Manuale d’uso / di manutenzione del prodotto A100 del fabbricante Eagle
Vai alla pagina of 16
EA GLE I n s t a l l a t i o n, Op er a t i on an d M a in t en an c e I n s tru c ti o ns EA G L E M O D E L A 1 00 A N S I P U M P S Lubrication information is in Section III-A, Item 1b.
2 SECTION I—GENERAL Introduction ................................................................................................................................................................. 3 I-A Importance of Instructions .....................
3 Introduction This instruction manual is intended to assist those involved with the installation, operation and maintenance of Eagle Model A100 pumps. It is recommended that this manual be thoroughly reviewed prior to installing or performing any work on the pump or motor .
4 II-C. Lev eling and Gr outing of Baseplate Initial Alignment Chec k 1. Put the unit in place on wedges located at four points as shown in F ig . 2. Some long installations may require additional wedges near center of bedplate. 2. Adjust wedges to level unit (appro ximately), placing unit between ” and 1” above foundation.
5 PRIOR TO COUPLING DRIVER TO PUMP , ROT A TION OF DRIVER SHOULD BE CHECKED! Serious damage can result if pump is rotated in wrong direction. Once motor rotation is checked, connect coupling , following the manufacturer ’s instructions. If a coupling guard is furnished with the unit, ensure that it is securely fastened in place.
6 b. A high quality turbine type oil with rust and oxidation inhibitors should be used. Under normal operating conditions, an oil of 300 SSU viscosity at 100° F . (approximately SAE 20) should be used. Fill oiler bottle and replace in oiler housing .
7 SECTION V— DIS ASSEMBL Y AND REASSEMBL Y V -A. Disassembly (refer to Sectional V iews in Part VI) 1. Prepare pump for disassembly as follows: a. Lock out power supply to motor . b. Shut off valves controlling flow to and from pump. c. Flush pump of all corrosive or toxic liquid, if required.
8 4. On S, M and L models, insert retaining ring (361A) into groove in bearing housing (134A). Flat side of retaining ring must be against bearing (112A). On X units, slide bearing end cover (109A) and gasket (360C) on shaft. Ensure the “top ” of end cover (109A) lines up with the “top ” of bearing housing (134A), check scribe marks.
9 13. Place casing gasket (351) against shoulder in casing . 14. Slide the pullout assembly into the casing (100). Drain slot in stuffing box cover (184) should line up with drain connection in casing. Install frame–to–casing bolts (370) and tighten evenly while rotating shaft (122) by hand.
10 101 106 1 12A 126 168A 261 332A 333A 351 360C 360D 412A 469D 496 1 1 set 1 1 1 1 1 1 1 1 1 1 1 1 Impeller Stuffing Box Packing (2) Ball Bearing-Outboard.
11 Mod el A 1 0 0 S, M, L Ass embl y Vie w of 8” P umps Only 100 239 105 106 412A 469D 101 351 122A 355 353 107 333A 370D 1 13A 496 361A 168A 123 210 261 126 370H 184 370 228A 1 12A 134A 332A 136 &a.
12 Mod el A 1 0 0 M , L 132 370 184 168A 360D 496 108 107 355 353 123 113A 228A 370C 134A 136 & 382 332A 112A 370D 361A 370E 370H 126 122A 210 333A 106 370F 131 239 105 469D 412A 106 101 351 100.
13 Mod el A 1 0 0 X 101 412A 469D 106 105 184 351 100 370H 239 355 107 370 370E 131 228A 370F 106 333A 469B 353 1 13A 168A 123 261 126 108 210 132 122A 360D 370D 371C 109A 332A 136 & 382 496A 134A.
14 Causes & Corrective Measures 1. Pump not primed or properly vented—check that casing and suction pipe are completely filled with liquid. 2. Speed too low—check whether motor wiring is correct and receives full voltage or turbine receives full steam pressure.
15 SEC T ION VII I — ORDERI NG S P ARE P ART S VIII-B. Instr uctions for Or dering Spare Par ts Repair orders will be handled with the minimum of delay if the following directions are followed: 1. Give model number , size of pump, and serial number .
EA GLE EA GL E P UMP & C OM P RE SSO R L T D . 7025 - 5 Street S.E., Calgar y , AB T2H 2G2 Canada ANSI Centrifugal Pumps Multistage Horizontal Pumps V er tical Sump Pumps R otar y Scr ew Compressor Air/Gas Dr y er s www .
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Eagle A100 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Eagle A100 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Eagle A100 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Eagle A100 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Eagle A100, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Eagle A100.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Eagle A100. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Eagle A100 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.