Manuale d’uso / di manutenzione del prodotto STM150 del fabbricante 3M
Vai alla pagina of 12
INSTR4089 1006 Owner’s Manual This manual is for the installation, operation, and maintenance of the ScaleGard ™ PLUS 2 Water Treatment Systems STM150 TSR150 ™ Installer please leav e manual with end user .
SAFETY INFORMATION CAUTION IMPORTANT NOTES Read, understand, and follow all safety information contained in these instructions prior to installation and use of the CUNO Foodservice STM150/TSR150 ScaleGard™ PLUS 2 W ater T reatment Systems . Retain these instructions for future reference.
Contents Installation Requirements Space Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Feedwater Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Electrical Requirements .
Important: Installation Requirements To reduce the risk associated with property damage due to water leakage: • Installation must comply with existing state or local plumbing codes; • Read and follow Use Instructions before installation and use of this system.
m e t s y S O R 0 5 1 M T S s u l P v e B s m e t s y S R S T y l p p u S r e t a W e c i v r e S o T k n a T O R e v l a V k c e h C k n a T l a u n a M e v l a V e n i L r e t a W O R " 8 / 3 .
Installation Procedure To reduce the risk associated with property damage due to water leakage: • Installation must comply with existing state or local plumbing codes; • Read and follow Use Instructions before installation and use of this system.
The water pressure in the tank will increase as the tank fills with water. When the pressure in the tank reaches approxi- mately 80 psi (552 kPa) the filter system shuts off. When water is drawn from the tank and the pressure drops to approximately 60 psi (414 kPa), the filter system will automatical- ly turn on.
Start-Up Procedure 1. Check air pressure in the storage tank, Refer to Storage Tank Installation. (page 6) 2. Close all water valves (5) in the system. (page 4) 3. Open water supply valve at the connection to the main water feed and the inlet water valve at the unit.
TDS Reduction Filter (M) Replacement Procedure [annually] 1. De-pressurize the system as instructed above. 2. Locate the TDS reduction filter. To remove the TDS reduction filter, turn to the left 1/4 turn. Pull down to remove. 3. Disconnect reject tubing by pushing in the white collet on plastic fitting to release the tubing (see page 9).
2 T ubing is secured in. Grey Collet T ube Push tubing straight in as far as it will go. 1 Pull tubing straight out. 2 T o Attach T ubing 1 Push in grey collet to release tubing. T o Release T ubing ‘Push-In’ Tubing Connector (John Guest® Fitting) This product is outfitted with user friendly “Push In” connectors.
4 3 2 9 10 5 8 7 1 6 Item # Description STM150 TSR150-2 1 Sediment Filter (S) 55997-01 55997-01 2 Chlorine Reduction Filter (C) 55995-01 55995-01 3 TDS Reduction Filter (M) 55987-07 55987-07 4 Ion Med.
© 2007 3M Company. All rights reserved. CUNO Incorporated 400 Research Parkway Meriden, CT 06450, USA Toll Free: 1-888-218-CUNO Worldwide: 203-237-5541 Fax: 203-238-8701 www.cunofoodservice.com • www.cuno.com a 3M company CUNO and ScaleGard are trademarks of 3M Company used under license.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il 3M STM150 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del 3M STM150 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso 3M STM150 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul 3M STM150 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il 3M STM150, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del 3M STM150.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il 3M STM150. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo 3M STM150 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.