elnet Com mands fanS ho w Display f an status. Syntax fanShow A v ailability All users Descr iption Use this command to display the curr ent status of the switch fans. The format of the display varies accord ing to the number of fans installed .
1 1-150 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands fas t b o ot Reboot the switch, bypassing POST . Syntax fastboot A v ailability Admin Descr iption Use this command to reboot th e switch, bypassing POST .
1 fa z o n e A d d 1-151 T elnet Com mands faz o n eA d d Add a member to a Fabri c Assis t zone. EMC does not support this comm and. Syntax fazoneAdd “ fazoneName ” , “ member ; member ” A v ailability Admin Descr iption Use this command to add one or more members to an existing Fabric Assist zone.
1 1-152 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands Example T o add aliases f or some disk arrays to “ Blue_f azone ” : switch:admin> fazoneAdd “ Blue_.
1 fa z o n e C r e a t e 1-1 53 T elnet Com mands faz o n eC r e a te Create a Fabric Assist zone. EMC does not support this comm and. Syntax fazoneCreate “ fazoneName ” , “ member ; mem ber ” A v ailability Admin Descr iption Use this command to cr eate a n ew Fabric Assist zo ne.
1 1-154 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands A Fa bric Assis t host m ember is de fined by wr apping the physi cal fabric port or a physical device (a WWN) between “ H{ ” and “ } ” . For example, “ H{5,6} ” or “ H{10 :00 :00: 60: 69:0 0:00 :8a } ” is a Fabric Assis t host.
1 fa z o n e C r e a t e 1-1 55 T elnet Com mands Example T o create three Fabric Assist zones using a mixture of port numbers and Fabric Assist zone aliases: switch:admin> fazoneCreate “ fazon e.
1 1-156 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands faz o n eD e l et e Delete a Fabric Assist mo de zone. EMC does not support this comm and. Syntax fazoneDelete “ fazoneName ” A v ailability Admin Descr iption Us e th is c om man d t o de le te a n ex is tin g F abr ic Ass ist mo de z one on a fabric.
1 fa z o n e R e m ov e 1-1 57 T elnet Com mands fa zo n e R e m ove Remo ve mem bers fr om a Fabr ic Assist mode zone. EMC does not support this comm and. Syntax fazoneRemove “ fazoneName ” , “ member; me mber ” A v ailability Admin Descr iption Use this command to r emove one or mor e members fr om an existing Fabric Assist zo ne.
1 1-158 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands Operands The following operands are r equired: Example To remove “ array2 ” from “ Blue_ fazone ” : .
1 fa z o n e S h o w 1-159 T elnet Com mands faz o n eS h ow Display f azone info rmation. EMC does not support this comm and. Syntax fazoneShow [" pattern "[, transflag ]] A v ailability All users Descr iption Use this com mand to display f azone info rmation.
1 1-160 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands Example T o display all f azones beginning with the letter s A thr ough C: switch:admin> fazoneShow ".
1 filterT est 1-1 61 T elnet Com mands filterT est Run frame fi lter test for 3 000 ASICs. Syntax filterTest [-passcnt passcnt][-txports list][-scamoff offset] [-dcamoff offset][-fdefoff off set] A v .
1 1-162 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands Operands This command has the following operands: Diagnostics When it detects failure(s), the subtest may r .
1 filterT est 1-1 63 T elnet Com mands Example T o r un the filterT est: switch:admin> filterTest Running Filter Test ........... passed . See Al so ramTest portRegTest cmiTest centralMemoryTest sr.
1 1-164 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands fir mwa re C o m mi t Comm it s witc h fi rmwar e updat e. Syntax firmwareCommit A v ailability Admin Descr iption Use this command to propagate an updated firmware image in the primary partiti on to the secondar y partition in an individual CP blade.
1 fir m wa r e D ow n l o a d 1-165 T elnet Com mands fir mwa re D ow nl o ad Downloa d a switch fi rmware file from a host. Syntax firmwareDownload [[-sbni] host,user,pf ile [, passwd]] A v ailabilit.
1 1-166 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands Operands This comman d has the following operands: -s Specify this o ption to enable Single CP Mode. This option is available in v4.0 only . In th e ED-12000B, by default, firmwareDownload w ill upgrade both CPs.
1 fir m wa r e D ow n l o a d 1-167 T elnet Com mands If no operand is specified, the o peration becom es interact ive and you are pr o mpted for input. Example T o download a f irmware f ile: switch:admin> firmwaredownload Server Name or IP Address: 192.
1 1-168 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands Errors The following can cause the download to fail: ◆ The host name i s no t kno wn to the swit ch. ◆ The host IP addr ess cannot be contacted. ◆ The user does not have permission on the host.
1 fir m wa r e R e s to r e 1-169 T elnet Com mands fir mwa re R e st o r e Restore old active firmware image from the secondary partition. Syntax firmwareRestore A v ailability Admin Descr iption Use this command to restor e the old active firmware image.
1 1-170 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands fsp fSh ow Display FSPF proto col i nformation . Syntax fspfShow A v ailability All users Descr iption Use this comma nd to display the Fibre-Channel Shortest Path First (FSPF) protocol informatio n, and int ernal data structures.
1 fspfS ho w 1-171 T elnet Com mands Operands None Examples T o display FSPF protocol information: switch:admin> fspfshow version = 2 domainID = 1 switchOnline = TRUE domainValid = TRUE domainConfi.
1 1-172 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands See Als o bcastShow mcastShow topologyShow uRouteShow.
1 fwAlar msFilterSet 1-1 73 T elnet Com mands fwAlar msFilterSe t Show which a larms are enabled for Fabric W atch. Syntax fwAlarmsFilterSet [ mode ] A v ailability Admin Descr iption Use this com mand to configure alarm filtering. By turni ng off the alarm s, all no nenv ironment cla ss ala rms are supp ressed.
1 1-174 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands fwAlar msFilterShow Show al arm filtering for Fabric W a tch. Syntax fwAlarmsFilterShow A v ailability All users Descr iption Use this com mand to show alarm filterin g status for Fabric W a tch.
1 fwCl assIn it 1-175 T elnet Com mands fwClassInit Initialize all classes under Fabric W atch. Syntax fwClassInit A v ailability Admin Descr iption Use this com mand to initial ize all classes und er Fabric W atch. This comm and r equir es a Fabric W atch license.
1 1-176 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands fwConfigReload Reload the Fabric W a tch configurat ion. Syntax fwConfigReload A v ailability Admin Descr iption Use this comman d to initia lize reload the F abric W atch co nfigurati on.
1 fwConfigure 1-177 T elnet Com mands fwConf igure Display and modify the Fabric W atch configura tion and status . Syntax fwConfigure A v ailability Admin Descr iption Use this command to display and modify thresho ld information fo r the Fabric W atch co nfigurati on.
1 1-178 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands Fabric class Loss of E_ Port Fabric reconfigure Segmentatio n changes Doma in ID cha nges Zonin g chang es Fabric to Quic kLoop changes.
1 fwConfigure 1-179 T elnet Com mands Fabric class Loss of E_ Port Fabric reconfigure Segmentatio n changes Doma in ID cha nges Zonin g chang es Fabric to Quic kLoop changes.
1 1-180 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands Operands None Example T o reload the sa ve d Fabric W atch conf iguration: switch:admin> fwConfigure 1 : .
1 fwConfigure 1-181 T elnet Com mands inBetween Thu Aug 1 10:4 9:44 2002 30 C Norma l 3 envTemp003 enabled 42 C inBetween Thu Aug 1 10:4 9:44 2002 47 C Norma l 5 envTemp005 enabled 38 C inBetween Thu .
1 1-182 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands fwFruCfg Display or m odify FRU sta te alert config uration. Syntax fwFruCfg A v ailability Admin Descr iption Use this command to configur e FRU states an d actions.
1 fwFr uCfg 1-1 83 T elnet Com mands 1 Slot #1 enable 32 17 5 Minute 2 Slot #2 enable 8 16 1 Minute 3 Slot #3 enable 16 16 1 Minute 4 Slot #4 enable 48 17 5 Minute 1 : change fru alarm state 5 : ch an.
1 1-184 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands fwHelp Display Fa bric W a tch command in formatio n. Syntax fwHelp A v ailability All users Descr iption Use this com mand to display com mands used to co nfigure Fabric Wa t c h .
1 fwMailC fg 1-185 T elnet Com mands fwM ail Cfg Configure email alerts in Fabric W atch. Syntax fwMailCfg A v ailability Admin Descr iption Use this command to configur e email alerts in Fabric W atch. This comm and r equir es a Fabric W atch License.
1 1-186 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands When config uring an email alert for a s pecific class, yo u must specify the follow ing info rmation: If the swi tch is r ebooted using switchboot,rebo ot , or fastboot , the email al ert is s et to d isabled and mus t be r eenabled again .
1 fwMailC fg 1-187 T elnet Com mands Example T o configure an email address rec ipient in F abric Watch: switch:admin> fwMailCfg 1 : Show Mail Configuration Informatio n 2 : Disable Email Alert 3 :.
1 1-188 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands fwSetT oCustom Set boundary and alarm levels to custo m values. Syntax fwSetToCustom A v ailability Admin Descr iption Use this comman d to set boundary and a larm levels to cust om values for all classes a nd areas for Fabric W atch.
1 fwSe tT oDefault 1-189 T elnet Com mands fwSetT oDef ault Set boundary and alar m levels to the default values. Syntax fwSetToDefault A v ailability Admin Descr iption Use this co mmand to set bou ndary and alarm levels to default v alues for all classes a nd areas for Fabric W atch.
1 1-190 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands fwsh o w Display th e thresholds monit ored by Fabric W atch. Syntax fwShow A v ailability All users Descr iption Use this comma nd to display the thresholds monitored by Fabric Wa t c h .
1 fwsho w 1-1 91 T elnet Com mands Counter: Access via: Function call Address: 0x100187dc Argument: 0x00000002 Previous: 0x00000bc5 (3013) Current: 0x00000bc5 (3013) Events: Style: Triggered Event 0 o.
1 1-192 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands gbicSho w Display serial ID G BIC informa tion. Syntax gbicShow [ slotnumber /][ portnumber ] A v ailability All users Referen ces to GBI C also apply to S FP .
1 gbicSh ow 1-193 T elnet Com mands Operand This command has the f ollowing operand: slotnumber Specify the sl ot number in an ED-12000 B switch. The slot number must be followed by a slash ( / ) and the port number . The ED-12000B has a tota l of 10 slots counted fr om 1 to 10.
1 1-194 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands Example T o display GBIC summary information, follo w ed by detailed information f or a single GBIC: switch12k:admin> gbicshow Area 0: id (id) Vendor: Serial No: Area 1: id (sw) Vendor: FINISAR CORP.
1 gbicSh ow 1-195 T elnet Com mands switch12k:admin> gbicshow 1/3 Identifier: 3 GBIC Connector: 7 LC Transceiver: 050c402000000000 100,200_ MB/s M5,M6 sw Inter_dist Encoding: 1 8B10B Baud Rate: 21 .
1 1-196 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands h Display sh ell history . Syntax h A v ailability All users Descr iption The shell hist ory mecha nism is sim ilar to the UNIX Korn shell h istory facility .
1 haDisab le 1-197 T elnet Com mands haDisable Disable the hi gh-avai lability feature in the switch. Syntax haDisable A v ailability Admin Descr iption Use this co mmand to disable th e high-availabi lity (HA) feature in the switch. If the HA featur e is alr eady disabled, this command is ignored.
1 1-198 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands haEnable Enable the high -availability fe ature in the switch. Syntax haEnable A v ailability Admin Descr iption Use this com mand to enable the hi gh-availa bility (HA) featu re in the Switch.
1 haFailover 1-199 T elnet Com mands haF ailo ver Force the fa ilover mechanism so that the standby CP becomes the act ive C P . Syntax haFailover A v ailability Admin Descr iption Use this com mand to force the failover mechanism to occur so that the standby CP becomes the active CP .
1 1-200 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands haSho w Display con trol pr ocessor (CP) s tatus. Syntax haShow A v ailability Admin Descr iption Use this c.
1 help 1-201 T elnet Com mands help Display hel p informat ion for comma nds. Syntax help [ command ] A v ailability All users Descr iption Use this com mand withou t an operand to displ ay an alphab etical list of commands that provide help information.
1 1-202 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands histor yLastSho w Display la st history record. Syntax historyLastShow A v ailability All users Descr iption Use this comma nd to display the contents of the las t history log rec o rd .
1 histor yShow 1-203 T elnet Com mands histor ySho w Display th e history lo g. Syntax historyShow A v ailability All users Descr iption Use this com mand to display th e history log.
1 1-204 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands Example T o display the entir e contents of the histor y file: switch:admin> historyShow FAN Unit 3 Remov.
1 i 1-205 T elnet Com mands i Display ta sk summary . Syntax i [ taskId ] A v ailability All users Descr iption This command displays information of all of the pro cesses or of a specific process if a process ID is supplied. One line is displayed per process.
1 1-206 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands Operands This command has the f ollowing operand: Example T o display inf ormation about process ID 433: swi.
1 ifMod eSet 1-207 T elnet Com mands ifModeSet Set the link operatin g mode for a network interface. Syntax ifModeSet [" eth0" ] A v ailability Admin Descr iption Use this command to set the link operating m ode for the ethernet interface. Use ifShow to list network interfaces a vailable on the system.
1 1-208 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands Example T o f orce the link f or the eth0 Ethernet interface to auto negotiate and to advertise all possible operating modes: switch:admin> ifModeSet "eth0" Exercise care when using this command.
1 ifMod eShow 1-209 T elnet Com mands ifModeSho w Display th e link operating m ode for a networ k interface. Syntax ifModeShow [" eth0" ] A v ailability All users Descr iption Use this comma nd to display the link operating mode for a network interface.
1 1-210 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands interfaceSho w Display FSPF interface informa tion. Syntax interfaceShow [ slotnumber /][ portnumber ] A v ailability All users Descr iption Use this command to display data str uctures associated with FSPF interfaces (E_Por ts) on the switch .
1 interfaceShow 1-211 T elnet Com mands delay: Conv entio nal d elay inc urr ed b y a fra me transmitted on this ISL. A fixed value requir ed by the FSPF pro tocol. lastScn: T ype of the last Sta te Change Notificatio n received on this interface. lastScnTime: T ime the last State Change Notification was received on this interface.
1 1-212 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands &dbRetransList: Pointer to the database retransmission list. &lsrRetransList: Pointer to the Link State Records (LSR) retransmi ssion li st. &lsrAckList: Pointer to the Link Stat e Acknowledgem ents (LSA) retransmissio n list.
1 interfaceShow 1-213 T elnet Com mands nInvHlo: Number of in valid Hello fra mes (Hello frames with invalid parameters) r eceived from the neighbor switch. nLsuIn: Number of LSUs received from the neighbor switch. nLsaIn: Number of LSAs received from the neighbor switch.
1 1-214 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands Operands This command has the f ollowing operands: When no slot number and port number are specified, this command displays the interfac e informatio n for all ports on the swi tch (inclu ding n on E_Ports) .
1 interfaceShow 1-215 T elnet Com mands See Al so portShow switchShow.
1 1-216 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands interopmode Enable or disable switch interoperability with sw itches from other manufa cturers. Syntax interopMode [ mode ] A v ailability Admin Descr iption Use this command to enable or disable inter operability mode for individual sw itches.
1 inte ro pmo de 1-217 T elnet Com mands Example T o view and then enable inter operability mode: switch:admin> interopmode InteropMode: Off Usage: InteropMode 0|1 0: to turn it off 1: to turn it on switch:admin> interopmode 1 done. Interopmode is enabled.
1 1-218 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands iodRes et T u rn off the in-order delivery (IOD) option. Syntax iodReset A v ailability Admin Descr iption Use this comma nd to turn off the IOD option. The IOD optio n is turned off by default.
1 iodSet 1-2 19 T elnet Com mands iodSet T urn on in-order deli very op tion. Syntax iodSet A v ailability Admin Descr iption Use this command to enfor ce in -or der delivery of frames during a fabric topology change. In a stable fabric, fr ames are always delivered in order , even when the traffic between switches is shared among mu ltiple paths.
1 1-220 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands iodSho w Display th e state of the in-o rder Delivery (IOD) option. Syntax iodShow A v ailability All users Descr iption Use this command to display whetherthe in-order delivery option during topolo gy changes is on o r off.
1 ipAdd rSet 1-221 T elnet Com mands ipAddrSet Set Ethernet an d FC IP addr esses. Syntax ipAddrSet [option] A v ailability Admin Descr iption For v4.0 you m ust set values for both logical swit ches and both CP cards in the ED- 1 2000B chassis. Th e option opera nd is available in v4.
1 1-222 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands ◆ cp0 = hos tname cp0, i p 10.77 .77.75, subnet 255.0. 0.0, g ateway 0.0. 0.0 ◆ cp1 = hos tname cp1, i p 10.77 .77.74, subnet 255.0. 0.0, g ateway 0.0. 0.0 After each pr ompt the curr ent value is shown.
1 ipAdd rSet 1-223 T elnet Com mands Example T o set the IP address details f or log ical switch number 1: switch:admin> ipAddrSet 1 Ethernet IP Address [0.0.0.0]: 192.168 .166.148 Ethernet Subnetmask [0.0.0.0]: 255.255 .255.0 Fibre Channel IP Address [0.
1 1-224 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands ipAddrSho w Display ethernet and FC IP addres ses. Syntax ipAddrShow [ option ] A v ailability All users Des.
1 ipAdd rSho w 1-2 25 T elnet Com mands Operands This command has the f ollowing operand: Example T o display the IP addresses f or log ical switch number 0: switch12000:admin> ipAddrShow 0 Ethernet IP Address: 192.168.166.147 Ethernet Subnetmask: 255.
1 1-226 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands islSho w Display IS L informat ion. Syntax islShow A v ailability All users Descr iption Use this com mand to display the current connections a nd status of the ISL of each port on this swi tch.
1 license Add 1-2 27 T elnet Com mands licenseAdd Add license key to sw itch. Syntax licenseAdd " license " A v ailability Admin Descr iption Use this com mand to add a license key to a switch. Some featur es of the switch and of the fabric to which it is connected are optional licensed pr o ducts.
1 1-228 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands licenseHe lp Display commands used to administer license keys. Syntax licenseHelp A v ailability Admin Descr iption Use this command to display a list of the commands used to administer licen se keys.
1 licen seIdShow 1-229 T elnet Com mands licenseIdShow Display sy stem license ID. Syntax licenseIdShow A v ailability All users Descr iption Some featur es of the ED-1200 0B and the fabric are optional, licen sed products. W ithout a licen se installed for such products, the services provided by these features ar e n ot available.
1 1-230 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands licenseRem o v e Remove the license key from a s witch. Syntax licenseRemove " license " A v ailability Admin Descr iption Use this command to r emove an existing license key fr om a switch.
1 license Show 1-231 T elnet Com mands licenseShow Display current license keys. Syntax licenseShow A v ailability All users Descr iption Use this com mand to display current license keys along with a list of licensed products enabled by these keys; None is d isp layed if no license keys are installed.
1 1-232 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands linkCost Set or print the FSPF co st of a link. Syntax linkCost [slotnumber/][portnumber][, c ost] A v ailability Admin Descr iption Use this comma nd to set or display the cost of an inter-switch lin k (ISL).
1 link Cost 1-233 T elnet Com mands Operands This command has the f ollowing operands:. If no operands ar e specified, the curr ent values for all ports on the switch are disp layed. slotnumber Specify the s lot number in an ED-12000 B switch. Th e slo t nu mb er m ust be f oll ow ed b y a s la sh ( / ) and the port number .
1 1-234 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands Examples T o display the cost of a link, and reset the cost: switch:admin> linkCost Slot Interface Cost -.
1 login 1-2 35 T elnet Com mands log in Log in as a new user . Syntax login A v ailability All users Descr iption Use this com mand to log in to the switch with anothe r username and password, withou t first logging out from the original sess ion. If the user was origin ally conn ected using aT elnet o r rlogin sess ion, that session is left open .
1 1-236 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands logout Log out from aT elnet, rlogin, or serial port session. Syntax logout A v ailability All users Descr iption Use this command to log out fr om a T elnet, rlogin, or serial port session.
1 loopdia gStar t 1-237 T elnet Com mands loopdiagStart Start loopd iag appli cati on. Syntax loopdiagStart port A v ailability Admin Descr iption Use this com mand to start the loopdia g application at the po rt specified. It will isolate the loop device befor e running diagnostics an d re p o r t th e t e s t re su lt .
1 1-238 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands LSDbShow Display th e FSPF link state d atabase. Syntax LSDbShow [ domain ] A v ailability All users Descr iption Use this command t o display a link sta te databas e recor d for sw itches in the fabric.
1 LSDb Show 1-239 T elnet Com mands uOutIfs Internal variable. uPathCost Internal variable. uOldHopCount Internal variable. uHopsFromRoot Internal variable. mOutIfs Internal variable. parent Internal variable. mPathCos Internal variable. mHopsFromRoot Internal variable.
1 1-240 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands Operands This command has the f ollowing operand: Example T o display the link state record for the local sw.
1 LSDb Show 1-241 T elnet Com mands Link State Record: Link State Record pointer = 0x1035bb30 lsAge= 138 reserved= 0 type= 1 options= 0x0 lsId= 7 advertiser= 7 incarn= 0x80000217 length= 92 chksum= 0x.
1 1-242 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands lutil Run the l icense admi nistration utility . Syntax lutil [-h-v][[-i]|[[-a|-r] key ... ]] A v ailability Admin Descr iption Use this command to add, d isplay , and remove license keys.
1 lutil 1-2 43 T elnet Com mands See Al so licenseAdd licenseHelp licenseIdShow licenseRemove licenseShow.
1 1-244 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands mcastShow Display mu lticast routing inform ation. Syntax mcastShow [ group_ID ] A v ailability All users De.
1 mcas tSh o w 1-245 T elnet Com mands Operand This command has the f ollowing operand: Examples T o display multicast rout ing information: switch:admin> mcastShow 9 GroupMember Ports Member ISL P.
1 1-246 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands memshow Display th e amount of free and used memory in switch.
1 minispropshow 1-247 T elnet Com mands minispr opsho w Display th e properties of the miniswitches. Syntax minispropshow {slot/] minis | {slot] - all A v ailability All users Descr iption Use this command to display the ASIC minis witch properties for the specified minis on the specified bla de slot.
1 1-248 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands Example T o vie w the miniswitch prop er ties on blade 8: switch12k:admin> minispropshow 8 -all Looking f.
1 minisreg sho w 1-249 T elnet Com mands minisr egsho w Display port registe rs for a specified mini switch. Syntax minisregshow [slot/]mini_switch {filte r} A v ailability All users Descr iption Use this command to display the ASIC register contents for the specified minis witch on the specif ied blade shot.
1 1-250 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands msCa pabilitySho w Display the man agement server capability . Syntax msCapabilityShow A v ailability All users Descr iption Use this command to query a f abric for the Management Server capability .
1 msCa pa bilityShow 1-251 T elnet Com mands See Al so msPlMgmtActivate msPlMgmtDeactivate msPlatShow msPlClearDB msTdEnable msTdDisable msTdReadConfig.
1 1-252 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands msConf igure Confi gur e the Ma nagem ent Serv er . Syntax msConfigure A v ailability Admin Descr iption Use this command to display and configure parameters used to access the Management Se rver .
1 msConfigure 1-253 T elnet Com mands Example T o display the Management Ser ver access cont rol list: switch:admin> msConfigure 0 Done 1 Display the access list 2 Add member based on its Port/Node WWN 3 Delete member based on its Port/Node W WN select : (0.
1 1-254 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands msPla tShow Display the Ma nagement Server platform database. Syntax msPlatShow A v ailability Admin Descr iption Use this comma nd to display the Managem ent Server platform database.
1 msPlClearDB 1-255 T elnet Com mands msPlClearDB Clear the Management Server platf orm database on all switches in the fabric. Syntax msPlClearDB A v ailability Admin Descr iption Use this command to clear the entire Management Server platform database on all switches in the fabr ic.
1 1-256 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands msPlMgmtA ctiv ate Activate the Platform Database Management service on a ll switches in the fabric.
1 msPlMgmtDeac tiv ate 1-2 57 T elnet Com mands msPlMgmtD eactiv ate Deactivates the Platform D atabase Management service on all switches in th e fabric. Syntax msPlMgmtDeactivate A v ailability Admin Descr iption Use this command to deactivate the Platform Database Man agement service.
1 1-258 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands msTDDisa ble Disable the Management Server T opology Discovery Management service.
1 msTDEna ble 1-259 T elnet Com mands msTDEnable Enable the Managemen t Server T o pology Dis covery Managemen t service. Syntax msTdEnable ["ALL"] A v ailability Admin Descr iption Use this command to enable the Management Server T opology Discovery Mana gement Service local ly or fabric-wide.
1 1-260 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands msTDReadCo nfig Display th e status of Man agement Server T opolo gy Discovery service. Syntax msTdReadConfig A v ailability All users Descr iption Use this command to check whether the Man agement Server T o pology Disco very service is enabled.
1 myid 1-2 61 T elnet Com mands my i d Display th e current login session deta ils. Syntax myid A v ailability Admin Descr iption Use this comma nd to display the status of th e system and the login session details. The status sho ws wheth er the sys tem is Red undan t, Non-Re dund ant, or U nknow n.
1 1-262 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands nbrStatsClear Reset FSPF in terface counters. Syntax nbrStatsClear [slotnumber/][portnumber ] A v ailability All users Descr iption Use this com mand to reset the counters of FSPF fram es transmitted and rece ived on an i nterf ace.
1 nbrStatsC lear 1-263 T elnet Com mands Example T o display how to reset the count ers on por t 4: switch:admin> nbrstatsclear 1/4 See Al so interfaceShow portShow switchShow.
1 1-264 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands nbrStateShow Display FS PF neighbor ’ s state. Syntax nbrStateShow [slotnumber/][portnumber] A v ailabilit.
1 nbrStateShow 1-265 T elnet Com mands Operands This command has the f ollowing operands: Example T o display information about switches directly connected to the lo cal switch: switch:admin> nbrSt.
1 1-266 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands nsAllSho w Display glo bal Name Server informa tion. Syntax nsAllShow [ type ] A v ailability All users Descr iption Use this com mand to displa y the 24-bit Fibre Channel addresses o f all devices in all switches in the fabric.
1 nsAllShow 1-267 T elnet Com mands See Al so nsShow switchShow.
1 1-268 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands nsSho w Display lo cal Name Server inf ormatio n. Syntax nsShow A v ailability All users Descr iption Use th.
1 nsShow 1-269 T elnet Com mands There may be additional lines if the device has registered any of the following i nformati on (the switch a utomatica lly registers SCSI inquiry data for FCP target de.
1 1-270 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands passwd Change syst em login name and pas sword. Syntax passwd [-o] ["user"] A v ailability All users Descr iption Use th is comma nd to change the s ystem pass words.
1 passwd 1-271 T elnet Com mands Use the follow ing options to control input: Operands This command has the f ollowing operands: Example T o change the admin user name and passw ord: switch:admin> passwd "admin" Changing password for admin Enter new password: ******** Re-type new password: ******** Password changed.
1 1-272 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands Error s All error messages are pr eceded by the command n ame with one of the messa ges appende d as shown in T able 1- 19: See Als o login logout Ta b l e 1 - 1 9 Err or Messages Error Message Descrip tion User is not a valid user name.
1 perf AddE EMoni tor 1-273 T elnet Com mands perfAddEEMo nitor Add e nd- to -end moni tor to a port . Syntax perfAddEEMonitor [slotnumber/]portnumb er, "SourceID", "DestID" A v ailability Admin Descr iption Use this command to add an end-to-end m onitor to a port.
1 1-274 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands After a successf ul execution of this command, a monitor number is displayed. The monitor number is pr ovided for eas y manipulation of these performance monitors.
1 perf AddE EMoni tor 1-275 T elnet Com mands Example T o add an end-to-end monitor to blade 7, pot 2: switch:admin> perfAddEEMonitor 7/2, "0 x058e0f", "0x1182ef" End-to-End monitor number 0 added.
1 1-276 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands perfAddIPMonitor Add a filt er-bas ed monitor for IP frame count.
1 perf AddI PMoni tor 1-277 T elnet Com mands Example T o add an IP monitor to blade 2, port 4: switch:admin> perfAddIPMonitor 2/4, 2 IP traffic frame monitor #0 added switch:admin> See Al so pe.
1 1-278 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands perfAddReadMo nitor Add a filt er-bas ed monitor fo r the SCSI Read command.
1 perfAddR eadMo nitor 1-2 79 T elnet Com mands Example T o add a SCSI Read monitor to port 2: switch:admin> perfAddReadMonitor 2/4, 2 SCSI Read filter monitor #2 added switch:admin> See Al so p.
1 1-280 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands perfAddRWMonitor Add a moni tor for the SCSI Read an d W rite commands.
1 perf AddRWM onit or 1-281 T elnet Com mands Example T o add a SCSI Read and Write monitor to blade 2, port 4: switch:admin> perfAddRWMonitor 2/4 SCSI Read/Write monitor #1 is added switch:admin&g.
1 1-282 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands perfAddSCSI Monitor Add a monitor fo r SCSI frame count. Syntax perfAddSCSIMonitor [slotnumber/]portnu mber[, "alias"] A v ailability Admin Descr iption Use thi s command to define filter-based monitors to count the number of SCSI traf fic frames.
1 per fAdd SCSI Moni tor 1-283 T elnet Com mands Example T o add a SCSI traffic f rame monitor to blade 2, port 4: switch:admin> perfAddSCSIMonitor 2/4 SCSI traffic frame monitor #0 added switch:ad.
1 1-284 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands perfAddUserMonitor Add a user -defined filter-ba sed monitor .
1 perfAd dUserMo nitor 1-2 85 T elnet Com mands Operands This command has the f ollowing operands: slotnumber Specify the slot number in an ED-120 00B switch . The slot numb er must be follo wed by a slash ( / ) and the port number . The ED- 12000 B has a t otal o f 10 s lots cou nted from 1 to 10.
1 1-286 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands grouplist Specify up to 6 sets of Offset, M ask, and V alueList separated by a semicolo n (;). The entire grouplist operand must be enclosed in quotation marks.
1 perfAd dUserMo nitor 1-2 87 T elnet Com mands Example T o add a filter based monitor f or all Extended Link Service request (R_CTL=0x22 and TYPE=0x01) to blade 2, p ort 4: switch:admin> perfAddUs.
1 1-288 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands perfAddWriteMonitor Add a filter -based moni tor for the SCSI W rite command.
1 perfAddWr iteMo nitor 1-289 T elnet Com mands Example T o add a SCSI Write command monitor to blade 2, port 4: switch:admin> perfAddWriteMonitor 2/4 SCSI Write filter monitor #0 added switch:admi.
1 1-290 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands perfCfgCle ar Clear the pr eviously saved performance monitoring configuration settin gs fro m flash memory .
1 perfCfgR estore 1-2 91 T elnet Com mands perfCfgRe store Restore performance monitoring configuration setting s fro m flash memory . Syntax perfCfgRestore A v ailability Admin Descr iption Use this comma nd to restor e the performance monito ring configuratio n informatio n from flash memo ry .
1 1-292 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands perfCfgSa v e Save performance m onitoring configuration settings to flash mem ory .
1 perfC lrAlpa Crc 1-293 T elnet Com mands perfClrAlpaCr c Clear an ALP A device ’ s CRC count by the port and ALP A. Syntax perfClrAlpaCrc [slotnumber/]portnumber [, ALPA] A v ailability Admin Descr iption Use this command to clear specific ALP A device's CRC er ror counter .
1 1-294 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands Example T o c lear CRC count on a particular ALP A on port 15, and then clear CRC count for a ll ALP As on blade 2, port 15: switch:admin> perfClrAlpaCrc 2/15, 0x5 9 CRC error count at ALPA 0x59 on port 1 5 is cleared.
1 per fDel EEMon itor 1-295 T elnet Com mands perfDelEEMonitor Delete an end-to-end mo nitor on port. Syntax perfDelEEMonitor [slotnumber/]portnumb er[, monitorId] A v ailability Admin Descr iption Use this command to dele te an end-to-end monitor o n a port.
1 1-296 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands Example T o delete an end-to-end monitor on blade 7, port 2: switch:admin> perfDelEE Monitor 7/2, 5 End-t.
1 perfD elFilterM onitor 1-2 97 T elnet Com mands perfDelFilterMonitor Delete a filter-based monitor . Syntax perfDelFilterMonitor [slotnumber/]port number[, monitorId] A v ailability Admin Descr iption Use this comma nd to delete a filter-based monitor .
1 1-298 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands Example T o delete f ilter monitor 4 on blade 2, port 3: switch:admin> perfDelFilterMonitor 2/3 , 4 The specified filter-based monitor is deleted.
1 perfHelp 1-299 T elnet Com mands perfHelp Display performa nce monito ring help in formation. Syntax perfHelp A v ailability All users Descr iption Use this comma nd to display the available performa nce monitoring help co mman ds. This comm and r equir es a Pe rformance Monitoring license.
1 1-300 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands perfSetP or tEEMask Set overall mask for end-to-end (EE) monitors.
1 perfSe tP or tEEMask 1-301 T elnet Com mands Operands This command has the f ollowing operands: slotnumber Specify the s lot number in an ED-120 00B switch. The slot n umber must be follow ed by a slash ( / ) and the port number . The ED- 12000B ha s a total of 10 slots counte d from 1 to 10.
1 1-302 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands Example T o set the o v erall mask f or end-to-end monitors on blade 2, port 4: switch:admin> perfSetPort.
1 perfShowAlpaCrc 1-303 T elnet Com mands perfSho wAlpaCrc Display the ALP A CRC count by port or by ALP A. Syntax perfShowAlpaCrc [slotnumber/]portnumbe r[, ALPA] A v ailability Admin Descr iption Use this command t o display a s pecific ALP A device CRC error count by the port or ALP A .
1 1-304 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands Example T o display the CRC err or count f or all ALP A devices on blade 2, port 4: switch:admin> perfSho.
1 perf Sho w EEMon itor 1-305 T elnet Com mands perfSho wEEMonitor Display end- to-end monito r information and frame tra ffic on a port. Syntax perfShowEEMonitor [slotnumber/]portnum ber[, interval] A v ailability Admin Descr iption Use this comma nd to display end-to-end monito r information and frame traf fic on a port .
1 1-306 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands Operands This command has the f ollowing operands: slotnumber Specify the s lot number in an ED-120 00B switch. The slot number must be followed by a slash ( / ) and the port n umber .
1 perf Sho w EEMon itor 1-307 T elnet Com mands Example T o display end to end monitor frame tra ffic on b l ade 4 , p or t 5 a t an inter va l of ev er y 6 seconds: switch:admin> perfShowEEMonitor.
1 1-308 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands perfSho wFilterMonitor Display filter-based mo nitor informa tion and f rame traffic for a port.
1 perfShowFilterMo nitor 1-3 09 T elnet Com mands Operands This command has the f ollowing operand: slotnumber Specify the s lot number in an ED-120 00B switch. The slot n umber must be follow ed by a slash ( / ) and the port number . The ED- 12000B ha s a total of 10 slots counte d from 1 to 10.
1 1-310 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands Example T o display f ilter monitor traf fic on blade 2, port 5 at an inter va l of ev er y 6 seconds: switc.
1 perfShowP or tEEMask 1-311 T elnet Com mands perfSho wPortEEMask Displays the curren t end-to-end mask of a port. Syntax perfShowPortEEMask [slotnumber/]portnu mber A v ailability Admin Descr iption Use this comma nd to display the current end-to-end mask of a port.
1 1-312 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands Operands This command has the f ollowing operands: Example T o display the port end-to-end mask on blade 2, .
1 po rtCf gE po rt 1-313 T elnet Com mands portCfgEport Enable or disable a port fr o m becoming an E_Port. Syntax portCfgEport [slotnumber/]portnumber, mode A v ailability Admin Descr iption This comma nd allows a user to enable/dis able a port from becoming an E_Port.
1 1-314 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands When no operands a re specified, the command reports a list of ports that ar e disabled fro m becoming E_Ports. Example T o disable blade 2 port 3 from becoming an E_Port: switch:admin> portCfgEport 2/3, 0 Committing configuration.
1 po rtCf gG po rt 1-315 T elnet Com mands portCfgGpor t Designates a port as a locked G_Port. Syntax portCfgEport [slotnumber/]portnumber, mode A v ailability Admin Descr iption This command enables a user to d esignate a port as a locked G_Port.
1 1-316 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands Example The follo wing exa mple configur es sblade 2, port 3 as a lock ed G_Po rt: switch:admin> portCfgGport 2/3, 1 done. See Als o portShow switchShow configure portCfgShow portnumber Specify the port number to be configured.
1 portCfgLon gDist ance 1-317 T elnet Com mands por tCfgLongDistance Configure a port to support lon g distance link s. Syntax portCfgLongDistance [slot/]port [, dis tance_level] [, VC_translation_lin.
1 1-318 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands level 1 long distance, and long f or level 2 long distan ce. In the switchShow output, the format is Lx , where x is the long distance level number , except for level 0, which is not displa yed in switchShow .
1 portCfgLon gDist ance 1-319 T elnet Com mands Limitations Since the total number of frame buf fers is limited in quad, when one of the ports in the quad is configured as a long distan ce port, all remaining ports must be level zero ports onl y (that is, none of the remaining ports in the quad can be a long distan ce port).
1 1-320 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands portCfgLpor t Lock a port as an L_PO R T . Syntax portCfgLport [slotnumber/]portnumber, lockmode[, privatemode] A v ailability Admin Descr iption Use this command t o designate a port as an L_PORT .
1 po rtCf gL po rt 1-321 T elnet Com mands Example T o configure switch blade 2 port 3 as a lock ed L_POR T: switch:admin> portCfgLport 2/3, 1 done. See Al so portShow switchShow configure lockmode Specify 1 to configur e the specified port as a locked L_POR T .
1 1-322 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands portcfgMcastLoopbac k Configure a port to receive multicast frames. Syntax portCfgMcastLoopback port , mode A v ailability Admin Descr iption Use this comma nd to configure a port to receive multicast frames.
1 por tcfgMcastLoo pback 1-323 T elnet Com mands ◆ The comment field of switchShow will show th at it is looped ba ck to itself like so: port 3: sw No_Light Loopback->3 ◆ The portFlags lin e of.
1 1-324 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands portCfgSho w Display port co nfigurati on settings. Syntax portCfgShow [slotnumber/][portnumber] A v ailability All users Descr iption Use this com mand to display the current configu ration of all ports.
1 portC fgShow 1-325 T elnet Com mands Operands This command h as the following operands: Example T o display the configuration settings of port 5 on blade 7 on a v4.
1 1-326 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands portCfgSpeed Configure the port speed level. Syntax portCfgSpeed [slotnumber/]portnumber, speed_level A v ailability Admin Descr iption Use this command to configur e the speed of a port to a particular level.
1 portC fgSpeed 1-327 T elnet Com mands Example T o configure the speed of blade 2, p ort 5 to 2 Gb/s: switch:admin> portCfgSpeed 2/5, 2 done. See Al so switchCfgSpeed portShow speed_level Specify the speed of a port. Th is operand is optional. V alid values are one of the follow ing: 0 Auto-sensin g mode.
1 1-328 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands portCfgT runkpor t Configure a port to be enabled or disabled for trunkin g. Syntax portCfgTrunkport [slotnumber/]portnumb er, mode A v ailability Admin Descr iption Use this command to configur e a port to be enabled or disabled fo r trunking.
1 po rt Cf gT run k po rt 1-329 T elnet Com mands Example T o enable blade 2, port 5 for trunking: switch:admin> portCfgTrunkport 2/5, 1 done. See Al so switchCfgTrunk portShow portCfgShow switchSh.
1 1-330 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands portDisable Disab le a sw itch port. Syntax portDisable [slotnumber/]portnumber A v ailability Admin Descr iption Use this comma nd to disable a switch port . If the port is connected to another switch, the fabric may reconfigure.
1 portD isab le 1-331 T elnet Com mands Example T o disable blade 2, port 4: switch:admin> portDisable 2/4 switch:admin See Al so portEnable portShow switchShow.
1 1-332 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands portEnable Enable a switch port. Syntax portEnable [slotnumber/]portnumber A v ailability Admin Descr iption Use this command to enable a switch port. If the port is connected to another switch, the fabric may reconfigure.
1 portEn ab le 1-333 T elnet Com mands Example T o enable port 4: switch:admin> portEnable 2/4 switch:admin See Al so portDisable portShow switchShow.
1 1-334 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands por tErrShow Display port error summary . Syntax portErrShow A v ailability All users Descr iption Use this command to display an err o r summary for all ports .
1 portErr Show 1-335 T elnet Com mands Example The following example shows an eight-port switch. Notice in the example below that port six has a high n umber of error s and should be examined: switch:.
1 1-336 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands portLEDT est Exercise the user port LEDs. Syntax portLEDTest [-npass count | -port port list ] A v ailability Admin Descr iption Use this command to exer cise the LEDs on a switch blade.
1 por tLogClear 1-3 37 T elnet Com mands portLogClear Clear the port log. Syntax portLogClear A v ailability Admin Descr iption Use this command to clear the port log . Y ou may want to clear the port log before triggering an activity so that the log displa ys only the activity related to that activity .
1 1-338 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands portLogDump Display th e port log withou t page breaks. Syntax portLogDump [count[, saved[, portid]]] A v ailability All users Descr iption Use this com mand to displ ay the port log, listin g all entries in the log without page breaks.
1 por tLogDump 1-3 39 T elnet Com mands Example T o display the port log: switch:admin> portlogdump 10 May 1 task event port c md args -------------------------------------- -------- 16:51:15.499 tShell ioctl 7 de 10f9bb90,0 16:51:15.499 tShell ioctl 8 de 10f9bb90,0 16:51:15.
1 1-340 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands portLogShow Display th e port log. Syntax portLogShow [ count [, saved, portid ]] A v ailability All users Descr iption Use this com mand to display th e port log; 22 entries are displayed at a time .
1 portLo gS ho w 1-341 T elnet Com mands Event Possible e vents are: star t disa b le enable ioct Tx Rx scn pst ate rejec bus y ctin ctout errlo g loopscn create deb ug nbr fsm sn fcin fcout read writ.
1 1-342 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands Cmd Command value descr iption depends on event type: ioctl Tx & Rx scn pst ate ctin ctout errlo g loopscn debug message frame payload size new state (see state c odes below) new physical state.
1 portLo gS ho w 1-343 T elnet Com mands Args The command arguments descripti on depends on event type: star t ioct Tx & Rx rejec t busyFC-PH busy reason ctin ctout errlog loopscn star t type: 0 =.
1 1-344 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands Ta b l e 1 - 2 3 Stat e Codes State Code Description 1 Online 2 Offline 3 Te s t i n g 4 Fa u l t y 5 E_P or.
1 portLo gS ho w 1-345 T elnet Com mands Ta b l e 1 - 2 6 Lip Reason Codes Ta b l e 1 - 2 5 Speed Negotiation States Speed Negotiation State Descriptio n ITIT star t negoti ation NM negotiate ma ster .
1 1-346 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands Operands This command has the f ollowing operands: Example The followi ng example show s a section of the port log with an E_Port coming online. The ELP and EFP exchanges ar e shown; a name service r equest was processed.
1 portLo gS ho w 1-347 T elnet Com mands 17:05:31.775 PORT Tx 2 40 02fffffd,00fffffd,0e08ffff,1 4000000 17:05:31.775 PORT debug 2 00c0ffee,00fd015c,14000000,0 0000001 17:05:31.777 PORT Rx 2 0 c0fffffd,00fffffd,0e080907 17:05:31.778 PORT Tx 3 40 02fffffd,00fffffd,0e09ffff,1 4000000 17:05:31.
1 1-348 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands portLoopbac kT est Run fun ctio na l te st of por t N- >N pa th.
1 por tLoop backT es t 1-349 T elnet Com mands At each pass, the f rame is cr eated fr om a dif ferent d ata type. If seven passes ar e req uested, seven differ ent data types ar e us ed in the test. If eight passes ar e requested, th e first seven frames use unique data types, and the eighth is the sa me as the first.
1 1-350 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands See Als o ramTest portRegTest centralMemoryTest cmiTest sramRetentionTest turboRamTest camTest statsTest fil.
1 portPerf Show 1-351 T elnet Com mands portPerfSho w Display port throughput perform ance in bytes, kilobytes, or megabyte s. Syntax portPerfShow [ interval ] A v ailability All users Descr iption Use this command to display throughput informat ion for all ports on the switch (8 or 16 colum ns depending o n the switch model) .
1 1-352 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands portRegT est Bit write/read test of th e ASIC SRAMs a nd registers.
1 portRegT est 1-353 T elnet Com mands Operands This command has the f ollowing operands: Example T o r un bit write/read test of the ASIC SRAMs and register s: switch:admin> portRegTest Running Port Register Test .
1 1-354 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands portRouteShow Display routing tables f or a port. Syntax portRouteShow [slotnumber/]portnumber A v ailabilit.
1 portRou teShow 1-355 T elnet Com mands Multicast routing table Shows mult icast fram e routing to the desti nation multicast group. Output format is: mcast_group_number: (mcast_group_id) ports_bitmap wher e mcast_group_number is the multicast group numb er .
1 1-356 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands Operands This command has the f ollowing operands: Example T o display the port routing tables f or blade 4,.
1 por tShow 1-357 T elnet Com mands portShow Display port s tatus. Syntax portShow [slotnumber/]portnumber A v ailability All users Descr iption Use this com mand to display sta tus info rmation for a po rt. Information varies with the switch model and port type.
1 1-358 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands portRegs Addres s of the port hardw are r egisters. portData Addres s of the port driver private data. portId 24-bit D_ID for port. portWwn Port W orldW ide Na me.
1 por tShow 1-359 T elnet Com mands Operands This command has the f ollowing operands: Overrun Buffer overr un interrupts. Suspended T ran smission suspen ded in terrupts. Parity_err Real Tx da ta parity error . 2ndary_parity_err Secondary Tx data parity error .
1 1-360 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands Example T o display the status f or a specified E_Port: switch:admin> portShow 2/15 portCFlags: 0x0 portFlags: 0x20001 PRESENT D ISABLED LED portType: 1.
1 portS tatsShow 1-361 T elnet Com mands portStatsShow Display port h ardware statistics. Syntax portStatsShow [slotnumber/]portnumber A v ailability All users Descr iption Use this comma nd to display port hardware statistics counters. Ta b l e 1 - 2 9 por tStatsShowHardw are Statistics stat_wtx 4-byte words transmitted.
1 1-362 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands fl_open Numb er o f OPN yx s ent. fl_opened Number of OPNyx received. fl_openfr Numb er o f OPN fr sent . fl_cls_idle CLS sent due to loop idle. fl_cls_rx CLS received w hen OPEN.
1 portS tatsShow 1-363 T elnet Com mands Operands This command has the f ollowing operand: slotnumber Specify the s lot number in an ED-12000 B switch. The slot number must be followed by a slash ( / ) and the port number . The ED- 12000B ha s a total of 10 slots counte d from 1 to 10.
1 1-364 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands Example T o display the basic set of statistics for blade 2, port 3: switch:admin> portStatsShow 2/3 stat.
1 po we rOf fLi stS et 1-365 T elnet Com mands po werOf fListSet Set slot power of f lis t or der Syntax powerOffListSet A v ailability Admin Descr iption Use this command to s et the physical p ower off slot order . The system available power is compar ed to the system demand power to determine if there is enough power to operate.
1 1-366 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands Example T o modify the po w er off list or der: switch12k:admin> powerOffListSet Slot Current POL ------------------- 10 1st 9 2nd 8 3rd 7 4th 4 5th 3 6th 2 7th 1 8th 1st slot to be powered off: (1.
1 po we rOf fLi stS ho w 1-367 T elnet Com mands po werOf fListShow Syntax powerOffListShow A v ailability All users Descr iption Use this com mand to display th e or der in which the ph ysical slots will be powered off. The sy stem available power is compared to the system demand power to determine if there is enough powe r to operate.
1 1-368 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands psSho w Display pow er supply status. Syntax psShow A v ailability All users Descr iption Use this comma nd to display the switch pow er supply status. The display format varies with the number of power su pplies pres ent.
1 psShow 1-369 T elnet Com mands See Al so fanShow tempShow.
1 1-370 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands ptdatashow Display port da ta structure. Syntax ptdatashow [ slot ]/ port Availability All users Descriptio n Use this command to display the ASIC data structure contents for the specified port.
1 ptphan tomshow 1-371 T elnet Com mands ptphantomsho w Display port routing tables. Syntax ptphantomshow [ slot /] port A v ailability All Users Descr iption Use this comma nd to display the ASIC routing table contents for the specified port. If the slot is not specified, then the slot specified with setslot is used.
1 1-372 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands ptpr opsho w Display port properties. Syntax ptpropshow [ slot /] port | [ slot ] -all A v ailability All Users Descr iption Use this command to display the ASIC po rt properties for the specified port.
1 ptr egs ho w 1-373 T elnet Com mands ptregshow Display ASIC port registers. Syntax ptpropshow [ slot ]/ port A v ailability All Users Descr iption Use this command to display the ASIC register contents for the specified port. If the slot is not specified, then the slot specified with setslot is used.
1 1-374 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands ptr outesho w Display port routing properties. Syntax ptrouteshow [ slot ]/ port A v ailability All Users Descr iption Use this command to display th e ASIC port routing properties for the specified port.
1 ptstatsshow 1-375 T elnet Com mands ptstatsshow Display port s tatistics properties. Syntax ptstatsshow [ slot ]/ port A v ailability All Users Descr iption Use this comman d to display the ASIC port sta tistic properties for the specified port. If the slot is not specified, then slot specified with setslot is used.
1 1-376 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands Example T o vie w port statistics properties on por t 1 on slot 8: switch:admin> portstatsshow 8/1 stat_w.
1 qloopAdd 1-3 77 T elnet Com mands qloopAdd Add a member to a QuickL oop. EMC does not support this comm and. Syntax qloopAdd " qloopnam e", " member;member " A v ailability Admin Descr iption Use this comma nd to add one or more members to an existing QuickLoo p.
1 1-378 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands qloopCreate Create a QuickLoop. EMC does not support this comm and. Syntax qloopCreate " qloopname ", " member;membe r " A v ailability Admin Descr iption Use this command to crea te a QuickLoop.
1 qlo opCr eat e 1-379 T elnet Com mands Example T o create two Quic kLoops, a single switch and one dual switch: switch:admin> qloopCreate "qlp1", "10: 00:00:60:69:00:60:11" sw.
1 1-380 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands qloopDelete Delete a QuickLoo p. EMC does not support this comm and. Syntax qloopDelete " qloopName " A v ailability Admin Descr iption Use th is co mman d to d elete a Qu ickLo op.
1 qloopRemove 1-381 T elnet Com mands qloopRemo ve Remove a member from a QuickLoop. EMC does not support this comm and. Syntax qloopRemove " qloopName ", " member;membe r " A v ailability Admin Descr iption Use th is co mmand to r emov e one or mo re membe rs f ro m a QuickLoo p.
1 1-382 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands Example T o remo ve member “ wwn2 ” from “ qlp1 ” : switch:admin> qloopRemove "qlp1", &.
1 qloopShow 1-383 T elnet Com mands qloopSho w Display Qu ickLoop in formatio n. EMC does not support this comm and. Syntax qloopShow [ pattern ][, mode ] A v ailability All users Descr iption Use this com mand to displa y QuickLoop con figuration in formation.
1 1-384 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands Operands The fol lowing opera nds are opti onal : Example T o display all Quic kLoops beginning with the let.
1 ram Tes t 1-385 T elnet Com mands ramT est Bit write and r ead test of SD RAMs in the switch. Syntax ramTest [ patternSize ] A v ailability Admin Descr iption Use this comm and to verify the address and data bus of the SDRAMs that serve as CPU memory in the switch.
1 1-386 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands Since the test r equires the o perating system to operate, and the operating syst em is loaded in t he same me mory , the tes t does not and cannot test all 16 MB o f the memory .
1 reboot 1-3 87 T elnet Com mands reboot Reboot the swi tch. Syntax reboot A v ailability Admin Descr iption The reboot comma nd will r eboot both logi cal switc hes and b oth CPs.
1 1-388 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands ro u t e H e l p Display routing hel p commands. Syntax routeHelp A v ailability Admin Descr iption Use this com mand to display routing h elp commands.
1 sav ec ore 1-389 T elnet Com mands sa v ecor e Save or r emove cor e files cr eated by daemons. Syntax savecore A v ailability Admin Descr iption Use this command to transfer (by wa y of F TP) or remove core files that were crea ted by daemons du ring signal processing such as SIGSEGV , SIGILL, etc.
1 1-390 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands sensorSh o w Display sen sor readings. Syntax sensorShow A v ailability All users Descr iption Use this command to display the current temperature, fan and power supply status and readings from sensors located on the switch .
1 sensor Show 1-391 T elnet Com mands Example The output of this command is dif ferent between v3.0 and v4.0. Below is an example of the output of this command fr o m v4.
1 1-392 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands setesdmo de Enable or dis able ESD mode. Syntax setesdmode [ mode | -show] A v ailability Admin Descr iption Use this command to enab le or disable ESD mode.
1 setgbicmo de 1-393 T elnet Com mands setgbi cmode Enable or disable GBIC mode. SSyn tax setgbi cmode [mode | -show] A v ailability Admin Descr iption Use this command to enable or disable the GBIC mod e. If the mode operand is 1 , GBIC mode is enabled; if the mode operand is 0, GBIC mode is disabled.
1 1-394 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands setmfgmode Enable or di sable Mfg mode. Syntax setmfgmode [ mode | -show] A v ailability Admin Descr iption Use this command to enable or disable Mfg mode.
1 setsfp mod e 1-395 T elnet Com mands setsfpmode Enable or di sable SFP mode. Syntax setsfpmode [ mode | -show] A v ailability Admin Descr iption Use this command to enable or disable the SFP mode. If the mode operand is 1, S FP mode is enabled; if the mode operand is 0, SFP mode is disabled.
1 1-396 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands setSlot Set the def ault slo t numb er for d iag nosti c co mman ds. Syntax setslot slot A v ailability Admin Descr iption Use this comma nd to set the default slot number for diag nostic commands.
1 setSplbM ode 1-397 T elnet Com mands setSplbMode Enable or dis able two port loopback. Syntax setSplbMode [mode | -show] A v ailability Admin Descr iption Use this command to enable or dis able SPLB mode. The mode i s saved in flash memory and stays in that mode until the next execution of setSplbMode .
1 1-398 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands Example T o enable or disable a tw o- port loopback: switch:admin> setSplbMode 1 Config update Succeded. SPLB mode is now 1 (Enabled). switch:admin> setSplbMode 0 Config update Succeded.
1 sfpShow 1-399 T elnet Com mands sfpShow Display serial ID S FP information . Syntax sfpShow [slotnumber/][portnumber] A v ailability All users Descr iption Use this com mand to displa y informatio n about seria l identificati on SFPs (als o known as modu le definition "4" SFPs ).
1 1-400 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands Example T o display SFP summary information and detailed information f or an SFP: switch12k:admin> sfpshow Area 0: id (id) Vendor: Serial No: Area 1: id (sw) Vendor: FINISAR CORP.
1 sfpShow 1-401 T elnet Com mands switch12k:admin> sfpshow 1/3 Identifier: 3 SFP Connector: 7 LC Transceiver: 050c402000000000 100,200_ MB/s M5,M6 sw Inter_dist Encoding: 1 8B10B Baud Rate: 21 (uni.
1 1-402 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands slotOff Disable a blade slot. Syntax slotOff slot A v ailability Admin Descr iption Use this comman d to disable a nonfa ulty blade unit while leavi ng the blade unit powered on.
1 slot On 1-403 T elnet Com mands slotOn Enable a blad e slot. Syntax slotOn slot A v ailability Admin Descr iption Use this com mand to reenable a blade un it that was previously disabled. Operand This command has the f ollowing operand: Example T o r eenab le bla de un it 3 : switch:admin> sloton 3 Slot 3 is being enabled.
1 1-404 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands slotpow erof f Power off a blade unit. Syntax slotPowerOff slot A v ailability Admin Descr iption Use this command to turn o ff the power to a blade un it.
1 slotpoweron 1-405 T elnet Com mands slotpow eron Power on a blade unit . Syntax slotPowerOn slot A v ailability Admin Descr iption Use this command to turn on the power to a blade unit. The slot must have a valid blade unit pr esent and the blade unit must be curr ently powered o ff.
1 1-406 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands slotShow Display slo t status. Syntax slotShow A v ailability All users Descr iption Use this co mmand to inventory a nd display th e current status o f each slot in the system.
1 slotShow 1-407 T elnet Com mands Operands None Example T o display a blade in ventory and status: switch:admin> slotshow Slot Blade Type ID Status --------------------------------- 1 UNKNOWN VACA.
1 1-408 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands See Als o chassisShow slotOn slotOff slotPowerOn slotPowerOff.
1 snmpM ibCa p Set 1-409 T elnet Com mands snmpM ibCa pSe t V iew an d mod ify options fo r configurin g SNMP MI B/T rap capability . Syntax snmpMibCapSet A v ailability Admin Descr iption Use this co mmand to turn on o r of f certain MIBs an d TRAPs.
1 1-410 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands spinFab T e st for Ca scaded s witch IS Ls. Syntax spinfab [-nmegs nmill][-ports list][-s etfail failmode] [.
1 spinFa b 1-411 T elnet Com mands Operands This command has the f ollowing operands: nmil The number of million f rames per port to execute this test. If omitt ed, the default value used is 100. This operan d is optional. ePortBeg First port to test, if omitted 0 will be used.
1 1-412 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands Examples This example is for v4.0. T o run spinFab on ports 0- 4: switch:admin> spinfab -nmegs 3 -ports 0-4 spinfab running... spinfab: Completed 3 megs, status: pa ssed.
1 spinFa b 1-413 T elnet Com mands 0x3f STATS_C3FRX 0x40 STATS 0x41 MBUF_STATE_ERR 0x42 FINISH_MSG_ERR 0x43 RXQ_RAM_PERR See Al so crossPortTest portLoopbackTest spinSilk setDbg.
1 1-414 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands spinSilk Run functional test of port-to-port path at maximum switch speed.
1 spinSilk 1-4 15 T elnet Com mands At each pass, the frame is created fr om a diffe rent data type. There ar e seven data types: If seven passes are r equested, the seven different data types ar e used in the test. If eight passes a re r equested, the first s even frames use unique data types, and the eighth is the same as the first.
1 1-416 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands The connections between pairs of M-to-M ports are c hosen to exercise the connections between as many ASICs as possible subject to the availabil ity of pairs of M-to-M ports.
1 spinSilk 1-4 17 T elnet Com mands Operands This command has the f ollowing operands: nmill Specify the number of mi llion fram es to send. The test w ill progr es s until the specified number of frames has been transmitted on each port. The default value for nmill is 10, so th e number of frames sent will be at leas t 10 millio n.
1 1-418 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands spdmode Specify the speed mode for the test. This parameter is only used for v3.0 an d v4.0 series based switches wher e it contr ols the speed at which ea ch port is o perated.
1 spinSilk 1-4 19 T elnet Com mands Example T o r un spinsilk on a switch: switch:admin> switchdisable switch:admin> spinsilk Running Spin Silk .
1 1-420 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands sramRetentionT est Run da ta retention test of the mi scellane ous SR AMs in A SIC.
1 sramRetention T es t 1-421 T elnet Com mands See Al so ramTest portRegTest centralMemoryTest cmiTest turboRamTest camTest statsTest filterTest portLoopbackTest spinSilk.
1 1-422 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands statsT e st Run a statisti cs counter diagno stic test. Syntax statsTest [-passcnt passcount][-ports list] A v ailability Admin Descr iption Use this command to verify the bloom statistics counter logic.
1 statsT est 1-4 23 T elnet Com mands Diagnostics When it detects failure(s), the subtest may r eport one or more of the following err or messages: DIAG-STSINIT DIAG-STSNULL DIAG-STSSID DIAG-STSXMIT D.
1 1-424 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands supportShow Display mu ltiple test results for custom er debugging.
1 suppor tShow 1-425 T elnet Com mands Example T o display switch information for deb ugging: switch:admin> supportShow 4/0, 15 version: Kernel: 2.4.2 Fabric OS: 4.0.0 Made on: Thu Oct 25 00:58:55 2001 Flash: Thu Oct 25 00:58:55 2001 BootProm: Unknown uptime: 11:46pm up 4:39, 3 users, load av erage: 1.
1 1-426 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands switchBeacon Set swit ch beac oning m ode on or off. Syntax switchBeacon [mode] A v ailability Admin Descr iption Use this com mand to set the switch beaco ning mode on (if the operand is 1) or off (if the oper and is 0).
1 switchCfgSpeed 1-427 T elnet Com mands switchCfg Speed Configure all ports of the switch to a particula r speed level. Syntax switchCfgSpeed speed_level A v ailability Admin Descr iption Use this command to configur e the speed of all the ports on a switch to a particula r level.
1 1-428 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands switchCfgT r unk Enable or disable trunking on all the ports of a s witch. Syntax switchCfgTrunk [mode] A v ailability Admin Descr iption Use this com mand to enable or disable trunkin g on all the po rts of a switch.
1 switch diag 1-429 T elnet Com mands switchdiag Run dia gnosti cs on aD S-32B 2 switch. Syntax switchdiag A v ailability Admin Descr iption Use this comma nd to run a suite of diagnostics tests on the specified switch. T o run this command yo u must insta ll loopback plu gs on every port.
1 1-430 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands passed. Test return status: 0 CentralMemoryTest Running centralmemorytest ............ passed. Test Complete: "centralmemorytest" Pas s 1 of 1 Duration 0 hr, 0 min & 19 sec (0:0:19: 611).
1 switchd iagshor t 1-4 31 T elnet Com mands switchdiagshort Run dis agnostics on a DS- 32B2. Syntax switchdiagshort A v ailability Admin Descr iption Use this comma nd to run a suite of diagnostics tests on the specified switch. T o run this command yo u must insta ll loopback plu gs on every port.
1 1-432 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands passed. Test return status: 0 CentralMemoryTest Running centralmemorytest ............ passed. Test Complete: "centralmemorytest" Pas s 1 of 1 Duration 0 hr, 0 min & 19 sec (0:0:19: 611).
1 switchD isa ble 1-4 33 T elnet Com mands switchDisable Disable the switch. Syntax switchDisable A v ailability Admin Descr iption Use this command to disable the switch. All Fibr e Channel ports are taken off line; if the switch was part o f a fabric, the remaining switches reconfigure.
1 1-434 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands switchEnable Enable the switch. Syntax switchEnable A v ailability Admin Descr iption Use this com mand to enable the switch. A ll Fibre Channel ports that passed POST ar e enabled.
1 switc hName 1-435 T elnet Com mands switchName Display or set s witch name. Syntax switchName [" newName" ] A v ailability All users (displa y) Admin ( set) Descr iption Use this com mand without an op erand to display the current switch name.
1 1-436 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands switchReboot Halt and bring d own the operationa l switch. Syntax switchReboot A v ailability Admin Descr iption Use this com mand to reboot the operational sw itch withou t disrupting the other sw itch in the ED -12000B ch assis.
1 switc hSho w 1-437 T elnet Com mands switchShow Display sw itch and port status. Syntax switchShow A v ailability All users Descr iption Use this com mand to display sw itch and port status information. Informatio n may vary by sw itch model . Below is the info rmation provided.
1 1-438 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands The switch summary is followed by one line per port: port number Port n umber .
1 switc hSho w 1-439 T elnet Com mands Operands None comment The comment field may be blank, or it may display: ◆ Disabled — port is disabled ◆ Bypassed — port is bypassed (loop only) ◆ Loop.
1 1-440 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands Example The follo wing e xample sh ows an ED-12000B: switch12000:admin> switchshow switchName: switch12000 switchType: 10.
1 switc hSho w 1-441 T elnet Com mands The foll owing e xample s hows a DS-32B2: switch3900:admin> switchshow switchName: switch3900 switchType: 12.
1 1-442 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands See Also switchDisable switchEnable switchName.
1 switchS hutdo wn 1-4 43 T elnet Com mands switchShutdown Halt the oper atio nal swi tch. Syntax switchShutdown A v ailability Admin Descr iption This comma nd halts the switch operation wit hout disrupting the other switch in the ED-12 000B chassis.
1 1-444 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands switchStar t Initialize the sw itch to operatio nal. Syntax switchStart A v ailability Admin Descr iption This com mand initiali zes a logica l switch witho ut disrupting the other switch in the ED-12 000B chassis.
1 switch Status P o licySet 1-445 T elnet Com mands switchStatusPolic ySet Set the policy parameters tha t determine the overall s witch status. Syntax switchStatusPolicySet A v ailability Admin Descr iption Use this comma nd to set the policy parameters for calcula ting the overall statu s of the switch enclo sure.
1 1-446 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands status to DOWN. If two ports were faulty , then this contributor would set the overall sw itch status to DOWN .
1 switch Status P o licySet 1-447 T elnet Com mands Example Notice that in the following example, the only parameters modified are the n umber of Missing SFPs allowed before the s tatus of the switch changes to MARGINAL and DOWN .
1 1-448 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands switchStatusPolic yShow Display th e policy parameters that determine the overall sw itch status. Syntax switchStatusPolicyShow A v ailability All users Descr iption Use this command to view the current policy parameters set for the switch.
1 switch StatusP olicyShow 1-449 T elnet Com mands Example T o display the switch status policy: switch:admin> switchStatusPolicyShow The current overall switch status poli cy parameters: Down Marg.
1 1-450 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands switchStatusSho w Display th e overall status of the switch. Syntax switchStatusShow A v ailability All Users Descr iption Use this command to display the overall status of the switch.
1 switchS tatus Show 1-451 T elnet Com mands Example There ar e t wo examples below . The first shows a switch with a status of MARGI NAL, the sec ond shows th e sa me swit ch afte r all the err ors have been fixed.
1 1-452 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands switchuptime Display the amount of time the switch has been operating. Syntax switchuptime A v ailability All users Descr iption Use this comma nd to display the current time and the amount of time the switch ha s been operatio nal.
1 syslog dIpAdd 1-4 53 T elnet Com mands syslogdIpAdd Add the IP a ddress o f a syslog daemon. Syntax syslogdIpAdd IPaddress A v ailability Admin Descr iption Use this command to add the IP addr ess of a syslog daemo n, that is, the IP addr ess of the server that is running the syslogd pr ocess.
1 1-454 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands syslogdIpRemo ve Remove the IP addre ss of a sys log daemon.
1 syslogdIp Show 1-455 T elnet Com mands syslogdIpSho w Display a ll syslog d aemon IP ad dresses. Syntax syslogdIpShow A v ailability All users Descr iption Use thi s command to display a ll syslog d aemon I P addresses in the configuration database.
1 1-456 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands systemtest Run dia gnosti cs on a sw itch blade. Syntax systemtest [-slot slot ] A v ailability Admin Descr iption Use this comma nd to run a suite of diagnostics tests on the specified switch blad e.
1 systemt est 1-457 T elnet Com mands Example T o r un a suite of diagnostics on blade 7: switch:admin> systemtest -slot 7 Testing slot: 7, user ports: 3 2 1 0 7 6 5 4 11 10 9 8 15 14 13 12 PortRegTest Running Port Register Test .... passed. Test Complete: "portregtest" Pass 1 of 1 Duration 0 hr, 2 min & 23 sec (0:2:23: 443).
1 1-458 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands tempShow Display tem perature readings. Syntax tempShow A v ailability All users Descr iption Use this comma.
1 timeOut 1-459 T elnet Com mands timeOut Set or clear the idle T elnet connectio n time-out value. Syntax timeOut [ timeval ] A v ailability All users (displa y) Admin ( show/se t) Descr iption Use this command with no operan ds to display the curr ent telnet timeout value.
1 1-460 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands topolog y Show Display th e unicast fabric topology . Syntax topologyShow [ domainnumber ] A v ailability All users Descr iption Use this com mand to display th e fabric topology , as it appears to the local s witch.
1 topologyShow 1-461 T elnet Com mands Operand This command has the f ollowing operand: Out Port: Area number of the port that incoming f rame will be forwarde d to, in or der to r each the destination domain. Use the switchshow command to view the area numbers for the switch.
1 1-462 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands Examples T o display the unicast fabric topology: switch:admin> topologyShow 2 domains in the fabric; Loc.
1 trac kChang esSet 1-463 T elnet Com mands trackC hangesSet Enable configurin g of T rack Ch anges feature. Syntax trackChangesSet [ mode ], [ snmptrapmo de ] A v ailability Admin Descr iption Use this comm and to e nab le or dis able the T r ack C han ges fe ature.
1 1-464 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands Example The following example shows how to use this command in v4.
1 trac kChang esShow 1-465 T elnet Com mands trackC hangesSho w Display sta tus of T rac k Changes feature. Syntax trackChangesShow A v ailability All users Descr iption Use this com mand to display sta tus of the T rack Changes fea ture. It shows if the featur e is turned on or of f and if SNMP trap a re generated.
1 1-466 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands trunkDebug Debug a trunk link failure. Syntax trunkDebug port1 , port2 A v ailability Admin Descr iption Use this com mand to debu g a trunk link failu re.
1 trunk Show 1-467 T elnet Com mands trunkShow Display trunki ng inform ation. Syntax trunkShow A v ailability All users Descr iption Use this com mand to display trunki ng informati on.
1 1-468 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands turboRamT est Run the turbo S RAM logic test for 2 Gb ASICs. Syntax turboRamTest [ passcount ] A v ailability Admin Descr iption This command verifies the on-chip SRAM lo cated in the 2 Gb ASIC using the T urbo -Ram BIST cir cuitry .
1 turboRam T es t 1-469 T elnet Com mands Example T o ex ecute this test: switch:admin> turboRamTest Running Turbo RAM Test ........ passed . Diagnostics When it detects failure(s), the subtest may r eport one or more of the following err or messages: DIAG-W TEST — Me mory f ill operat ion failed.
1 1-470 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands uptime Display len gth of time the system has been operationa l.
1 uRou teCo nf ig 1-471 T elnet Com mands uRouteConf ig Configure a static route. Syntax uRouteConfig InArea , Domain , OutArea A v ailability Admin Descr iption Use th is co mmand to c onfigu r e sta tic r ou tes. A stat ic r ou te is assigned a specific path; the pa th does not change with a topology change unless the path beco mes unavailable.
1 1-472 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands Examples T o configure a static route f or all traf fic coming in from port 1 and addressed to domain 2 to go th rough port 5: switch:admin> uRouteConfig 1,2,5 done.
1 uRouteRemov e 1-473 T elnet Com mands uRouteRemo ve Remove a s tatic r oute. Syntax uRouteRemove InArea, Domain A v ailability Admin Descr iption Use this com mand to remove a configured static route. When this command is issued, the route to Domain for InArea may or may not change.
1 1-474 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands uRouteSho w Display un icast routing info rmation. Syntax uRouteShow [ slotnumber/ ] [ portnumber ], [ domai.
1 uRouteShow 1-475 T elnet Com mands The informatio n provided by this comm and should match what is provided by port RouteShow and topologyShow . Operands This command has the f ollowing operands: Hops: Maximum number of hops r equired to reach the destination domain.
1 1-476 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands Examples The first example disp lays the routing info rmation of al l the active ports, The second comma nd .
1 versio n 1-477 T elnet Com mands ver s i o n Display firmw are version info rmation. Syntax version A v ailability All users Descr iption Use this com mand to displa y firmware version inform ation and bu ild dates.
1 1-478 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands Example T o display f irmware v ersion information on an ED-12000B: switch12k:admin> version Kernel: 2.4.2 Fabric OS: v4.0.0 Made on: Fri Feb 1 23:02:08 2002 Flash: Fri Feb 1 18:03:35 2002 BootProm: 3.
1 wwn 1-479 T elnet Com mands wwn V iew a switch WWN . Syntax wwn A v ailability All users Descr iption Use this com mand to display th e WWN of a switch. A ll switches have a numeric ad dress that is the unique Fibre Channel add ress used for communicating with the switch.
1 1-480 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands zone Add Add a member to the zo ne. Syntax zoneAdd " zoneName", "member/member " A v ailability Admin Descr iption Use this command to add o ne or more m embers to an existing zone.
1 zoneCreate 1-4 81 T elnet Com mands zone Create Create a zone. Syntax zoneCreate " zoneName", "member/member " A v ailability Admin Descr iption Use this command to create a new zone.
1 1-482 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands Specify a Q uickLoop A L_P A as a QuickLoo p name fol lowed by a li st of AL_P As, for example "qloop1[01,02]".
1 zoneCreate 1-4 83 T elnet Com mands Operands This command has the f ollowing operands: Example: T o create three zones using a combination of port numbers and zone aliases: switch:admin> zoneCrea.
1 1-484 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands zone Delete Delete a zone. Syntax zoneDelete " zoneName" A v ailability Admin Descr iption Use this command to delete a zone. This comm and r equir es a Zonin g license .
1 zoneHelp 1-4 85 T elnet Com mands zoneHe lp Display hel p informat ion on zon e commands . Syntax zoneHelp A v ailability All users Descr iption Use th is co mmand t o dis play help info rmatio n on zone co mman ds.
1 1-486 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands cfgClear Clear all zone configurations cfgDisable Disable a zone configuration cfgEnable Enable a zone confi.
1 zoneRemov e 1-487 T elnet Com mands zoneRemo ve Remove a member fr om a zone. Syntax zoneRemove "zoneName", "member;member" A v ailability Admin Descr iption Use this command to r emove one or mor e members fr om an existing zone.
1 1-488 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands zoneSho w Display z one informati on. Syntax zoneShow ["pattern"], [, mode] A v ailability All users Descr iption Use this com mand to displa y zone config uration inform ation.
1 zoneShow 1-489 T elnet Com mands Example T o show all zones beginning with the letters "A" thruogh "C": switch:admin> zoneShow "[A-C]*" zone: Blue_zone 1,1; array1; .
1 1-490 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual T elnet Commands.
License T elnet Commands 2-1 2 Invisible Body T ag This chapter sum marizes the com mands that a re only available with a license key . ◆ Zoning Commands ...................... ........... ................. ........... ............... 2-2 ◆ Extended Fabric Comman d .
2 2-2 EMC Connectr ix DS-32B2 and ED-12000B Fabric O S Ref erence Manual Lice nse T elnet Comman ds Zoning Commands The following com mands are available wit h the purchase of a Zoning license key .
2 Zoning Commands 2-3 Licens e T elnet Comman ds cfgDisable Disable a zone configuration. cfgEnable Enable a zone configuration. cfgSave Save zone configurations i n flash memor y .
2 2-4 EMC Connectr ix DS-32B2 and ED-12000B Fabric O S Ref erence Manual Lice nse T elnet Comman ds Extended F abric Command The followin g comman d is available wi th the purchase of a Extended Fabrics license key .
2 Fa br ic Watc h Co m ma n ds 2- 5 Licens e T elnet Comman ds F abr ic W atch Commands The following commands ar e availab le with the purch ase of a Fabric W a tch license k ey .
2 2-6 EMC Connectr ix DS-32B2 and ED-12000B Fabric O S Ref erence Manual Lice nse T elnet Comman ds T r unking Commands The following commands ar e availab le with the pur chase of a T runki ng li cen se ke y .
2 Perf o rmanc e Monitor ing Co mmands 2-7 Licens e T elnet Comman ds P erf or mance Monitoring Commands The following commands ar e availab le with the pur chase of an Advanced Performance Monitoring license key .
2 2-8 EMC Connectr ix DS-32B2 and ED-12000B Fabric O S Ref erence Manual Lice nse T elnet Comman ds.
Fabr ic OS V er sion Co mpar ison 3-1 3 Invisible Body T ag This chapter summarizes the commands available in v3 .0 and v4.0. ◆ Command Dif fer ences Between V ersions.
3 3-2 EMC Connectr ix DS-32B2 and ED-12000B Fabric O S Ref erence Manual Fabric OS V er sion Compariso n Comm and D ifferences Between V er sions This table pr ovides a list of which commands ar e available in v3.0 and in v4.0. It also pr ovides notes on dif feren ces that may exist for a particular com mand between versions.
3 Command Dif ferences Between V ers ions 3-3 Fabric OS V ersio n Comparison bsn Y es No N ot suppor ted in v4.0. Functional ity was replaced by chassisshow command in v4.
3 3-4 EMC Connectr ix DS-32B2 and ED-12000B Fabric O S Ref erence Manual Fabric OS V er sion Compariso n crossPortTest Y es Y e s New operands in v4.0 dataTypeShow Ye s Ye s date Ye s Ye s diagClearError Ye s Ye s diagCommandShow No Y es New command f or v4.
3 Command Dif ferences Between V ers ions 3-5 Fabric OS V ersio n Comparison errShow Ye s Ye s fabricShow Ye s Ye s fabStatsShow Ye s Ye s fanDisable No Y es New comm and f or v4.0 fanEnable No Y es New comm and f or v4.0 fanShow Ye s Ye s faStatsShow Y es No N ot suppor ted in v4.
3 3-6 EMC Connectr ix DS-32B2 and ED-12000B Fabric O S Ref erence Manual Fabric OS V er sion Compariso n fwConfigure Y es Y es Ne w En vironmenta l Classe s in v4.0 fwFruCfg No Y es New comm and f or v4.0 fwHelp Ye s Ye s fwMailCfg Ye s Ye s fwSetToCustom Ye s Ye s fwSetToDefault Ye s Ye s fwShow Y es Y es Outp ut modified in v4.
3 Command Dif ferences Between V ers ions 3-7 Fabric OS V ersio n Comparison ipAddrSet Y es Y e s This command has un ique parameters based on switch type ipAddrShow Y es Y e s This command dis plays unique information based o n switch type licenseAdd Ye s Ye s licenseHelp Ye s Ye s licenseIdShow No Y es New comm and f or v4.
3 3-8 EMC Connectr ix DS-32B2 and ED-12000B Fabric O S Ref erence Manual Fabric OS V er sion Compariso n msPlCapabilityShow Y es No Renamed in v4.0 to the msCapability Show command msPlClearDB Ye s Ye s msPlMgmtActivate Ye s Ye s msPlMgmtDeactivate Ye s Ye s msTdDisable Ye s Ye s msTdEnable Ye s Ye s msTdReadConfig No Y es New comm and f or v4.
3 Command Dif ferences Between V ers ions 3-9 Fabric OS V ersio n Comparison perfDelEEMonitor Y es Y es Addition o f the slot operand perfDelFilterMonitor Y es Y es Addition o f the slot operand perfH.
3 3-10 EMC Connectr ix DS-32B2 and ED -12000B Fabr ic OS Reference Manual Fabric OS V er sion Compariso n portPerfShow Ye s Ye s portRegTest Y es Y e s New operands for v4.
3 Command Dif ferences Between V ers ions 3-11 Fabric OS V ersio n Comparison qlShow Y es No N ot suppor ted in v4.0 qlStatsShow Y es No N ot suppor ted in v4.
3 3-12 EMC Connectr ix DS-32B2 and ED -12000B Fabr ic OS Reference Manual Fabric OS V er sion Compariso n switchCfgTrunk Ye s Ye s switchDisable Ye s Ye s switchEnable Ye s Ye s switchName Ye s Ye s s.
3 Command Dif ferences Between V ers ions 3-13 Fabric OS V ersio n Comparison uRouteConfig Y es Y e s Addition of the area para meter uRouteRemove Y es Y e s Addition of the area para meter uRouteShow Y es Y e s Addition of the slo t operand version Y es Y es Outp ut modified in v4.
3 3-14 EMC Connectr ix DS-32B2 and ED -12000B Fabr ic OS Reference Manual Fabric OS V er sion Compariso n.
Fabr ic and Sw itch M anagem ent 4-1 4 Invisible Body T ag This chapter explains th e differ ent methods used to manage a SAN for DS-3 2B2 and ED-12 000B swit ches. ◆ Overview .......... ................. ............ ................. ........... .
4 4-2 EMC Connectr ix DS-32B2 and ED-12000B Fabric O S Ref erence Manual F abric and Switch Management Ov er view The DS-32B2 a nd ED-12000B sw itches can be m anaged using several local and remote access me thods.
4 User Access L ev el 4-3 Fabric and Switch Management User Acc ess Lev e l There are two levels of us er access for the DS-32 B2 and ED-12000B switches . ◆ Admin ◆ User In Fabric OS v4.0, eac h user access level can have the following number of simultaneous logins: In Fabric OS v3.
4 4-4 EMC Connectr ix DS-32B2 and ED-12000B Fabric O S Ref erence Manual F abric and Switch Management F abr ic OS Command Line Interf ace The Fabric OS command line interface (CLI) accessed thro ugh telnet or serial console pr ovides the user with the full range of management capabilit y on a DS-32B2 an d ED-12000 B switch.
4 We b To o l s 4-5 Fabric and Switch Management We b To o l s W eb T ools provides a graphical in terface that allows th e administrato r to monitor and manag e entire fa brics and individual switches and ports f rom a standard workstation. It is an optio nally licensed product that r uns on Fabric OS.
4 4-6 EMC Connectr ix DS-32B2 and ED-12000B Fabric O S Ref erence Manual F abric and Switch Management Fa b r i c Wat c h Fabric W atch software monitors the performance and stat us of Fibre Channel n etworks and DS- 32B2 and ED -12000B s witches, and can alert SAN managers when pr oblems arise.
4 Management Ser ver 4-7 Fabric and Switch Management Management Se r ver The Management Server allows an Storage Ar ea Network (SAN) manageme nt application to retrieve and administer the fabric an d interconnect elements such as switches, servers, and storage devices.
4 4-8 EMC Connectr ix DS-32B2 and ED-12000B Fabric O S Ref erence Manual F abric and Switch Management.
Cont r ol P roc esso r C omm ands 5-1 5 Invisible Body T ag This chapter lists the commands ava ilable when logg ed into the Active CP a nd Standby CP in an ED-12000B. ◆ Active CP Commands ...................... ................. ............ ......
5 5-2 EMC Connectr ix DS-32B2 and ED-12000B Fabric O S Ref erence Manual Control Proce ssor Com man ds Activ e CP Command s When logged into the Active CP , the full suite of commands are supported (subject to which license keys are installed). When logged in to the A ctive CP , most commands are still specific to a single logical switch.
5 Standby CP Co mmands 5-3 Contr ol Pr oces sor Commands Standb y CP Commands The following commands ar e supported when logged in to the Standby CP . Ta b l e 5 - 1 ED-12000B Standby CP Com mands Command N otes date Prin t/set the system date an d time.
5 5-4 EMC Connectr ix DS-32B2 and ED-12000B Fabric O S Ref erence Manual Control Proce ssor Com man ds.
Custom er Suppor t A-1 A nvisible Body T ag This appendix reviews the EM C process for detecting and resolving software problems, and provides essenti al question s that you sh ould answer before contacting the EMC Customer Support Center . This appendix covers th e following to pics: ◆ Overview of Detecting and Resolving Pro blems .
A A-2 EMC Connectr ix DS-32B2 and ED-12000B Fabric O S Ref erence Ma nual Customer Support Ov er view of D etecting and Resol ving Pr oblems EMC software pr oducts are supported dir ectl y by the EMC Customer Support Center in the United States . EMC uses th e following process to resolve customer problems wit h its software products (Figure A-1).
A Tr oubleshooting the P roblem A-3 Customer Su pport T roubl eshooti ng the Pr oblem Please perform the r elevant diagnostic steps before yo u contact the EMC Customer Support Center: 1. Re ad t he do cu ment ati on ca reful ly . 2. Reconstruct the events lea ding up to the problem and describe them in writin g.
A A-4 EMC Connectr ix DS-32B2 and ED-12000B Fabric O S Ref erence Ma nual Customer Support Bef ore Calling the Customer Suppor t Center Have the follo wing informatio n available bef ore calling the C.
A Docu menting the Problem A- 5 Customer Su pport Documenting the Pr oblem If the EMC Customer S upport Center req uests information regar ding the problem, please document it com pletely , making sur.
A A-6 EMC Connectr ix DS-32B2 and ED-12000B Fabric O S Ref erence Ma nual Customer Support Reporting a New Pr oblem For a new problem, please provide the following i nformation: ❑ Release level of t.
A Sending P roblem Docu mentatio n A-7 Customer Su pport Sending Problem Documentatio n Use on e of the fo llowi ng metho ds to sen d docu menta tion of th e problem to the EMC Cus tomer Support Center: ◆ Email ◆ FT P ◆ U.
A A-8 EMC Connectr ix DS-32B2 and ED-12000B Fabric O S Ref erence Ma nual Customer Support.
EMC Con nectrix DS-32B 2 and ED-1200 0B Fabric OS Reference Manual g-1 Glossar y The terms in the glo ssary relate to the sw itch and Fibre Channel connections. Many of these terms ar e used in this manual. Number s 8b/10b En coding An encoding sch eme that conv erts each 8-bit byt e into 10 bits.
g-2 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual Glossa r y Alias Address Identifier An address identifier recogn ized by a port in addition to its st andard identifier . An alias address identif ier may be shared by multiple ports.
EMC Con nectrix DS-32B 2 and ED-1200 0B Fabric OS Reference Manual g-3 Glossar y BB_Credit Buffer -to-buffe r credit. The number of frames that can be transmitted to a directly connected r ecipient or withi n an arbitrated loop. Determined by the number of receive buf fers available.
g-4 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual Glossa r y Buf fer to Buffer Flo w Control Management of the frame transmi ssion rate in either a point-to -point topology o r in an arbitrated lo op.
EMC Con nectrix DS-32B 2 and ED-1200 0B Fabric OS Reference Manual g-5 Glossar y Community (SNMP) A relationship between a group of SNMP managers an d an SNMP agent, in which authen tication, access control, and proxy characterist ics ar e defined. See also SNMP .
g-6 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual Glossa r y D Data W ord T y pe of transmission word that occurs w ithin frames. The frame header , data field, and CRC all consist of da ta words. See a lso Frame , Order ed S et , and T r ansmis sion Word .
EMC Con nectrix DS-32B 2 and ED-1200 0B Fabric OS Reference Manual g-7 Glossar y DTE P ort A data terminal equipment port cap able of interfacing to a transmission circuit through a connection to a DCE (d ata communications equipment) port.
g-8 EMC Connec trix DS-3 2B2 and ED-12000B Fab ric OS Reference Manual Glossa r y ESN Enterprise Storage Network. A storage netwo rk implementation that integrates products, technolo gy , and services.
EMC Con nectrix DS-32B 2 and ED-1200 0B Fabric OS Reference Manual g-9 Glossar y FCP Fib re C hann el Pr otocol. Map ping of pr oto cols onto the Fi br e Chan nel standar d prot ocols. For example, SCSI FCP maps SCSI-3 onto Fibr e Channel. FC-PH-1, 2, 3 The Fibre Channel Ph ysical and Sign alling Interf ace standards defined by ANSI.
g-10 EMC Connectr ix DS-32B2 and ED -12000B Fabr ic OS Reference Manual Glossa r y FLOGI Fabric Login. The pr ocess by which an N_Por t determines whether a fabric is pres ent, and if so, exchanges se rvice parameters with it. See also PL OGI. FL_P ort Fabric loo p port.
EMC Con nectrix DS-32B 2 and ED-1200 0B Fabric OS Reference Manual g-11 Glossar y Gatew ay Har dware that connects incom patible network s by providing translation for both hardw are an d softwar e. For example, an A TM gateway can be used to connect a Fibre Channel link to an A T M connection.
g-12 EMC Connectr ix DS-32B2 and ED -12000B Fabr ic OS Reference Manual Glossa r y I Idle Continuous tran smission of an ordered set over a Fibre Channel lin k when no data is bein g transmitte d, to keep the link active an d maintain bit , byte, and word synchronization .
EMC Con nectrix DS-32B 2 and ED-1200 0B Fabric OS Reference Manual g-13 Glossar y L L_P ort Loop port. A node port (NL_Port) or fabric po rt (FL_Port) that has arbitrated lo op capabilities. An L_Port can be in one of two modes: • Fabric mode: Conn ected to a port that is not loop ca pable, and using fabric protocol.
g-14 EMC Connectr ix DS-32B2 and ED -12000B Fabr ic OS Reference Manual Glossa r y Multicast The transmissio n of data from a single source to multiple specified N_Ports (as opposed to all the ports on the network). Se e also Broad cast and Unicas t .
EMC Con nectrix DS-32B 2 and ED-1200 0B Fabric OS Reference Manual g-15 Glossar y P Pack et A set of info rmation tra nsmitted across a network. S ee also Frame . Participating Mode A mode in which a n L_Port in a lo op has a valid AL_P A and can arbitrate, se nd frames, and retransmit received tran smissi ons.
g-16 EMC Connectr ix DS-32B2 and ED -12000B Fabr ic OS Reference Manual Glossa r y Priv ate NL_P ort An NL_Port that com municates only w ith other private NL_Ports in the same loop and does no t log in to the fabric. Protocol A defined method a nd a set of standar ds for communicati on.
EMC Con nectrix DS-32B 2 and ED-1200 0B Fabric OS Reference Manual g-17 Glossar y Route As applies to a fabric, the communicatio n path between two switches . May also apply to the specific pa th taken by an indi vidual frame, from source to destinatio n.
g-18 EMC Connectr ix DS-32B2 and ED -12000B Fabr ic OS Reference Manual Glossa r y SI Sequ ence init iati ve. SID/DID S ource identifier/destinatio n identifier . S_ID is a 3-byte field in the frame header that is used to indicate the address iden tifier of the N_Port fr om which th e frame was s ent.
EMC Con nectrix DS-32B 2 and ED-1200 0B Fabric OS Reference Manual g-19 Glossar y T e rminal Ser ial Port The lower serial port on the CP car d. Receives e rror messages. Ca n be used to connect the CP car d to a computer terminal. Has a DB-9 connector wir es as a ttyS0 DTE device, and can be connected by s erial cable to a DCE d evice.
g-20 EMC Connectr ix DS-32B2 and ED -12000B Fabr ic OS Reference Manual Glossa r y ULP Upper-level Protocol. Th e protocol that runs on top of Fibre Chan nel. T y pical upper-level protocols are SCSI, IP , HIPPI, and IPI. ULP_T OV Up per -le vel t ime- out val ue.
EMC Con nectrix DS-32B 2 and ED-1200 0B Fabric OS Reference Manual g-21 Glossar y Zone Schemes The level of zoning granularity selected. For example, zoning may be done by switch/port, WWN, or a mixture . See also Zone Configuration . Zone Set See Zone Configuratio n .
g-22 EMC Connectr ix DS-32B2 and ED -12000B Fabr ic OS Reference Manual Glossa r y.
EMC Con nectrix DS-32B 2 and ED-1200 0B Fabric OS Reference Manual i-1 A agtcfgDefault 1-8 agt cfgSe t 1-11 agtcfgSh ow 1-1 5 aliasDele te 1-18 alias Join 1- 19 alias Purge 1-21 alias Show 1-22 B back.
EMC Connectr ix DS-32B2 and ED -12000B Fabr ic OS Reference Manual i-2 Index F fabS tatsSh ow 1-146 fanDisable 1-147 fanEnable 1-148 fanS how 1-149 fastboot 1-150 fazo neAd d 1-1 51 fazon eCreate 1- 1.
i-3 EMC Con nectrix DS-32B 2 and ED-1200 0B Fabric OS Reference Manual Inde x portLogDump 1-338 portLogShow 1-340 portLoopbackT est 1-348 portPerfShow 1-351 portRegT est 1-352 portRouteShow 1-354 port.
EMC Connectr ix DS-32B2 and ED -12000B Fabr ic OS Reference Manual i-4 Index.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il EMC ED-12000B è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del EMC ED-12000B - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso EMC ED-12000B imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul EMC ED-12000B ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il EMC ED-12000B, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del EMC ED-12000B.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il EMC ED-12000B. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo EMC ED-12000B insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.